High sensitivity PEA system with dual polarity pulse generator

被引:1
|
作者
Musashi Institute of Technology, Japan [1 ]
不详 [2 ]
不详 [3 ]
不详 [4 ]
机构
来源
IEEJ Trans. Fundam. Mater. | 2006年 / 3卷 / 178-184+12期
关键词
Electric field effects - Electric potential - Electric space charge - Sensitivity analysis - Stress analysis;
D O I
10.1541/ieejfms.126.178
中图分类号
学科分类号
摘要
The pulsed electroacoustic (PEA) method has been widely used to observe space charge distributions in various solid dielectric materials. The sensitivity of the conventional PEA system is around 1 C/m3. When the charge density is less than 1 C/m3, however, it is difficult to obtain an accurate result because the signal due to the Maxwell stress becomes comparable with the signal to be measured. The Maxwell stress is generated by applying the pulsed electric field to the dielectrics, and independent from the existence of either induced charges by dc bias voltage or internal charges. In order to eliminate the influence of the Maxwell stress, we have developed a new PEA system with a dual polarity pulse generator. The system achieved to measure space charge density around 0.03 C/m3.
引用
收藏
相关论文
共 50 条
  • [21] Multifunctional pulse generator for high-intensity focused ultrasound system
    Tamano, Satoshi
    Yoshizawa, Shin
    Umemura, Shin-Ichiro
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2017, 56 (07)
  • [22] A Novel Bipolar Pulse Generator for High-frequency Ultrasound System
    Wu, Jian-Xing
    Du, Yi-Chun
    Lin, Chia-Hung
    Chen, Pei-Jarn
    Chen, Tainsong
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 1567 - 1570
  • [23] The Research of ns-class Ultra Narrow High-Voltage Pulse Generator Applied for PEA Method
    Xiang, Peizhong
    Xiang, Xuyang
    2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,
  • [24] DESIGN CONSIDERATIONS FOR A DUAL CHAMBER DUAL SENSOR PULSE-GENERATOR
    ADLER, SC
    LEE, MT
    CALFEE, RV
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (05): : 1205 - 1205
  • [25] A Very High Sensitivity RF Pulse Profile Measurement System
    Lai, Jesse B.
    Christodoulou, Christos G.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2010, 59 (06) : 1616 - 1623
  • [26] DUAL CHAMBER RATE RESPONSIVE PULSE-GENERATOR
    HERPERS, L
    DEROOS, C
    WEIJAND, K
    BOURGEOIS, I
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (03): : 687 - 687
  • [27] Multiple pulse generator malfunctions with a dual chamber pacemaker
    Lipchenca, I
    Barlev, D
    Luria, D
    Granit, C
    Rotshtein, Z
    Eldar, M
    Glikson, M
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (06): : 936 - 939
  • [28] FAST HIGH CURRENT PULSE GENERATOR
    PEARCE, TW
    HOCHBERG, AK
    POEHLER, TO
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1967, 38 (06): : 835 - &
  • [29] HIGH-CURRENT PULSE GENERATOR
    DICKEY, FE
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1962, 109 (03) : C85 - C85
  • [30] HIGH-VOLTAGE PULSE GENERATOR
    BARABASH, LZ
    KRYZHANOVSKII, OI
    LEBEDEV, PI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1970, (01): : 133 - +