Metal artifact reduction in CT-based attenuation correction of PET data using the virtual sinogram concept

被引:0
|
作者
Abdoli, Mehrsima [1 ]
Ay, Mohammad Reza [1 ]
Ahmadian, Alireza [1 ]
Zaidi, Habib [2 ]
机构
[1] Dept. Medical Physics and Biomedical Engineering, Research Institute for Nuclear Medicine, Tehran University of Medical Sciences, Tehran, Iran
[2] Division of Nuclear Medicine, Geneva University Hospital, Geneva, Switzerland
关键词
Compendex;
D O I
5163044
中图分类号
学科分类号
摘要
Metals
引用
收藏
相关论文
共 50 条
  • [21] Metal artifact reduction for CT-based luggage screening
    Karimi, Seemeen
    Martz, Harry
    Cosman, Pamela
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2015, 23 (04) : 435 - 451
  • [22] Evaluation of Surrogate Data Quality in Sinogram-Based CT Metal-Artifact Reduction
    Oehler, May
    Kratz, Baerbel
    Knopp, Tobias
    Mueller, Jan
    Buzug, Thorsten M.
    IMAGE RECONSTRUCTION FROM INCOMPLETE DATA V, 2008, 7076
  • [23] Clough-Tocher interpolation of virtual sinogram in a Delaunay triangulated grid for metal artifact reduction of PET/CT images
    Abdoli, M.
    de Long, J. R.
    Pruim, J.
    Dierckx, R. A. J. O.
    Zaidi, H.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3197 - 3201
  • [24] Automated CT-based Attenuation Correction for Preclinical Multimodality PET/CT
    Chen, Mu
    Osborne, Dustin
    Gleason, Shaun
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4043 - +
  • [25] Reduction of artefacts caused by hip implants in CT-based attenuation-corrected PET images using 2-D interpolation of a virtual sinogram on an irregular grid
    Mehrsima Abdoli
    Johan R. de Jong
    Jan Pruim
    Rudi A. J. O. Dierckx
    Habib Zaidi
    European Journal of Nuclear Medicine and Molecular Imaging, 2011, 38 : 2257 - 2268
  • [26] Accuracy of CT-based attenuation correction in PET/CT bone imaging
    Abella, Monica
    Alessio, Adam M.
    Mankoff, David A.
    MacDonald, Lawrence R.
    Jose Vaquero, Juan
    Desco, Manuel
    Kinahan, Paul E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (09):
  • [27] Accuracy of CT-Based attenuation correction in bone Imaging with PET/CT
    Abella, M.
    Mankof, D.
    Vaquero, J. J.
    Desco, M.
    Kinahan, P. E.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4485 - +
  • [28] Reduction of artefacts caused by hip implants in CT-based attenuation-corrected PET images using 2-D interpolation of a virtual sinogram on an irregular grid
    Abdoli, Mehrsima
    de Jong, Johan R.
    Pruim, Jan
    Dierckx, Rudi A. J. O.
    Zaidi, Habib
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (12) : 2257 - 2268
  • [29] Effect of different Chemoembolization materials on CT-based PET attenuation correction in PET/CT
    Heusner, T. A.
    Fronz, U.
    Jentzen, W.
    Verhagen, R.
    Bockisch, A.
    Antoch, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S151 - S151
  • [30] Metal Artifact Reduction in CT images by Sinogram TV inpainting
    Duan, Xinhui
    Zhang, Li
    Xiao, Yongshun
    Cheng, Jianping
    Chen, Zhiqiang
    Xing, Yuxiang
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3450 - +