One-step copper deposition-induced signal amplification for multiplex bacterial infection diagnosis on a lateral flow immunoassay device

被引:1
|
作者
Chien, Yuh-Shiuan [1 ]
Tsai, Tsung-Ting [2 ,3 ]
Lin, Jia-Hui [4 ]
Chang, Chien-Cheng [1 ]
Chen, Chien-Fu [1 ,5 ]
机构
[1] Natl Taiwan Univ, Inst Appl Mech, Taipei 106, Taiwan
[2] Chang Gung Mem Hosp, Dept Orthopaed Surg, Taoyuan 333, Taiwan
[3] Chang Gung Univ, Coll Med, Taoyuan 333, Taiwan
[4] Natl Univ Kaohsiung, Dept Appl Chem, Kaohsiung 811, Taiwan
[5] Natl Taiwan Univ, Grad Sch Adv Technol, Taipei 106, Taiwan
来源
关键词
Lateral flow immunoassay; Copper deposition; Point-of-care device; One-step signal amplification; Staphylococcus aureus; Pseudomonas aeruginosa; PAPER; NANOPARTICLES;
D O I
10.1016/j.bios.2024.116849
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The lateral flow immunoassay (LFIA) is predominant in rapid diagnostic tests owing to its cost-effectiveness and operational simplicity. However, the conventional LFIA exhibits limited sensitivity and is susceptible to human variance for the result readout, impacting result interpretation. In this study, we introduced a novel one-step copper deposition-induced signal amplification lateral flow immunoassay (osa-LFIA) that markedly enhances the detection sensitivity for Staphylococcus aureus (protein A) and Pseudomonas aeruginosa (exotoxin A). Utilizing gold nanoparticles (AuNPs) as a catalyst, this approach employs ascorbic acid to reduce Cu2+ to Cu-0, depositing on AuNPs at the test line and amplifying the signal. A user-friendly design features a three-dimensional paper structure incorporating pre-dried reagents, enabling a streamlined, efficient testing process. The osa-LFIA significantly lowers detection limits to 3 ng mL(-1) for protein A and 10 ng mL(-1) for exotoxin A, offering a tenfold improvement over conventional LFIA. Additionally, we developed a portable grayscale detection device, achieving less than 10% error in quantitative analysis compared to the data acquired and analyzed in the lab. This entire process, from detection to signal amplification, is completed in just 20 min. For the clinical trial, we utilized the osa-LFIA to test synovial fluid samples infected with Staphylococcus aureus. We also successfully detected different concentrations of the exotoxin A in parallel, with a recovery value of 96%-110%. Our findings demonstrate the osa-LFIA's potential as a rapid, highly sensitive, and simple-to-use diagnostic tool for detecting various pathogens, significantly advancing the field of rapid diagnostic testing.
引用
收藏
页数:10
相关论文
共 42 条
  • [1] Copper deposition-induced efficient signal amplification for ultrasensitive lateral flow immunoassay
    Tian, Meiling
    Lei, Lingli
    Xie, Wenyue
    Yang, Qimeng
    Li, Chang Ming
    Liu, Yingshuai
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 282 : 96 - 103
  • [2] PEI-Mediated Copper Deposition Strategy for Optical Signal Amplification on Lateral Flow Immunoassay Platform
    Li, Mengyao
    Wang, Yao
    Xu, Hong
    ACS APPLIED OPTICAL MATERIALS, 2025, 3 (01): : 1 - 5
  • [3] Development of a One-Step Lateral Flow Immunoassay for Rapid Detection of Icariin
    Qu, Huihua
    Qu, Baoping
    Cheng, Jinjun
    Zhang, Yue
    Zeng, Wenhao
    Wang, Qingguo
    Kong, Hui
    Zhao, Yan
    CURRENT PHARMACEUTICAL ANALYSIS, 2018, 14 (02) : 101 - 107
  • [4] Development of a multiplex and sensitive lateral flow immunoassay for the diagnosis of periprosthetic joint infection
    Tsai, Tsung-Ting
    Huang, Tse-Hao
    Ho, Natalie Yi-Ju
    Chen, Yu-Pei
    Chen, Chung-An
    Chen, Chien-Fu
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [5] Development of a multiplex and sensitive lateral flow immunoassay for the diagnosis of periprosthetic joint infection
    Tsung-Ting Tsai
    Tse-Hao Huang
    Natalie Yi-Ju Ho
    Yu-Pei Chen
    Chung-An Chen
    Chien-Fu Chen
    Scientific Reports, 9
  • [6] One-Step Detection of Vancomycin in Whole Blood Using the Lateral Flow Immunoassay
    Jung, Yugyung
    Kim, Seonjong
    Kim, Min-Gon
    Lee, Young-Eun
    Shin, Myung-Geun
    Yang, Sung
    BIOSENSORS-BASEL, 2024, 14 (03):
  • [7] Lateral Flow Biosensor for On-Site Multiplex Detection of Viruses Based on One-Step Reverse Transcription and Strand Displacement Amplification
    Lu, Xuewen
    Ding, Kangning
    Fang, Zhiyuan
    Liu, Yilei
    Ji, Tianxing
    Sun, Jian
    Zeng, Zhenling
    He, Limin
    BIOSENSORS-BASEL, 2024, 14 (02):
  • [8] One-step polymerized lanthanide-based polystyrene microsphere for sensitive lateral flow immunoassay
    Li, Zhenhua
    Liu, Qingyun
    Li, Yongfang
    Yuan, Wei
    Li, Fuyou Y.
    JOURNAL OF RARE EARTHS, 2021, 39 (01) : 11 - 18
  • [9] One-step polymerized lanthanide-based polystyrene microsphere for sensitive lateral flow immunoassay
    Zhenhua Li
    Qingyun Liu
    Yongfang Li
    Wei Yuan
    Fuyou Y.Li
    Journal of Rare Earths, 2021, 39 (01) : 11 - 18
  • [10] One-step-immunoassay of procalcitonin enables rapid and accurate diagnosis of bacterial infection
    Oh, Jae-Hwan
    Kwon, Jung-Hyuk
    Kim, Hye-Hyun
    Lee, Jeewon
    RSC ADVANCES, 2021, 11 (35) : 21375 - 21383