Simultaneous determination of palladium and rhodium using on-line column enrichment and electrothermal atomic absorption spectrometric detection

被引:0
|
作者
Sánchez Rojas, F. [1 ]
Bosch Ojeda, C. [1 ]
Cano Pavón, J.M. [1 ]
机构
[1] Department of Analytical Chemistry, Faculty of Sciences, University of Málaga, Málaga E-29071, Spain
来源
Journal of Analytical Chemistry | 2009年 / 64卷 / 03期
关键词
Flow injection on-line micro-column pre-concentration was coupled with electrothermal atomic absorption spectrometry (ETAAS) for the simultaneous determination of Rh and Pd in environmental samples. The micro-column contained 1,5-Bis(2-pyridyl)-3-sulphophenyl methylene thiocarbonohydrazide (PSTH) immobilised on an anion-exchange resin (Dowex 1 × 8-200). The sorbent was tested in a micro-column, placed in the auto-sampler arm, at the flow rate 3.1 mL/min. Elution was performed with 2 M HNO3 and the system was optimised with a 60 s pre-concentration time. © 2009 Pleiades Publishing, Ltd;
D O I
暂无
中图分类号
学科分类号
摘要
Journal article (JA)
引用
收藏
页码:241 / 246
相关论文
共 50 条
  • [21] Electrothermal atomic absorption spectrometric determination of selenium in biological fluids with rhodium modifier compared with hydride generation atomic spectrometric techniques
    Tsalev, DL
    Lampugnani, L
    D'Ulivo, A
    Petrov, II
    Georgieva, R
    Marcucci, K
    Zamboni, R
    MICROCHEMICAL JOURNAL, 2001, 70 (02) : 103 - 113
  • [22] Probing mercury species-DNA interactions by capillary electrophoresis with on-line electrothermal atomic absorption spectrometric detection
    Li, Yan
    Jiang, Yan
    Yan, Xiu-Ping
    ANALYTICAL CHEMISTRY, 2006, 78 (17) : 6115 - 6120
  • [23] Simultaneous determination of palladium, platinum and rhodium by on-line column enrichment and HPLC with 5-(2,4-dihydroxyphenylazo)-rhodanine as pre-column derivatization reagent
    Li, Zhigang
    Li, Xuemei
    Hu, Qiufen
    Yin, Jiayuan
    Chzn, Jing
    Yang, Guangyu
    ANNALI DI CHIMICA, 2006, 96 (5-6) : 355 - 363
  • [24] Flow injection atomic absorption spectrometric determination of iodide using an on-line preconcentration technique
    Yebra, MC
    Cespón, RM
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 367 (01): : 24 - 28
  • [25] Flow injection atomic absorption spectrometric determination of iodide using an on-line preconcentration technique
    M. C. Yebra
    R. M. Cespón
    Fresenius' Journal of Analytical Chemistry, 2000, 367 : 24 - 28
  • [26] On-line sorption preconcentration and atomic absorption determination of palladium in solutions
    Bogachiova, LV
    Kovaliov, IA
    Tsizin, GI
    Formanovskii, AA
    Zolotov, YA
    VESTNIK MOSKOVSKOGO UNIVERSITETA SERIYA 2 KHIMIYA, 1999, 40 (02): : 110 - 114
  • [27] Flame atomic absorption spectrometric determination of cobalt after on-line preconcentration
    Lemos, VA
    de Brito, CF
    Ferreira, AC
    Korn, MDA
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2002, 47 (02): : 49 - 54
  • [28] On-line Preconcentration of Pd(II) Using Polyamine Silica Gel Filled Mini Column for Flame Atomic Absorption Spectrometric Determination
    Sivrikaya, Sezen
    Karsli, Bulent
    Imamoglu, Mustafa
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH, 2017, 11 (5-6) : 579 - 590
  • [29] On-line Preconcentration of Pd(II) Using Polyamine Silica Gel Filled Mini Column for Flame Atomic Absorption Spectrometric Determination
    Sezen Sivrikaya
    Bülent Karslı
    Mustafa Imamoglu
    International Journal of Environmental Research, 2017, 11 : 579 - 590
  • [30] On-line preconcentration system coupled to electrothermal atomic absorption spectrometry for the simultaneous determination of bismuth, cadmium, and lead in urine
    Sung, YH
    Huang, SD
    ANALYTICA CHIMICA ACTA, 2003, 495 (1-2) : 165 - 176