Experimental study of a novel design bi-fluid based photovoltaic thermal (PVT)-assisted heat pump dryer

被引:2
|
作者
Aktekeli, Burak [1 ,2 ]
Aktas, Mustafa [3 ]
Kosan, Meltem [4 ]
Arslan, Erhan [5 ]
Sevik, Seyfi [6 ]
机构
[1] Gazi Univ, Nat & Appl Sci Inst, TR-06500 Ankara, Turkiye
[2] Bilecik Seyh Edebali Univ, Osmaneli Vocat Sch, Worker Hlth & Safety, TR-11500 Osmaneli, Turkiye
[3] Gazi Univ, Energy Syst Engn Dept, TR-06500 Ankara, Turkiye
[4] Kahramanmaras Istiklal Univ, Energy Syst Engn, Kahramanmaras, Turkiye
[5] TUBITAK Marmara Res Ctr, Gebze, Kocaeli, Turkiye
[6] Hitit Univ, Vocat Sch Tech Sci, Elect & Energy, Corum, Turkiye
关键词
Bi-fluid PVT; Direct-type heat pump; Compressed waste aluminum; Compact solar dryer; Mint drying process; INFRARED-CONVECTIVE DRYER; PHASE-CHANGE MATERIALS; PERFORMANCE ANALYSIS; SOLAR-ENERGY; SYSTEM; SIMULATION; EXERGY; MINT; IMPROVEMENT; ENHANCEMENT;
D O I
10.1016/j.renene.2024.121971
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study evaluated the performance of a novel design bi-fluid (air and refrigerant)-based photovoltaic thermal assisted heat pump dryer (BfPVTA-HPD), combining a compact bi-fluid PVT using curved directional fins that direct air at different points to the evaporator/waste aluminum material and HP system with a PVT air outlet mounted micro-channel condenser. BfPVTA-HPD was analyzed regarding energy, exergy, and drying characteristics at two different times, in clear and partially cloudy weather conditions. Mint leaves (Mentha piperita L.) were dried to evaluate BfPVTA-HPD's drying capabilities. The average electrical, thermal, and exergy efficiencies of PV and PVT for Exp-1 and Exp-2 varied to 15.97, 16.54%, 18.21, 18.23%, 55.36%, 42.04%, 30.95%, and 25.08 %, respectively. In Exp-1 and Exp-2, respectively, while an increase of 12.32 % and 9.29% in the average electrical efficiency was achieved by using PVT, an average of 3.15 and 2.86 were reached in the coefficient of performance (COP) of the heat pump. The exergy indicators (the improvement potential, sustainable index, and waste exergy ratio) for the Exp-1 are 839.52, 1.39, and 0.82. The exergy indicators for the Exp-2 are 1166.14, 1.30, and 0.84, respectively. The experiment's average mass transfer coefficients were obtained as 1.17 x 10- 8 and 7.75 x 10-9 m/s respectively. The experiment's average effective diffusivity coefficients were obtained as 2.90 x 10-11 and 2.04 x 10- 11 m2/s, respectively. The recommended BfPVTA-HPD can be used as a new model to improve the ecological footprint and green manufacturing. Furthermore, the electricity and heat production required for the sustainability of the drying system in spring and winter can be realized.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] Effect of glass cover and working fluid on the performance of photovoltaic thermal (PVT) system: An experimental study
    Kazemian, Arash
    Hosseinzadeh, Mohammad
    Sardarabadi, Mohammad
    Passandideh-Fard, Mohammad
    SOLAR ENERGY, 2018, 173 : 1002 - 1010
  • [22] Drying Kinetics and Quality Characteristics of Saffron Dried with a Heat Pump Assisted Hybrid Photovoltaic-thermal Solar Dryer
    Mortezapour, H.
    Ghobadian, B.
    Khoshtaghaza, M. H.
    Minaei, S.
    JOURNAL OF AGRICULTURAL SCIENCE AND TECHNOLOGY, 2014, 16 (01): : 33 - 45
  • [23] Investigating the annual performance of air-based collectors and novel bi-fluid based PV-thermal system
    Ul-Abdin, Zain
    Zeman, Miro
    Isabella, Olindo
    Santbergen, Rudi
    SOLAR ENERGY, 2024, 276
  • [24] Design and performance monitoring of a novel photovoltaic-thermal solar-assisted heat pump system for residential applications
    Leonforte, Fabrizio
    Miglioli, Alessandro
    Aste, Niccolo
    Cristiani, Nicolo
    Croci, Lorenzo
    Besagni, Giorgio
    Del Pero, Claudio
    APPLIED THERMAL ENGINEERING, 2022, 210
  • [25] Experimental study of a novel photovoltaic-thermal-thermoelectric generator-based solar dryer for grapes drying
    Singh, Ajay Pratap
    Gupta, Ankur
    Biswas, Agnimitra
    Das, Biplab
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2024, 21 (05) : 1161 - 1173
  • [26] Design, fabrication and experimental study of a solar photovoltaic/loop-heat-pipe based heat pump system
    Zhang, Xingxing
    Zhao, Xudong
    Shen, Jingchun
    Hu, Xi
    Liu, Xuezhi
    Xu, Jihuan
    SOLAR ENERGY, 2013, 97 : 551 - 568
  • [27] A study of photovoltaic/thermal (PVT)-ground source heat pump hybrid system by using fuzzy logic control
    Putrayudha, S. Andrew
    Kang, Eun Chul
    Evgueniy, E.
    Libing, Y.
    Lee, Euy Joon
    APPLIED THERMAL ENGINEERING, 2015, 89 : 578 - 586
  • [29] Experimental study on a novel microwave-assisted adsorption heat pump
    Demir, H. (hasandemir@osmaniye.edu.tr), 1600, Elsevier Ltd (45):
  • [30] Experimental study of a photovoltaic solar-assisted heat pump/gravity-assisted heat pipe hybrid system
    Zhang, T.
    Zhang, Y. F.
    Shi, Z. R.
    Li, Q. F.
    Cai, J. Y.
    RENEWABLE ENERGY, 2023, 207 : 147 - 161