Mechanical and chemical stability of injection-molded microcantilevers used for sensing

被引:0
|
作者
机构
[1] [1,Urwyler, Prabitha
[2] Pascual, Alfons
[3] 3,Kristiansen, Per Magnus
[4] 1,Gobrecht, Jens
[5] Müller, Bert
[6] 1,Schift, Helmut
来源
Schift, H. (helmut.schift@psi.ch) | 1600年 / John Wiley and Sons Inc卷 / 127期
关键词
Ultraviolet-ozone treatment is used as a standard surface cleaning procedure for removal of molecular organic contamination from analytical and sensing devices. Here; it is applied for injection-molded polymer microcantilevers before characterization and sensing experiments. This article examines the effects of the surface cleaning process using commercial equipment; in particular on the performance and mechanical properties of the cantilevers. It can be shown that the first chemical aging process essentially consist of the cross linking of the polymer chains together with a physical aging of the material. For longer exposure; the expected thermo-oxidative formation of carbonyl groups sets in and an exposure dependent chemical degradation can be detected. A process time of 20 min was found suitable as a trade-off between cleaning and stability. © 2012 Wiley Periodicals; Inc; J; Appl; Polym; Sci; 2013 Copyright © 2012 Wiley Periodicals;
D O I
暂无
中图分类号
学科分类号
摘要
Journal article (JA)
引用
收藏
相关论文
共 50 条
  • [31] Mechanical properties of injection-molded isotactic polypropylene/roselle fiber composites
    Junkasem, Jirawut
    Menges, James
    Supaphol, Pitt
    JOURNAL OF APPLIED POLYMER SCIENCE, 2006, 101 (05) : 3291 - 3300
  • [32] ON THE INFLUENCE OF PROCESSING TEMPERATURE ON THE MECHANICAL-BEHAVIOR OF INJECTION-MOLDED PARTS
    CRIENS, RM
    MOSLE, HG
    PLASTICS ENGINEERING, 1984, 40 (03) : 60 - 60
  • [33] Physical and mechanical properties of injection-molded wood powder thermoplastic composites
    Yu, Ying
    Yang, Yuqiu
    Murakami, Masuo
    Nomura, Manabu
    Hamada, Hiroyuki
    ADVANCED COMPOSITE MATERIALS, 2013, 22 (06) : 425 - 435
  • [34] MECHANICAL ANISOTROPY AND ORIENTATION OF INJECTION-MOLDED POLY(ETHYLENE-TEREPHTHALATE)
    RUEDA, DR
    KUBERA, L
    BALTACALLEJA, FJ
    BAYER, RK
    JOURNAL OF MATERIALS SCIENCE LETTERS, 1993, 12 (14) : 1140 - 1143
  • [35] Mechanical Behavior-Microstructure Relationships in Injection-Molded Polyamide 66
    Billon, Noelle
    Giraudeau, Joan
    Bouvard, Jean Luc
    Robert, Gilles
    POLYMERS, 2018, 10 (10)
  • [36] Mechanical properties of injection-molded composites of carbon nanofibers in polypropylene matrix
    Enomoto, K
    Yasuhara, T
    Ohtake, N
    NEW DIAMOND AND FRONTIER CARBON TECHNOLOGY, 2005, 15 (02): : 59 - 72
  • [37] EFFECTS OF MOLD TEMPERATURE ON MECHANICAL PROPERTIES OF AN INJECTION-MOLDED PART WITH MICROFEATURES
    Park, Keun
    Kim, Young-Seog
    JOURNAL OF POLYMER ENGINEERING, 2009, 29 (1-3) : 135 - 153
  • [38] Mechanical characterization of injection-molded macro porous bioceramic bone scaffolds
    Vivanco, Juan
    Aiyangar, Ameet
    Araneda, Aldo
    Ploeg, Heidi-Lynn
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2012, 9 : 137 - 152
  • [39] Mechanical Properties of Injection-Molded Glass Microsphere-Reinforced Polyamide
    Capela, C.
    Ferreira, J. M.
    Costa, J. M.
    Mendes, N.
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2016, 25 (10) : 4256 - 4265
  • [40] Mechanical Properties of Injection-Molded Glass Microsphere-Reinforced Polyamide
    C. Capela
    J. M. Ferreira
    J. M. Costa
    N. Mendes
    Journal of Materials Engineering and Performance, 2016, 25 : 4256 - 4265