Determination of phosphorus by molecular absorption of phosphorus monoxide using a high-resolution continuum source absorption spectrometer and an air-acetylene flame

被引:0
|
作者
Huang, M.D. [1 ]
Becker-Ross, H. [1 ]
Florek, S. [1 ]
Heitmann, U. [1 ]
Okruss, M. [2 ]
机构
[1] ISAS - Institute for Analytical Sciences, Department Berlin, Albert-Einstein-Str. 9, 12489 Berlin, Germany
[2] Gesellschaft zur Förderung Angewandter Optik, Optoelektronik, Quantenelektronik und Spektroskopie (GOS) e.V., Rudower Chaussee 29, 12489 Berlin, Germany
来源
关键词
PO molecular absorption bands; produced between 200 nm and 350 nm in an ordinary air-acetylene flame; were investigated using a high-resolution continuum source absorption spectrometer. The bands comprise sharp structures with half-widths similar to those of common atomic lines. Four PO band heads; located at 246.40 nm; 247.78; nm; 324.62 nm and 327.04 nm; were selected and systematically evaluated with regard to the determination of phosphorus. Nitric; sulfuric; hydrochloric and hydrofluoric acids; with concentrations of up to 5% (v/v); and up to 2000 mg L-1solutions of Al; Co; Cr; Cu; Fe; K; Mn; Na; and Ni; were examined for possible matrix or spectral interferences. The only serious spectral interference found was the disturbance of the PO band head at 324.62 nm by the 324.754 nm Cu resonance line at high concentrations. Apart from this; a suppression effect on the PO absorption caused by the presence of Ca and Mg was observed and will be discussed in a separate paper in this journal. The determination of phosphorus via molecular PO absorption proved to be a rapid and reliable method. Performance was verified by analyses of standard reference materials; where good precision and accuracy were achieved. The limit of detection for phosphorus was found to be 1.3 mg L-1for a measurement time of 25 s; using the PO band head at 324.62 nm. The linear dynamic range covers more than three orders of magnitude. © the Royal Society of Chemistry 2006;
D O I
暂无
中图分类号
学科分类号
摘要
Journal article (JA)
引用
收藏
页码:338 / 345
相关论文
共 50 条
  • [21] ATOMIC AND MOLECULAR ABSORPTION-SPECTRA OF INDIUM IN AIR-ACETYLENE FLAME
    HARAGUCHI, H
    FUWA, K
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1975, 30 (12) : 535 - 545
  • [22] Evaluation of Lines of Phosphorus and Potassium by High-Resolution Continuum Source Flame Atomic Absorption Spectrometry for Liquid Fertilizer Analysis
    Ferreira, Roberta Borges
    Oliveira, Silvana Ruella
    Franzini, Vanessa Pezza
    Virgilio, Alex
    Raposo Junior, Jorge Luiz
    Gomes Neto, Jose Anchieta
    ATOMIC SPECTROSCOPY, 2011, 32 (02) : 56 - 61
  • [23] Evaluation of lines of boron, phosphorus and sulfur by high-resolution continuum source flame atomic absorption spectrometry for plant analysis
    Bechlin, Marcos Andre
    Gomes Neto, Jose Anchieta
    Nobrega, Joaquim Araujo
    MICROCHEMICAL JOURNAL, 2013, 109 : 134 - 138
  • [24] INDIRECT ATOMIC-ABSORPTION SPECTROMETRIC DETERMINATION OF ALKALOIDS USING AN AIR-ACETYLENE FLAME
    KIR, S
    TEMIZER, A
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (07) : 657 - 659
  • [25] Determination of sulfur in food by high resolution continuum source flame molecular absorption spectrometry
    Zambrzycka, Elzbieta
    Godlewska-Zylkiewicz, Beata
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2014, 101 : 234 - 239
  • [26] Method development for the determination of fluorine in toothpaste via molecular absorption of aluminum mono fluoride using a high-resolution continuum source nitrous oxide/acetylene flame atomic absorption spectrophotometer
    Ozbek, Nil
    Akman, Suleyman
    TALANTA, 2012, 94 : 246 - 250
  • [27] Feasibility of high-resolution continuum source molecular absorption spectrometry for vanadium determination
    Kowalewska, Zofia
    Abad, Carlos
    Okruss, Michael
    Recknagel, Sebastian
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (02) : 472 - 483
  • [28] PHOTODISSOCIATION OF SODIUM HALIDES IN AIR-ACETYLENE FLAME AS STUDIED BY MOLECULAR ABSORPTION FLAME SPECTROSCOPY
    FURUTA, N
    YOSHIMURA, E
    NEMOTO, Y
    HARAGUCHI, H
    FUWA, K
    CHEMISTRY LETTERS, 1976, (06) : 539 - 542
  • [29] Determination of phosphorus using high-resolution diphosphorus molecular absorption spectra produced in the graphite furnace
    Huang, Mao Dong
    Becker-Ross, Helmut
    Okruss, Michael
    Geisler, Sebastian
    Florek, Stefan
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2016, 115 : 23 - 30
  • [30] Determination of bromine using high-resolution continuum source molecular absorption spectrometry in a graphite furnace
    Limburg, Tobias
    Einax, Jurgen W.
    MICROCHEMICAL JOURNAL, 2013, 107 : 31 - 36