Flashover performance of 500 kV ice-covered porcelain post insulators with composite assistant shed

被引:3
|
作者
Xu, Tao [1 ,2 ]
Wang, Hai-Ming [3 ]
Wang, Lin-Lin [4 ]
Xu, Zuo-Ming [2 ]
Yao, Tao [2 ]
Cai, Lin [2 ]
机构
[1] School of Electrical Engineering, Wuhan University, Wuhan 430072, China
[2] State Grid Electric Power Research Institute, Wuhan 430074, China
[3] Xinxiang Power Company, Xinxiang 453002, China
[4] Henan Transmission and Distribution Construction Company, Zhengzhou 450051, China
来源
关键词
Insulator contamination - Leakage currents;
D O I
10.3969/j.issn.1003-6520.2012.01.023
中图分类号
O441.1 [电学]; TM12 [];
学科分类号
摘要
引用
收藏
页码:167 / 172
相关论文
共 50 条
  • [31] Calculation of Critical Flashover Voltage of Ice-Covered Insulators Using the Finite Element Method
    Volat, C.
    Farzaneh, M.
    Mhaguen, N.
    CEIDP: 2009 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2009, : 403 - 406
  • [32] Equivalence of Influence of Pollution Simulating Methods on DC Flashover Stress of Ice-Covered Insulators
    Jiang, Xingliang
    Chen, Ling
    Zhang, Zhijin
    Sun, Caixin
    Hu, Jianlin
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (04) : 2113 - 2120
  • [33] Flashover Characteristics of 110 kV Snow-covered Post Insulators
    Mei H.
    Shi Q.
    Lu M.
    Wang L.
    Liu Z.
    Zhang C.
    Gaodianya Jishu/High Voltage Engineering, 2018, 44 (12): : 3944 - 3950
  • [34] Switching impulse flashover performance of 110 kV composite insulator covered-with ice
    Jiang, Xing-Liang
    Sheng, Dao-Wei
    Yuan, Ji-He
    Gaodianya Jishu/High Voltage Engineering, 2009, 35 (04): : 772 - 776
  • [35] Modeling of DC flashover on ice-covered HV insulators based on dynamic electric field analysis
    Yang, Qing
    Sima, Wenxia
    Sun, Caixin
    Shu, Lichun
    Hu, Qin
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2007, 14 (06) : 1418 - 1426
  • [36] AC flashover characteristics and arc development process of glaze ice-covered insulators in natural environment
    Zong, Chunyu
    Hu, Yuyao
    Jiang, Xingliang
    Xian, Richang
    Liu, Zongyuan
    Sun, Jianliang
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 135
  • [37] The Influence of Booster Sheds on AC Flashover Performance of Ice-covered 750 kV Class Tension Insulator Strings
    Hu, Jianlin
    Xu, Ke
    Jiang, Xingliang
    Wu, Yao
    Zhang, Zhijin
    Shun, Lichun
    Lan, Binhuan
    2014 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2014,
  • [38] Modelling of flashover performance of an ice-covered resistive glazed post station insulator in presence of an air gap
    Jaiswal, V
    Farzaneh, M
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2006, 39 (01) : 227 - 232
  • [39] Effects of icing degree on ice growth characteristics and flashover performance of 220 kV composite insulators
    Hu, Qin
    Wang, Shijing
    Yang, Hongjun
    Shu, Lichun
    Jiang, Xingliang
    Li, Hantao
    Qi, Jiahao
    Liu, Yanqing
    COLD REGIONS SCIENCE AND TECHNOLOGY, 2016, 128 : 47 - 56
  • [40] Comparison on ac icing flashover performance of porcelain, glass, and composite insulators
    Jiang, Xingliang
    Xiang, Ze
    Zhang, Zhijin
    Hu, Jianlin
    Hu, Qin
    Shu, Lichun
    Cold Regions Science and Technology, 2014, 100 : 1 - 7