Cuff-less and continuous blood pressure measurement based on pulse transit time from carotid and toe photoplethysmograms

被引:3
|
作者
Zuhair Sameen A. [1 ]
Jaafar R. [2 ]
Zahedi E. [3 ]
Kok Beng G. [2 ]
机构
[1] Department of Medical Instrumentation Engineering Techniques, College of Medical Techniques, Al-Farahidi University, Baghdad
[2] Department of Electrical Electronic and Systems Engineering, Faculty of Engineering, and Built Environment, University Kebangsaan Malaysia (UKM), Bangi
[3] SwifTek Consulting, Vancouver
来源
关键词
blood pressure (BP); electrocardiogram (ECG); photoplethysmogram (PPG); Pulse transit time (PTT); pulse wave velocity (PWV); system identification (SI);
D O I
10.1080/03091902.2022.2077998
中图分类号
学科分类号
摘要
Blood pressure (BP) is a vital health parameter that varies throughout the day. As a single reading of high BP may not indicate hypertension, continuous monitoring of BP is usually recommended by medical doctors to confirm the diagnosis of hypertension. In the last few decades, researchers have investigated cuff-less and continuous BP measurements based on pulse transit time (PTT). The main purpose of this research is to develop an autoregressive (ARX) system identification (SI)-based PTT calculation model using two PPG signals acquired from carotid and toe. The signals were recorded from 65 subjects with an age range between 20 and 60 years. The results of the study have been validated in two stages. The first validation comprised the estimated BP from PTT using SI compared to the measured BP using the cuff-based method for all subjects. The results of the estimated BP using the proposed method compared to the measured BP obtained using the standard BP cuff measurement method are highly correlated to both systolic blood pressure (R 2 = 0.8132) and diastolic blood pressure (R 2 = 0.8357). The second validation consisted of comparing PTT values using system identification to the results of the PTT derived from the ECG–PPG method. The results showed that both methods are highly correlated (R 2 = 0.7808), and there is no significant difference between them (p < 0.05) with a slightly better PTT estimation related to DBP in the proposed method. Our results have proven that the PTT obtained from the carotid PPG and toe PPG using the system identification approach yielded SBP and DBP estimations that are consistent with the values of the conventional BP cuff method. The newly proposed method has the advantage of being cuff-less and able to provide continuous BP measurements. © 2022 Informa UK Limited, trading as Taylor & Francis Group.
引用
收藏
页码:567 / 589
页数:22
相关论文
共 50 条
  • [21] Cuff-Less High-Accuracy Calibration-Free Blood Pressure Estimation Using Pulse Transit Time
    Kachuee, Mohamad
    Kiani, Mohammad Mahdi
    Mohammadzade, Hoda
    Shabany, Mahdi
    2015 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2015, : 1006 - 1009
  • [22] Cuff-Less PPG based Continuous Blood Pressure Monitoring - A Smartphone based Approach
    Gaurav, Aman
    Maheedhar, Maram
    Tiwari, Vijay N.
    Narayanan, Rangavittal
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 607 - 610
  • [23] Cuff-less Blood Pressure Measurement Based on Deep Convolutional Neural Network
    Liu, ZengDing
    Miao, Fen
    Wang, Ruxin
    Liu, Jikui
    Wen, Bo
    Li, Ye
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 3775 - 3778
  • [24] Cuff-less Blood Pressure measurement from Wireless ECG and PPG signals
    Dave, Tejal
    Pandya, Utpal
    Joshi, Maulin
    2021 IEEE INTERNATIONAL SYMPOSIUM ON SMART ELECTRONIC SYSTEMS (ISES 2021), 2021, : 33 - 37
  • [25] Continuous blood pressure measurement based on pulse transit time: a comparison to ambulatory blood pressure measurement
    Kuechler, G.
    Gehring, J.
    Wesely, M.
    Thimel, K.
    Haberl, R.
    EUROPEAN HEART JOURNAL, 2016, 37 : 1267 - 1267
  • [26] Design and Development of Continuous Cuff-less Blood Pressure Monitoring Devices
    Griggs, Devon
    Sharma, Manuja
    Naghibi, Arian
    Wallin, Colton
    Ho, Victor
    Barbosa, Karinne
    Ghirmai, Tadesse
    Cao, Hung
    Krishnan, Sandeep K.
    2016 IEEE SENSORS, 2016,
  • [27] Posture-Dependent Variability in Wrist Ballistocardiogram-Photoplethysmogram Pulse Transit Time: Implication to Cuff-Less Blood Pressure Tracking
    Shin, Sungtae
    Mousavi, Azin
    Lyle, Sophia
    Jang, Elisabeth
    Yousefian, Peyman
    Mukkamala, Ramakrishna
    Jang, Dae-Geun
    Kwon, Ui Kun
    Kim, Youn Ho
    Hahn, Jin-Oh
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2022, 69 (01) : 347 - 355
  • [28] An Armband Wearable Device for Overnight and Cuff-Less Blood Pressure Measurement
    Zheng, Ya-Li
    Yan, Bryan P.
    Zhang, Yuan-Ting
    Poon, Carmen C. Y.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (07) : 2179 - 2186
  • [29] Continuous Noninvasive blood pressure measurement by pulse transit time
    Fung, P
    Dumont, G
    Ries, C
    Mott, C
    Ansermino, M
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 738 - 741
  • [30] Continuous Systolic Blood Pressure Measurement Based on Improved Pulse Transit Time
    Xie, Meng
    Yang, Bo
    Chen, Cailian
    Guan, Xinping
    Hong, Peijun
    PROCEEDINGS OF THE 35TH CHINESE CONTROL CONFERENCE 2016, 2016, : 5173 - 5178