A TDLAS gas detection method based on digital signal modulation

被引:0
|
作者
Zhang, Lei [1 ]
Dai, Xin [1 ]
Zhang, Weihua [1 ]
Wang, Wenqing [1 ]
Liu, Xiaochen [1 ]
Li, Wenbo [1 ]
机构
[1] Shenyang Fire Sci & Technol Res Inst MEM, 218A Wenda Rd, Shenyang, Liaoning, Peoples R China
关键词
Optical sensing and sensors; Tunable diode laser absorption spectroscopy; Wavelength modulation spectroscopy; Direct absorption spectroscopy; Digital signal processing methods; SPECTROSCOPY; SENSOR; N2O;
D O I
10.1016/j.optcom.2024.131211
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
This research presents a novel TDLAS gas concentration detection method based on digital modulation. The method inherits the advantage of a simple system structure from Direct Absorption Spectroscopy, as well as the excellent sensitivity of Wavelength Modulation Spectroscopy. A low-frequency sawtooth wave is employed to drive the laser, resulting in a digital direct absorption spectrum signal. By constructing a cosine modulation sequence in the time domain and performing linear interpolation on the direct absorption spectrum, it successfully converts to a wavelength-modulated absorption spectrum and simultaneously generates a digital reference signal at double the frequency. Ultimately, phase-locked amplification technology can be used to calculate the amplitude of the second harmonic. Since both the modulation and reference signals are generated digitally, they ensure a strict frequency-doubling relationship and phase correlation, which not only reduces the complexity of the hardware system but also effectively minimizes system errors. Because digital technology generates both the modulation and reference signals, it ensures that they have the same phase and a strict frequency-doubling relationship. Experimental results demonstrate that, when fitted by a cubic polynomial, the second harmonic amplitude and the gas concentration have a correlation coefficient (R2) 2 ) as high as 0.99999 and a root mean square error as low as 0.0011. This proves the method's great accuracy and reliability in practical applications.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Signal Processing Method of Correlation Detection for Ranging System Based on Combined Modulation
    Hao, Xinhong
    Bai, Yupeng
    Cui, Zhanzhong
    2008 7TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION, VOLS 1-23, 2008, : 1373 - 1377
  • [22] Simulation and Influencing Factors Analysis of Gas Detection System Based on TDLAS Technology
    Wang Guo-shui
    Guo Ao
    Liu Xiao-nan
    Feng Lei
    Chang Peng-hao
    Zhang Li-ming
    Liu Long
    Yang Xiao-tao
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41 (10) : 3262 - 3268
  • [23] Application of TDM and FDM methods in TDLAS based multi-gas detection
    Feng, Yiwen
    Chang, Jun
    Chen, Xiaohan
    Zhang, Qinduan
    Wang, Zongliang
    Sun, Jiachen
    Zhang, Zhiwen
    OPTICAL AND QUANTUM ELECTRONICS, 2021, 53 (04)
  • [24] Wavelength modulation spectroscopy with signal-reference beam method for highly sensitive gas detection
    Wei, Wei
    Chang, Jun
    Huang, Qingjie
    Zhu, Cunguang
    Wang, Qiang
    Wang, Zongliang
    Lv, Guangping
    APPLIED PHYSICS B-LASERS AND OPTICS, 2015, 118 (01): : 75 - 83
  • [25] An Investigation of Temperature Compensation of HCL Gas Online Monitoring Based on TDLAS Method
    Shu Xiao-wen
    Zhang Yu-jun
    Kan Rui-feng
    Cu Yi-ben
    He Ying
    Zhang Shuai
    Geng Hui
    Liu Wen-qing
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30 (05) : 1352 - 1356
  • [26] Research on gas concentration field reconstruction method based on laser SLAM and TDLAS
    Cui, Pengxiang
    Chen, Jiuying
    Zhou, Chuncheng
    Yu, Xiaoya
    Zhang, Huijing
    Wang, Ping
    Wang, Ning
    Ma, Lingling
    INFRARED PHYSICS & TECHNOLOGY, 2025, 145
  • [27] A flue gas velocimeter based on the hyperbolic chirp modulation method of acoustic source signal
    Zhao, Xuhao
    Liu, Qi
    Zhou, Bin
    Dai, Minglu
    Zhao, Rong
    Gao, Ben
    Jian, Yanchen
    SENSORS AND ACTUATORS A-PHYSICAL, 2024, 373
  • [28] An Indirect Measurement Method for Gas Consumption of a Diaphragm Gas Meter Based on Gas Pressure Signal Detection
    Han, Zhao
    Wang, Xiaoli
    Jiang, Baochen
    Chen, Xiaopeng
    APPLIED SCIENCES-BASEL, 2019, 9 (12):
  • [29] A low computation detection method of signal nonlinear distortion based on digital quadrature detection principle
    Peng-Cheng Wang
    Xiao-Ping Huang
    EURASIP Journal on Advances in Signal Processing, 2023
  • [30] A low computation detection method of signal nonlinear distortion based on digital quadrature detection principle
    Wang, Peng-Cheng
    Huang, Xiao-Ping
    EURASIP JOURNAL ON ADVANCES IN SIGNAL PROCESSING, 2023, 2023 (01)