Impact of fault clearing time on shaft torque amplification in multi-mode sub-synchronous resonance

被引:0
|
作者
机构
[1] Weng, Zong-Lin
[2] Lu, Ji-Ping
[3] Qiao, Liang
[4] Gao, Dao-Chun
[5] Xie, Ying-Zhao
[6] Xu, Bing
[7] Yin, Yuan
来源
Weng, Z.-L. (wengzonglin712@126.com) | 1600年 / Power System Protection and Control Press卷 / 40期
关键词
Modal analysis;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 21 条
  • [1] Mechanism and mitigation of multi-mode sub-synchronous resonance
    Department of Electrical Engineering, Tsinghua University, Beijing 100084, China
    Qinghua Daxue Xuebao, 2008, 4 (457-460): : 457 - 460
  • [2] Impact of fault clearing time on shaft torque amplification in series compensated system
    Luo, Yuhang
    Bi, Tianshu
    Zhang, Tao
    Yang, Qixun
    2008 THIRD INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1-6, 2008, : 709 - 713
  • [3] Eigenvalue analysis of multi-mode sub-synchronous resonance for multimachine plant-to-grid transmission systems with fixed series compensation
    State Key Lab of Control and Simulation of Power Systems and Generation Equipments, Dept. of Electrical Engineering, Tsinghua University, Haidian District, Beijing 100084, China
    Zhongguo Dianji Gongcheng Xuebao, 2008, SUPPL. (13-18):
  • [4] Time-frequency distribution application for sub-synchronous resonance analysis in power systems
    Yousif, Nadia
    Al-Dabbagh, Majid
    IPEC: 2005 International Power Engineering Conference, Vols 1 and 2, 2005, : 771 - 775
  • [5] Shaft torsion simulation of sub-synchronous resonance (SSR) for large-scale turbo-generator setpart
    Xiao, You-Qiang
    Yang, Shun-Chang
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2001, 21 (SUPPL.): : 16 - 19
  • [6] Analysis of sub-synchronous resonance between DC-side dynamics of large-scale PV plants and nearby synchronous generators shaft
    Pourheydari, Mohammad
    Parniani, Mostafa
    Ravanji, Mohammad Hasan
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2023, 17 (09) : 1999 - 2014
  • [7] Research on impact on sub-synchronous resonance risk from DFIG number and grid structure in Guyuan area
    Yin M.
    Liu H.
    Li Y.
    Song W.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2021, 42 (01): : 174 - 179
  • [8] A minimum-time based fuzzy logic dynamic braking resistor control for sub-synchronous resonance
    Rahim, AHMA
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2004, 26 (03) : 191 - 198
  • [9] Design and optimization analysis of ultrasonic lysis system based on multi-mode synchronous resonance
    Qiao, Longxue
    Du, Yaohua
    Chen, Feng
    Wu, Jinlong
    Wu, Taihu
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2016, 37 (01): : 48 - 56
  • [10] Application of Gate-Controlled Series Capacitors (GCSC) for Reducing Stresses due to Sub-Synchronous Resonance in Turbine-Generator Shaft
    Umre, B. S.
    Helonde, J. B.
    Modak, J. P.
    Renkey , Sonali
    2010 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, 2010, : 2300 - 2305