A Compact Wideband Vivaldi Antenna for Non-Invasive Glucose Monitoring

被引:0
|
作者
Yang, Shasha [1 ]
Wang, Yu [1 ]
Gao, Shiwen [1 ]
Zhuang, Yi [1 ]
Wang, Lifeng [1 ]
Yi, Zhenxiang [1 ]
Zhang, Weixun [2 ]
机构
[1] Southeast Univ, Key Lab MEMS, Minist Educ, Nanjing 210096, Peoples R China
[2] China Southern Power Grid Co Ltd, Guangzhou 510000, Peoples R China
基金
中国国家自然科学基金;
关键词
Vivaldi antenna; glucose level; non-destructive detection; linear regression;
D O I
10.3390/mi15111389
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Due to the high gain, wide bandwidth, and directional radiation characteristics of Vivaldi antennas, this paper conducted relevant research on the feasibility of non-destructive blood glucose detection based on Vivaldi antennas. The research included finite element method (FEM) simulation and glucose concentration monitoring. In the simulation stage, the power transmission and reflection characteristics, radiation characteristics, and electric field distribution characteristics of the antenna were described in detail. In the test stage, the S11 response of the antenna to variation in glucose concentration in the range of 0-6.11 mg/mL was measured, including the S11 amplitude and phase. The experimental results show that there is a high linear correlation between the S11 response and glucose concentration, and the sensitivity of the S11 amplitude response to the variation in glucose concentration is close to 0.3445 (dB/(mg/mL)) at 14.2556 GHz, and the sensitivity of the S11 phase response to the variation in glucose concentration is about 0.5652 (degree/(mg/mL)) at 14.37 GHz. In addition, the predicted results of the glucose concentration based on linear regression are discussed.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Non-invasive glucose monitoring technology in diabetes management: A review
    Vashist, Sandeep Kumar
    ANALYTICA CHIMICA ACTA, 2012, 750 : 16 - 27
  • [42] Non-invasive impedance based continuous glucose monitoring system
    Talary, M. S.
    Dewarrat, F.
    Huber, D.
    Falco-Jonasson, L.
    Caduff, A.
    13TH INTERNATIONAL CONFERENCE ON ELECTRICAL BIOIMPEDANCE AND THE 8TH CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY 2007, 2007, 17 : 636 - +
  • [43] NON-INVASIVE METHODS FOR THE MONITORING OF GLUCOSE CONCENTRATION: CHALLENGES AND PERSPECTIVES
    Abdallah, O.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 : A54 - A54
  • [44] Comparative Analysis of Optoelectronic Properties of Glucose for Non-invasive Monitoring
    Garcia-Guzman, Jesus
    Gonzalez-Viveros, Naara
    Cerecedo-Nunez, Hector H.
    EMERGING CHALLENGES FOR EXPERIMENTAL MECHANICS IN ENERGY AND ENVIRONMENTAL APPLICATIONS, 2017, : 55 - 63
  • [45] Non-invasive wearable electrochemical sensors for continuous glucose monitoring
    Ameen, Sameera Sh. Mohammed
    Omer, Khalid M.
    Mansour, Fotouh R.
    Bedair, Alaa
    Hamed, Mahmoud
    ELECTROCHEMISTRY COMMUNICATIONS, 2025, 173
  • [46] Towards a Wearable Non-invasive Blood Glucose Monitoring Device
    Andrews, Joseph Thomas
    Solanki, J.
    Choudhary, Om P.
    Chouksey, S.
    Malvia, N.
    Chaturvedi, P.
    Sen, P.
    INTERNATIONAL CONFERENCE ON RECENT TRENDS IN PHYSICS (ICRTP 2012), 2012, 365
  • [47] New light upon non-invasive blood glucose monitoring
    Davies-Shaw, D.
    Davies, N.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS II, 2006, 6078
  • [48] Non-invasive monitoring of blood glucose in critically ill patients
    Weinstein, A.
    Herzenstein, O.
    Gabis, E.
    Singer, P.
    DIABETOLOGIA, 2008, 51 : S430 - S430
  • [49] Non-invasive Glucose Monitoring Based on Optical Coherent Tomography
    Chen, Tseng-Lin
    Lo, Yu-Lung
    Quoc-Hung Phan
    BIOMEDICAL IMAGING AND SENSING CONFERENCE, 2018, 10711
  • [50] Design and Analysis of Non-Invasive Blood Glucose Levels Monitoring
    Sari, Marti Widya
    Luthfi, Muhtar
    2016 1ST INTERNATIONAL SEMINAR ON APPLICATION FOR TECHNOLOGY OF INFORMATION AND COMMUNICATION (ISEMANTIC): SCIENCE AND TECHNOLOGY FOR A BETTER FUTURE, 2016, : 134 - 137