Effects of non-uniform inlet flow on the performance of a molten carbonate fuel cell stack

被引:0
|
作者
Department of Mechanical Engineering, National Chiao Tung University, Hsinchu 30010, Taiwan [1 ]
机构
来源
J Chin Soc Mech Eng Trans Chin Inst Eng Ser C | 2007年 / 3卷 / 265-274期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
This study develops a quasi-three dimensional numerical method for analyzing three-dimensional temperature and cell voltage distribution in a ten-layer molten carbonate fuel cell. The authors consider the non-uniform profile as progressively increasing along the stacking direction, and assign it to the anode gas inlet or cathode gas inlet to form four kinds of patterns. Results indicate that the non-uniform molar flow rate of cathode gas obviously changes the temperature field of a molten carbonate fuel cell stack, and highest cell temperature occurs at the cathode gas exit in the layer with the lowest molar flow rate. Moreover, non-uniform anode gas in the stacking direction strongly affects cell voltage distribution in the molten carbonate fuel cell stack. Variation rate of average cell temperature and cell voltage among different layers along the stacking direction are 2% and 40%, apparently larger than the variation rate due to non-uniformity in the transverse direction in our previous research.
引用
收藏
相关论文
共 50 条
  • [41] Fabrication and operational experiences of a 6 kW molten carbonate fuel cell stack
    Seong-Ahn Hong
    Tae-Hoon Lim
    Suk-Woo Nam
    In-Hwan Oh
    Hee Chun Lim
    Korean Journal of Chemical Engineering, 2000, 17 : 193 - 197
  • [42] Pressure losses at dividing and combining junctions in a molten carbonate fuel cell stack
    Hirata, H
    Nakagaki, T
    Hori, M
    JOURNAL OF POWER SOURCES, 2001, 102 (1-2) : 118 - 123
  • [43] Hybrid Dynamic Modeling and Control of Molten Carbonate Fuel Cell Stack Shutdown
    李勇
    曹广益
    朱新坚
    Journal of Donghua University, 2007, (01) : 35 - 38
  • [44] Numerical studies of a separator for stack temperature control in a molten carbonate fuel cell
    Kim, Do Hyung
    Kim, Beom Joo
    Lim, Hee Chun
    Lee, Choong Gon
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2011, 36 (14) : 8499 - 8507
  • [45] Hybrid dynamic modeling and control of molten carbonate fuel cell stack shutdown
    Li, Yong
    Cao, Guang-Yi
    Zhu, Xin-Jian
    Journal of Donghua University (English Edition), 2007, 24 (01) : 35 - 38
  • [46] Effect of sulfur on the cell performance in a molten carbonate fuel cell
    Lee, Ki-Jeong
    Koomson, Samuel
    Lee, Choong-Gon
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2019, 36 (04) : 600 - 604
  • [47] Effect of sulfur on the cell performance in a molten carbonate fuel cell
    Ki-Jeong Lee
    Samuel Koomson
    Choong-Gon Lee
    Korean Journal of Chemical Engineering, 2019, 36 : 600 - 604
  • [49] Numerical analysis of molten carbonate fuel cell stack performance: diagnosis of internal conditions using cell voltage profiles
    Yoshiba, F
    Abe, T
    Watanabe, T
    JOURNAL OF POWER SOURCES, 2000, 87 (1-2) : 21 - 27
  • [50] Effect of non-uniform inlet flow rate on the heat-up process of a solid oxide fuel cell unit with cross-flow configuration
    Yuan, Ping
    Liu, Syu-Fang
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2016, 41 (28) : 12377 - 12386