Analysis of partial discharge test of UHV transformer

被引:0
|
作者
Wu, Zhi-Rong [1 ]
Nie, De-Xin [1 ]
Chen, Jiang-Bo [1 ]
机构
[1] State Grid Electric Power Research Institute, Wuhan 430074, China
来源
关键词
Electric transformer testing - Bushings - Power transformers;
D O I
暂无
中图分类号
学科分类号
摘要
1000 kV Jindongnan-Nanyang-Jingmen ultra-high voltage (UHV) AC Pilot Project is the highest power transmission voltage level in China. It is also the first time to carry out partial discharge test with 1000 kV and 1000 MVA UHV AC power transformer in China. The test is very difficult due to the high voltage and strict demand in partial discharge level. In this paper, the ODFPS-1000000/1000 UHV transformer made by TBEA, which is locating at Jingmen substation, is taken for an example to analyze its pre-delivery partial discharge test. Partial discharge test types for bushing 1000 kV Jindongnan-Nanyang-Jingmen UHV AC Pilot Project Electrical Apparatus Hand-over Test Standard from State Grid Corporation of China and hand-over test. The characteristics of UHV transformer partial discharge are summarized and special requests for UHV transformer test are put forward.
引用
收藏
页码:54 / 61
相关论文
共 50 条
  • [31] On-site Transformer Partial Discharge Diagnosis
    Gross, Detlev W.
    Soeller, Markus
    CONFERENCE RECORD OF THE 2012 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION (ISEI), 2012, : 558 - 564
  • [32] Practical location method of transformer partial discharge
    Li, YQ
    Lu, FC
    Xie, HL
    Yin, M
    2004 International Conference on Power System Technology - POWERCON, Vols 1 and 2, 2004, : 1371 - 1374
  • [33] STUDY ON PARTIAL DISCHARGE SIGNAL DENOISING OF TRANSFORMER
    Zheng, Yanyan
    Zhu, Yongli
    FRESENIUS ENVIRONMENTAL BULLETIN, 2020, 29 (4A): : 2707 - 2710
  • [34] RF detection of partial discharge in current transformer
    Chen, Mu-Kuen
    Chang, Wen-Yeau
    Chen, Jeng-Ming
    Cheng, Chao-Yuan
    2007 CONFERENCE PROCEEDINGS IPEC, VOLS 1-3, 2007, : 193 - 196
  • [35] Summary of transformer partial discharge detection methods
    Li Yanda
    PROCEEDINGS OF THE FIRST INTERNATIONAL CONFERENCE ON INFORMATION SCIENCES, MACHINERY, MATERIALS AND ENERGY (ICISMME 2015), 2015, 126 : 1802 - 1805
  • [36] Estimating Transformer Parameters for Partial Discharge Location
    Hettiwatte, Sujeewa N.
    Wang, Zhongdong
    Crossley, Peter A.
    2014 AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC), 2014,
  • [37] Identification of partial discharge defects in transformer oil
    Jongen, RA
    Morshuis, P
    Meijer, S
    Smit, JJ
    2005 Annual Report Conference on Electrical Insulation and Dielectric Phenomena, 2005, : 565 - 568
  • [38] The orientation estimation of partial discharge in power transformer
    Xie Hongling
    Li Yanqing
    Wu Jianfeng
    Mao Weiming
    Li Yun
    2008 THIRD INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1-6, 2008, : 995 - 998
  • [39] The study of propagation characteristics of partial discharge in transformer
    Qin, SZ
    Birlasekaran, S
    2002 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2002, : 446 - 449
  • [40] Dynamic Stability Analysis of UHV Converter Transformer Winding
    Li J.
    Zhang S.
    Cheng H.
    Zhang J.
    Zhao X.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2023, 43 (08): : 3237 - 3247