Evaluating Alternative Registration Planes in Imageless, Computer-Assisted Navigation Systems for Direct Anterior Total Hip Arthroplasty

被引:0
|
作者
Farey, John E. [1 ]
Chai, Yuan [1 ,2 ]
Xu, Joshua [3 ]
Maes, Vincent [1 ,4 ]
Sadeghpour, Ameneh [5 ]
Baker, Neri A. [5 ]
Vigdorchik, Jonathan M. [6 ]
Walter, William L. [1 ,3 ]
机构
[1] Univ Sydney, Fac Med & Hlth, Sydney Musculoskeletal Hlth, Kolling Inst,Northern Clin Sch, Camperdown, NSW 2064, Australia
[2] South China Univ Technol, Inst Future Hlth, Guangzhou 511442, Peoples R China
[3] Royal North Shore Hosp, Dept Orthoped & Traumat Surg, St Leonards, NSW 2065, Australia
[4] Univ Hosp Leuven, Dept Orthoped Surg, Herestr 49, B-3000 Leuven, Belgium
[5] Navbit, Innovat Dept, Sydney, NSW 2000, Australia
[6] Hosp Special Surg, Adult Reconstruct & Joint Replacement Serv, New York, NY 10021 USA
关键词
computer assisted surgery; imageless navigation; optical sensor; total hip arthroplasty; acetabular orientation; registration plane; implant accuracy; ACETABULAR COMPONENT; DISLOCATION; REVISION; ACCURACY; POSITION; RISK; WEAR;
D O I
10.3390/s24217092
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
(1) Background: Imageless computer navigation systems have the potential to improve the accuracy of acetabular cup position in total hip arthroplasty (THA). Popular imageless navigation methods include locating the patient in a three-dimensional space (registration method) while using a baseline to angle the acetabular cup (reference plane). This study aims to compare the accuracy of different methods for determining postoperative acetabular cup positioning in THA via the direct anterior approach. (2) Methods: Fifty-one participants were recruited. Optical and inertial sensor imageless navigation systems were used simultaneously with three combinations of registration methods and reference planes: the anterior pelvic plane (APP), the anterior superior iliac spine (ASIS) and the table tilt (TT) method. Postoperative acetabular cup position, inclination, and anteversion were assessed using CT scans. (3) Results: For inclination, the mean absolute error (MAE) was lower using the TT method (2.4 degrees +/- 1.7 degrees) compared to the ASIS (2.8 degrees +/- 1.7 degrees, p = 0.17) and APP method (3.7 degrees +/- 2.1 degrees, p < 0.001). For anteversion, the MAE was significantly lower for the TT method (2.4 degrees +/- 1.8 degrees) in contrast to the ASIS (3.9 degrees +/- 3.2 degrees, p = 0.005) and APP method (9.1 degrees +/- 6.2 degrees, p < 0.001). (4) Conclusion: A functional reference plane is superior to an anatomic reference plane to accurately measure intraoperative acetabular cup inclination and anteversion in THA using inertial imageless navigation systems.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Defining the Errors in the Registration Process During Imageless Computer Navigation in Total Knee Arthroplasty: A Cadaveric Study
    Davis, Edward T.
    Pagkalos, Joseph
    Gallie, Price A. M.
    Macgroarty, Kelly
    Waddell, James P.
    Schemitsch, Emil H.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (04): : 698 - 701
  • [32] Computer-Assisted Total Knee Arthroplasty: Is There a Difference Between Image-Based and Imageless Techniques?
    Tabatabaee, Reza M.
    Rasouli, Mohammad R.
    Maltenfort, Mitchell G.
    Fuino, Robert
    Restrepo, Camilo
    Oliashirazi, Ali
    JOURNAL OF ARTHROPLASTY, 2018, 33 (04): : 1076 - 1081
  • [33] Large-console, Imageless Computer-assisted Navigation Vs Accelerometer Based Portable Navigation Technique of Total Knee Arthroplasty - a Prospective Randomized Study
    Malhotra, Rajesh
    Swamy, Arun M.
    Gautam, Deepak
    Manhas, Vikrant
    Digge, Vijay K.
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2021, 233 (05) : E135 - E135
  • [34] Experience with computer-assisted navigation for total knee arthroplasty in a community setting
    Carter, Ralph E., III
    Rush, Paul F.
    Smid, John A.
    Smith, Whitney L.
    JOURNAL OF ARTHROPLASTY, 2008, 23 (05): : 707 - 713
  • [35] The cost-effectiveness of computer-assisted navigation in total knee arthroplasty
    Novak, Erik J.
    Silverstein, Marc D.
    Bozic, Kevin J.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (11): : 2389 - 2397
  • [36] DETECTION OF LOOSENING IN TOTAL HIP ARTHROPLASTY - STEREOPHOTOGRAMMETRIC COMPUTER-ASSISTED METHOD
    HUNTER, JC
    BAUMRIND, S
    GENANT, HK
    ROSS, SE
    MURRAY, WR
    INVESTIGATIVE RADIOLOGY, 1978, 13 (05) : 387 - 387
  • [38] Pin Site Complications Associated With Computer-Assisted Navigation in Hip and Knee Arthroplasty
    Kamara, Eli
    Berliner, Zachary P.
    Hepinstall, Matthew S.
    Cooper, H. John
    JOURNAL OF ARTHROPLASTY, 2017, 32 (09): : 2842 - 2846
  • [39] Computer-Assisted Navigation in Hip Resurfacing Arthroplasty A Single-Surgeon Experience
    Shields, John S.
    Seyler, Thorsten M.
    Maguire, Cara
    Jinnah, Riyaz H.
    BULLETIN OF THE HOSPITAL FOR JOINT DISEASES, 2009, 67 (02): : 164 - 167
  • [40] Trends in cup position utilizing computer-assisted navigation during total hip arthroplasty: A retrospective observational study
    Mays, Rachel R.
    Benson, Jessica R.
    Muir, Jeffrey M.
    Meftah, Morteza