Cuff-less and continuous blood pressure measurement based on pulse transit time from carotid and toe photoplethysmograms

被引:3
|
作者
Zuhair Sameen A. [1 ]
Jaafar R. [2 ]
Zahedi E. [3 ]
Kok Beng G. [2 ]
机构
[1] Department of Medical Instrumentation Engineering Techniques, College of Medical Techniques, Al-Farahidi University, Baghdad
[2] Department of Electrical Electronic and Systems Engineering, Faculty of Engineering, and Built Environment, University Kebangsaan Malaysia (UKM), Bangi
[3] SwifTek Consulting, Vancouver
来源
关键词
blood pressure (BP); electrocardiogram (ECG); photoplethysmogram (PPG); Pulse transit time (PTT); pulse wave velocity (PWV); system identification (SI);
D O I
10.1080/03091902.2022.2077998
中图分类号
学科分类号
摘要
Blood pressure (BP) is a vital health parameter that varies throughout the day. As a single reading of high BP may not indicate hypertension, continuous monitoring of BP is usually recommended by medical doctors to confirm the diagnosis of hypertension. In the last few decades, researchers have investigated cuff-less and continuous BP measurements based on pulse transit time (PTT). The main purpose of this research is to develop an autoregressive (ARX) system identification (SI)-based PTT calculation model using two PPG signals acquired from carotid and toe. The signals were recorded from 65 subjects with an age range between 20 and 60 years. The results of the study have been validated in two stages. The first validation comprised the estimated BP from PTT using SI compared to the measured BP using the cuff-based method for all subjects. The results of the estimated BP using the proposed method compared to the measured BP obtained using the standard BP cuff measurement method are highly correlated to both systolic blood pressure (R 2 = 0.8132) and diastolic blood pressure (R 2 = 0.8357). The second validation consisted of comparing PTT values using system identification to the results of the PTT derived from the ECG–PPG method. The results showed that both methods are highly correlated (R 2 = 0.7808), and there is no significant difference between them (p < 0.05) with a slightly better PTT estimation related to DBP in the proposed method. Our results have proven that the PTT obtained from the carotid PPG and toe PPG using the system identification approach yielded SBP and DBP estimations that are consistent with the values of the conventional BP cuff method. The newly proposed method has the advantage of being cuff-less and able to provide continuous BP measurements. © 2022 Informa UK Limited, trading as Taylor & Francis Group.
引用
收藏
页码:567 / 589
页数:22
相关论文
共 50 条
  • [1] Cuff-less blood pressure measurement with pulse transit time: The importance of rigorous assessment
    van Helmond, Noud
    Plante, Timothy B.
    JOURNAL OF CLINICAL HYPERTENSION, 2021, 23 (01): : 71 - 72
  • [2] Cuff-Less Continuous Blood Pressure Monitoring System Using Pulse Transit Time Techniques
    Zaki, Wan Suhaimizan Wan
    Correia, Ricardo
    Korposh, Serhiy
    Hayes-Gill, Barrie R.
    Morgan, Stephen P.
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2016, 8 (01): : 51 - 57
  • [3] Cuff-less and noninvasive measurements of arterial blood pressure by pulse transit time
    Poon, C. C. Y.
    Zhang, Y. T.
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 5877 - 5880
  • [4] CUFF-LESS BLOOD PRESSURE MEASUREMENT USING THE PULSE TRANSIT TIME - A COMPARISON TO CUFF-BASED OSCILLOMETRIC 24 HOUR BLOOD PRESSURE MEASUREMENT IN CHILDREN
    Hulpke-Wette, M.
    Goehler, A.
    Hofmann, E.
    Kuechler, G.
    JOURNAL OF HYPERTENSION, 2018, 36 : E73 - E73
  • [5] Wearable Cuff-Less Blood Pressure Estimation at Home via Pulse Transit Time
    Ganti, Venu G.
    Carek, Andrew M.
    Nevius, Brandi N.
    Heller, J. Alex
    Etemadi, Mozziyar
    Inan, Omer T.
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2021, 25 (06) : 1926 - 1937
  • [6] Implementation of Cuff-less Continuous Blood Pressure Measurement System Based on Android
    Xu, Lisheng
    Guo, Xu
    Yang, Feifei
    Yin, Sainan
    Zhang, Xibin
    Meng, Max Q. -H.
    PROCEEDING OF THE IEEE INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION, 2012, : 552 - 556
  • [7] Cuff-less blood pressure measurement using pulse arrival time and a Kalman filter
    Zhang, Qiang
    Chen, Xianxiang
    Fang, Zhen
    Xue, Yongjiao
    Zhan, Qingyuan
    Yang, Ting
    Xia, Shanhong
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2017, 27 (02)
  • [8] Continuous Cuff-less Blood Pressure Monitoring based on the Pulse Arrival Time Approach: The Impact of Posture
    Muehlsteff, J.
    Aubert, X. A.
    Morren, G.
    2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vols 1-8, 2008, : 1691 - 1694
  • [9] Cuff-Less Methods for Blood Pressure Measurement
    Gan, Liangzhi
    Wang, Chen
    Liu, Haikuan
    Zhang, Lei
    2019 CHINESE AUTOMATION CONGRESS (CAC2019), 2019, : 4926 - 4930
  • [10] EDifferential Pulse Arrival Time: A Novel Approach to Continuous Cuff-less Blood Pressure Monitoring
    Pandit, Jay A.
    Miller, Kyle
    Wu, Jung-en
    Connell, Sean D.
    Shah, Sanjiv
    CIRCULATION, 2016, 134