Study on minimally invasive blood glucose monitoring detector based on interstitial fluid transdermal extraction

被引:0
|
作者
机构
[1] Li, Dachao
[2] Ji, Yongjie
[3] Liang, Wenshuai
[4] Yu, Haixia
[5] Xu, Kexin
来源
Li, D. (dchli@tju.edu.cn) | 1600年 / Science Press卷 / 34期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [21] MINIMALLY INVASIVE INTERSTITIAL FLUID EXTRACTION TECHNOLOGY TO MEASURE 8-H AVERAGE GLUCOSE LEVELS DURING THE NIGHT
    Uemura, M.
    Suzuki, T.
    Yasuma, T.
    Sato, T.
    Morimoto, A.
    Hosoya, S.
    Suminaka, C.
    Nakajima, H.
    Yano, Y.
    Sumida, Y.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2014, 16 : A79 - A79
  • [22] Interstitial Fluid Biomarkers' Minimally Invasive Monitoring Using Microneedle Sensor Arrays
    Li, Jinze
    Lu, Huiting
    Wang, Yeyu
    Yang, Shuangshuang
    Zhang, Yufan
    Wei, Wei
    Qiao, YuChun
    Dai, Wenhao
    Ge, Rujiao
    Dong, Haifeng
    ANALYTICAL CHEMISTRY, 2022, 94 (02) : 968 - 974
  • [23] Structural development of a minimally invasive sensor chip for blood glucose monitoring
    Kaimori, Shingo
    Kitamura, Takahiko
    Ichino, Moriyasu
    Hosoya, Toshifumi
    Kurusu, Fumiyo
    Ishikawa, Tomoko
    Nakamura, Hideaki
    Gotoh, Masao
    Karube, Isao
    ANALYTICA CHIMICA ACTA, 2006, 573 : 104 - 109
  • [24] Porous Platinum Black-Coated Minimally Invasive Microneedles for Non-Enzymatic Continuous Glucose Monitoring in Interstitial Fluid
    Chinnadayyala, Somasekhar R.
    Cho, Sungbo
    NANOMATERIALS, 2021, 11 (01) : 1 - 15
  • [25] Minimally invasive technique for measuring transdermal glucose with a fluorescent biosensor
    Brown, Sheniqua
    Zambrana, Paige N.
    Ge, Xudong
    Bagdure, Dayanand
    Stinchcomb, Audra L.
    Rao, Govind
    Tolosa, Leah
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (27) : 7249 - 7260
  • [26] Evaluating glucose area under the curve (AUC) measurements by minimally invasive interstitial fluid extraction technology: comparison to AUC measured by continuous glucose monitor
    Ugi, S.
    Nishio, Y.
    Morino, K.
    Yoshimoto, S.
    Kusunoki, C.
    Sato, T.
    Okada, S.
    Hagino, K.
    Kikkawa, Y.
    Kojima, J.
    Watanabe, T.
    Nakajima, H.
    Kashiwagi, A.
    Maegawa, H.
    DIABETOLOGIA, 2011, 54 : S412 - S412
  • [27] Minimally invasive technique for measuring transdermal glucose with a fluorescent biosensor
    Sheniqua Brown
    Paige N. Zambrana
    Xudong Ge
    Dayanand Bagdure
    Audra L. Stinchcomb
    Govind Rao
    Leah Tolosa
    Analytical and Bioanalytical Chemistry, 2018, 410 : 7249 - 7260
  • [28] A novel minimally invasive method to detect glucose concentration without blood extraction
    Li, Dachao
    Huang, Xian
    Yu, Haixia
    Zhang, Zengfu
    Huang, Fuxiang
    Xu, Kexin
    Hu, Xiaotang
    2006 1ST IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS, VOLS 1-3, 2006, : 1185 - +
  • [29] Monitoring blood glucose with microdialysis of interstitial fluid in critically ill children
    Vlasselaers, Dirk
    Schau, Lukas
    van den Heuvel, Ingeborg
    Mader, Julia
    Bodenlenz, Manfred
    Suppan, Maria
    Wouters, Pieter
    Ellmeree, Martin
    Van den Berghe, Greet
    CLINICAL CHEMISTRY, 2007, 53 (03) : 536 - 537
  • [30] Measurement of glucose concentration in interstitial fluid - an alternative or a supplement to conventional blood glucose monitoring?
    Kublin, Oskar
    Stepien, Mariusz
    CLINICAL DIABETOLOGY, 2019, 8 (02): : 121 - 126