Performance for hybrid refrigerants in function proving refrigeration cycle

被引:0
|
作者
Nie, Xueli [1 ]
Shi, Yang [1 ]
Gong, Yi [1 ]
Zhao, Xiangge [1 ]
Wang, Zhimin [2 ]
机构
[1] Department of Mechanical and Electrical Engineering, ZhengZhou University of Light industry, ZhengZhou 450002, China
[2] Zhengzhou Great Wall Scientific Industrial and Trade Co. Ltd, ZhengZhou 450002, China
来源
Energy Education Science and Technology Part A: Energy Science and Research | 2013年 / 31卷 / 01期
关键词
Auto-cascade refrigeration - Discharge pressures - Heat balance method - Lower temperatures - Performance - Refrigeration cycles - State of system - Suction pressures;
D O I
暂无
中图分类号
学科分类号
摘要
The performance of hybrid refrigerants in function proving refrigeration cycle was developed in this paper. Selection for constituent and calculation method was validated by the experiment in the cryogenic tank. and the experimental result of the hybrid refrigerants was to achieve lower temperature of below zero 100{top square bracket} for the cryogenic tank, When the state of system was steady, the suction pressure of the compressor was 0.28 MPa, the discharge pressure was 1.98 MPa. Flow rate of work substance was calculated with the series heat balance method after simplifying the cycle, the error was little and it was feasible. © Sila Science.
引用
收藏
页码:573 / 576
相关论文
共 50 条
  • [31] Performance of compression/absorption hybrid refrigeration cycle with propane/mineral oil combination
    Fukuta, M
    Yanagisawa, T
    Iwata, H
    Tada, K
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2002, 25 (07): : 907 - 915
  • [32] Thermodynamic performance of a hybrid air cycle refrigeration system using a desiccant rotor
    Kyudae Hwang
    Chan Ho Song
    Sung Ki Kim
    Kiyoshi Saito
    Sunao Kawai
    Heat and Mass Transfer, 2013, 49 : 359 - 367
  • [33] Influence of leakage of natural non-azeotropic mixture refrigerants on system performance in an auto-cascade refrigeration cycle
    Yan, J.
    Yan, G.
    Qian, W.
    Wang, W.
    CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 471 - 475
  • [34] Development and performance analysis of a multi-temperature combined compression/ejection refrigeration cycle using environment friendly refrigerants
    Lontsi, F.
    Hamandjoda, O.
    Mayi, O. T. Sosso
    Kemajou, A.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 69 : 42 - 50
  • [35] Theoretical performance studies on environment friendly refrigerants used in refrigeration units
    Nagarjuna Kumma
    Gokul Sai Seethala
    Yatna Bhagat
    Sai Sarath
    Satya Sai Harish Kruthiventi
    Environmental Science and Pollution Research, 2023, 30 : 63065 - 63083
  • [36] Theoretical performance studies on environment friendly refrigerants used in refrigeration units
    Kumma, Nagarjuna
    Seethala, Gokul Sai
    Bhagat, Yatna
    Sarath, Sai
    Kruthiventi, Satya Sai Harish
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2023, 30 (22) : 63065 - 63083
  • [37] Investigation on performance of ejector and optimal refrigerants for solar ejector refrigeration system
    Zhang, Yufeng
    Zhao, Wei
    Tian, Qi
    Sun, Yuexia
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2007, 28 (02): : 130 - 136
  • [38] Performance of Non-CFC Refrigerants for Low-Temperature Refrigeration
    Rajapaksha, Leelananda
    ENGINEER-JOURNAL OF THE INSTITUTION OF ENGINEERS SRI LANKA, 2009, 42 (02): : 25 - 32
  • [39] AN INNOVATIVE ECOLOGICAL HYBRID REFRIGERATION CYCLE FOR HIGH POWER REFRIGERATION FACILITY
    Cyklis, Piotr
    Janisz, Karina
    CHEMICAL AND PROCESS ENGINEERING-INZYNIERIA CHEMICZNA I PROCESOWA, 2015, 36 (03): : 321 - 330
  • [40] A review on the performance of nanoparticles suspended with refrigerants and lubricating oils in refrigeration systems
    Saidur, R.
    Kazi, S. N.
    Hossain, M. S.
    Rahman, M. M.
    Mohammed, H. A.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (01): : 310 - 323