Flashover performance of 500 kV ice-covered porcelain post insulators with composite assistant shed

被引:3
|
作者
Xu, Tao [1 ,2 ]
Wang, Hai-Ming [3 ]
Wang, Lin-Lin [4 ]
Xu, Zuo-Ming [2 ]
Yao, Tao [2 ]
Cai, Lin [2 ]
机构
[1] School of Electrical Engineering, Wuhan University, Wuhan 430072, China
[2] State Grid Electric Power Research Institute, Wuhan 430074, China
[3] Xinxiang Power Company, Xinxiang 453002, China
[4] Henan Transmission and Distribution Construction Company, Zhengzhou 450051, China
来源
关键词
Insulator contamination - Leakage currents;
D O I
10.3969/j.issn.1003-6520.2012.01.023
中图分类号
O441.1 [电学]; TM12 [];
学科分类号
摘要
引用
收藏
页码:167 / 172
相关论文
共 50 条
  • [1] Effect of Shed Configuration on DC Flashover Performance of Ice-covered 110 kV Composite Insulators
    Jiang, Xingliang
    Dong, Bingbing
    Zhang, Zhijin
    Yin, Fanghui
    Shu, Lichun
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (03) : 699 - 705
  • [2] Flashover performance of ice-covered insulators
    Farzaneh, M
    Kiernicki, J
    CANADIAN JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING-REVUE CANADIENNE DE GENIE ELECTRIQUE ET INFORMATIQUE, 1997, 22 (03): : 95 - 109
  • [3] Modeling of AC Flashover on Ice-covered Composite Insulators with Different Shed Configurations
    Shu, Lichun
    Wang, Shijing
    Jiang, Xingliang
    Hu, Qin
    Liang, Jian
    Yin, Pancheng
    Chen, Ji
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (06) : 2642 - 2651
  • [4] Effects of Shed Configuration on AC Flashover Performance of Ice-covered Composite Long-rod Insulators
    Hu, Qin
    Shu, Lichun
    Jiang, Xingliang
    Sun, Caixin
    Zhang, Zhijin
    Hu, Jianlin
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (01) : 200 - 208
  • [5] Influences of Grading Ring Arrangement on AC Flashover Performance of 220 kV Ice-covered Composite Insulators
    Shu, Lichun
    Wang, Shijing
    Jiang, Xingliang
    Hu, Qin
    He, Yanzhun
    Wu, Zhi
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (06) : 2652 - 2661
  • [6] DC Flashover Performance of Ice-Covered Composite Insulators with Parallel Air Gaps
    Hu, Jianlin
    Jiang, Xingliang
    Yin, Fanghui
    Zhang, Zhijin
    ENERGIES, 2015, 8 (06): : 4983 - 4999
  • [7] Study of DC Flashover Performance of Ice-covered Insulators at High Altitude
    Jiang, Xingliang
    Zhao, Shihua
    Hu, Jianlin
    Zhang, Zhijin
    Shu, Lichun
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (02) : 391 - 400
  • [8] Influence of Test Methods on DC Flashover Performance of Ice-covered Composite Insulators and Statistical Analysis
    Jiang, Xingliang
    Bi, Maoqiang
    Hu, Jianlin
    Zhang, Zhijing
    Xia, Yunfeng
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (06) : 2019 - 2028
  • [9] Application of dynamic model to flashover of ice-covered insulators
    Fofana, I.
    Farzaneh, M.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2007, 14 (06) : 1410 - 1417
  • [10] AC Flashover Characteristics of Ice-Covered Suspension Insulators
    Li, Zhou
    Wang, Qingliang
    Zhang, Jun
    Jia, Huidong
    Zhang, Qiaogen
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 3913 - 3916