Pose estimation of mobile-bearing total knee arthroplasty using X-ray fluoroscopic images and 3D knematic analysis

被引:0
|
作者
Yamazaki, Takaharu [1 ]
Futai, Kazuma [2 ]
Tomita, Tetsuya [2 ]
Sato, Yoshinobu [3 ]
Yoshikawa, Hideki [4 ]
Tamura, Shinichi [1 ]
Sugamoto, Kazuomi [2 ,5 ]
机构
[1] The Center for Advanced Medical Engineering and Informatics, Osaka University, Japan
[2] Division of Orthopaedic Biomaterial Science, Osaka University Graduate School of Medicine, Japan
[3] Department of Radiology, Osaka University Graduate School of Medicine, Japan
[4] Department of Orthopaedics, Osaka University Graduate School of Medicine, Japan
[5] NBL Research Laboratory, Japan
关键词
Orthopedics - Computer aided analysis - Computer aided design - Knee prostheses - Physiological models - Fluorescent screens - Implants (surgical) - Polyethylenes - Arthroplasty - Image registration - Image analysis;
D O I
暂无
中图分类号
学科分类号
摘要
To achieve 3D kinematic analysis of total knee arthroplasty (TKA), 2D 3D image registration techniques, which use X-ray fluoroscopic images and computer aided design (CAD) model of the knee implant, have attracted attention in recent years. These techniques could provide information regarding the movement of radiopaque femoral and tibial components but could not provide information of radiolucent polyethylene insert, because the insert silhouette on X-ray image did not appear clearly. Therefore, it was difficult to obtain 3D kinemaitcs of the polyethylene insert, particularly the mobile-bearing insert that move on the tibial component. This study presents a technique and the accuracy for 3D kinematic analysis of the mobile-bearing insert in TKA using X-ray fluoroscopy, and finally performs clinical applications. For a 3D pose estimation technique of the mobile-bearing insert in TKA using X-ray fluoroscopy, tantalum beads and CAD model with its beads are utilized, and the 3D pose of the insert model is estimated using a feature-based 2D 3D image registration technique. In order to validate the accuracy of the present technique, experiments including computer simulation test were performed. The results showed the pose estimation accuracy was sufficient for analyzing mobile-bearing TKA kinematics, and the estimation errors were within 1. 0 mm and 1. 0 degree except for translation parameter perpendicular to X-ray fluoroscopic images. In the clinical applications, seven patients with the mobile-bearing TKA in deep knee bending motion were studied and analyzed. Consequently, the present technique enables us to better understand mobile-bearing TKA kinematics, and this type of evaluation was thought to be helpful for improving implant design and optimizing TKA surgical techniques.
引用
收藏
页码:703 / 711
相关论文
共 50 条
  • [31] Mobile-bearing versus fixed-bearing total knee arthroplasty: a meta-analysis of randomized controlled trials.
    Ashraf T. Hantouly
    Abdulaziz F. Ahmed
    Osama Alzobi
    Ammar Toubasi
    Motasem Salameh
    Aissam Elmhiregh
    Shamsi Hameed
    Ghalib O. Ahmed
    Abtin Alvand
    Mohammed Al Ateeq Al Dosari
    European Journal of Orthopaedic Surgery & Traumatology, 2022, 32 : 481 - 495
  • [32] Mobile-bearing versus fixed-bearing total knee arthroplasty: a meta-analysis of randomized controlled trials.
    Hantouly, Ashraf T.
    Ahmed, Abdulaziz F.
    Alzobi, Osama
    Toubasi, Ammar
    Salameh, Motasem
    Elmhiregh, Aissam
    Hameed, Shamsi
    Ahmed, Ghalib O.
    Alvand, Abtin
    Al Dosari, Mohammed Al Ateeq
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2022, 32 (03): : 481 - 495
  • [33] Biomechanical Comparison of Fixed- and Mobile-Bearing for Unicomparmental Knee Arthroplasty Using Finite Element Analysis
    Kwon, Oh-Ryong
    Kang, Kyoung-Tak
    Son, Juhyun
    Kwon, Sae-Kwang
    Jo, Seung-Bae
    Suh, Dong-Suk
    Choi, Yun-Jin
    Kim, Ho-Joong
    Koh, Yong-Gon
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2014, 32 (02) : 338 - 345
  • [34] Generation of Fluoroscopic 3D Images Using Single X-Ray Projections On Realistic Modified XCAT Phantom Data
    Mishra, P.
    Li, R.
    St James, S.
    Yue, Y.
    Mak, R.
    Berbeco, R.
    Lewis, J.
    MEDICAL PHYSICS, 2012, 39 (06) : 3681 - 3681
  • [35] Fluoroscopic Intraoperative Images Produce Higher Image Quality and Decrease Total Radiation Exposure Compared to Radiographic X-ray Images in Patients After Primary Total Knee Arthroplasty
    Graulich, Tilman
    Gerhardy, Julius
    Oergel, Marcus
    Omar-Pacha, Tarek
    Omar, Mohamed
    Krettek, Christian
    Guenther, Daniel
    IN VIVO, 2020, 34 (05): : 2521 - 2526
  • [36] Changes in Lower Extremity 3-Dimensional Load-Bearing Axes Before and After Mobile-Bearing Total Knee Arthroplasty
    Ishii, Yoshinori
    Noguchi, Hideo
    Takeda, Mitsuhiro
    Sato, Junko
    Ezawa, Nobukazu
    Toyabe, Shin-Ichi
    JOURNAL OF ARTHROPLASTY, 2012, 27 (06): : 1203 - 1209
  • [37] Using standard X-ray images to create 3D digital bone models and patient-matched guides for aiding implant positioning and sizing in total knee arthroplasty
    Masse, Vincent
    Ghate, Raju S.
    COMPUTER ASSISTED SURGERY, 2021, 26 (01) : 31 - 40
  • [38] Unsupervised registration of 3D knee implant components to biplanar X-ray images
    Nguyen, Dac Cong Tai
    Benameur, Said
    Mignotte, Max
    Lavoie, Frederic
    BMC MEDICAL IMAGING, 2023, 23 (01)
  • [39] Unsupervised registration of 3D knee implant components to biplanar X-ray images
    Dac Cong Tai Nguyen
    Said Benameur
    Max Mignotte
    Frédéric Lavoie
    BMC Medical Imaging, 23
  • [40] Effects of posterior condylar offset and posterior tibial slope on mobile-bearing total knee arthroplasty using computational simulation
    Kang, Kyoung-Tak
    Kwon, Sae Kwang
    Son, Juhyun
    Kwon, Oh-Ryong
    Lee, Jun-Sang
    Koh, Yong-Gon
    KNEE, 2018, 25 (05): : 903 - 914