Closed form optimal solution of a tuned liquid column damper responding to earthquake

被引:0
|
作者
Mechanical engineering department, Ferdowsi University of Mashhad, Iran [1 ]
机构
来源
关键词
Earthquakes - Liquids - Equations of motion - Optimal systems - Degrees of freedom (mechanics);
D O I
暂无
中图分类号
学科分类号
摘要
In this paper the vibration behaviors of a structure equipped with a tuned liquid column damper (TLCD) under a harmonic type of earthquake loading are studied. However, due to inherent nonlinear liquid damping, it is no doubt that a great deal of computational effort is required to search the optimum parameters of the TLCD, numerically. Therefore by linearization the equation of motion of the single degree of freedom structure equipped with the TLCD, the closed form solutions of the TLCD-structure system are derived. To find the reliability of the analytical method, the results have been compared with other researcher and have good agreement. Further, the effects of optimal design parameters such as length ratio and mass ratio on the performance of the TLCD for controlling the responses of a structure are investigated by using the harmonic type of earthquake excitation. Finally, the Citicorp Center which has a very flexible structure is used as an example to illustrate the design procedure for the TLCD under the earthquake excitation.
引用
收藏
相关论文
共 50 条
  • [31] Tuning Performances of Tuned Double Liquid Column/Mass Damper
    Dai, Naxin
    Huang, Dongyang
    Hu, Shengrong
    PROCEEDINGS OF THE SECOND INTERNATIONAL CONFERENCE ON MODELLING AND SIMULATION (ICMS2009), VOL 4, 2009, : 375 - 379
  • [32] PResearch on Tuning Performances of Tuned Liquid Column/Mass Damper
    Huang, Dongyang
    Tan, Ping
    Jiang, Guoping
    PROCEEDINGS OF FIRST INTERNATIONAL CONFERENCE OF MODELLING AND SIMULATION, VOL V: MODELLING AND SIMULATION IN MECHANICS AND MANUFACTURE, 2008, : 384 - 388
  • [33] COMCAST: THE WORLD'S LARGEST TUNED LIQUID COLUMN DAMPER
    Hart, Sara
    ARCHITECTURAL RECORD, 2009, 197 (05) : 173 - 173
  • [34] Innovative modeling of tuned liquid column damper controlled structures
    Di Matteo, Alberto
    Di Paola, Mario
    Pirrotta, Antonina
    SMART STRUCTURES AND SYSTEMS, 2016, 18 (01) : 117 - 138
  • [35] Tuned liquid column ball damper for seismic vibration control
    Gur, Sourav
    Roy, Koushik
    Mishra, Sudib Kumar
    STRUCTURAL CONTROL & HEALTH MONITORING, 2015, 22 (11): : 1325 - 1342
  • [36] Control performance comparison between tuned liquid damper and tuned liquid column damper using real-time hybrid simulation
    Zhu Fei
    Wang Jinting
    Jin Feng
    Lu Liqiao
    Earthquake Engineering and Engineering Vibration, 2019, 18 (03) : 695 - 701
  • [37] Control performance comparison between tuned liquid damper and tuned liquid column damper using real-time hybrid simulation
    Zhu Fei
    Wang Jinting
    Jin Feng
    Lu Liqiao
    Earthquake Engineering and Engineering Vibration, 2019, 18 : 695 - 701
  • [38] Control performance comparison between tuned liquid damper and tuned liquid column damper using real-time hybrid simulation
    Zhu Fei
    Wang Jinting
    Jin Feng
    Lu Liqiao
    EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2019, 18 (03) : 695 - 701
  • [39] Closed-form solutions for the optimal design of lever-arm tuned mass damper inerter (LTMDI)
    Li, Zhenchuan
    Ma, Ruisheng
    Xu, Kun
    Han, Qiang
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2024, 206
  • [40] Closed-form solutions for the optimal design of lever-arm tuned mass damper inerter (LTMDI)
    Li, Zhenchuan
    Ma, Ruisheng
    Xu, Kun
    Han, Qiang
    Mechanical Systems and Signal Processing, 2024, 206