Seismic-Resistant Performance of Double Built-Up T Moment Connections

被引:0
|
作者
Herrera, Ricardo [1 ]
Nunez, Eduardo [2 ]
Hernandez, Matias [2 ]
机构
[1] Univ Chile, Dept Civil Engn, Santiago 2002, Chile
[2] Univ Catolica Santisima Concepcion, Dept Civil Engn, Concepcion 4030000, Chile
关键词
Built-up; T-stub; Moment connection; Finite-element method (FEM); Cyclic behavior; Experimental research; STUB CONNECTIONS; BEHAVIOR; COMPONENTS; FRAMES;
D O I
10.1061/JSENDH.STENG-13318
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The double-T moment connection is considered in the AISC Seismic Provisions for use in steel structures subjected to seismic forces. Nowadays, the use of double-T connections requires the use of hot-rolled T-sections, which limits the optimal design. Hence, if there is a need to increase the flange or web thickness, this can only be achieved by increasing the entire T-section size, providing oversized and costly sections. In this research, this issue is addressed by studying the use of double built-up T (DBT) moment connections. Two full-scale specimens, as a complement to the five specimens previously tested by the authors, one considering a web panel zone failure mechanism and the other with the failure mechanism controlled simultaneously by the web panel zone and beam plastic hinging (balanced failure), were subjected to cyclic loading using the protocol established in AISC Seismic Provisions. Then, seven numerical models in ANSYS were developed, to reproduce the conditions of the seven specimens tested. The results showed an acceptable behavior of the specimens when the plastic hinge in the beam is the failure mechanism criterion controlling the seismic design. The specimens with a weak connection reached a lower resistance in comparison to the specimens with a weak panel zone and balanced failure. However, all specimens were able to achieve a story drift ratio of 4% with significant strength. The numerical models were calibrated from experimental data. No failures in the welds were observed in the specimens tested, which included full-penetration and fillet-welded specimens; therefore, the use of built-up T-stubs is reliable if their design is performed using a capacity design.
引用
收藏
页数:20
相关论文
共 50 条
  • [41] Seismic risk analysis: a method for the vulnerability assessment of built-up areas
    Giovinazzi, S
    Lagomarsino, S
    SAFETY AND RELIABILITY, VOLS 1 AND 2, 2003, : 671 - 679
  • [42] Experimental results for seismic resistant steel moment frame connections
    Univ of Washington, Seattle, United States
    J Struct Eng, 6 (581-588):
  • [43] Experimental results for seismic resistant steel moment frame connections
    Roeder, CW
    Foutch, DA
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1996, 122 (06): : 581 - 588
  • [44] Seismic-Resistant Bridge Columns with Ultrahigh-Performance Concrete Segments
    Ichikawa, Shota
    Matsuzaki, Hiroshi
    Moustafa, Ayman
    ElGawady, Mohamed A.
    Kawashima, Kazuhiko
    JOURNAL OF BRIDGE ENGINEERING, 2016, 21 (09)
  • [45] Stiffness modeling of bolted thick built-up T-stub connections including secondary prying effect
    Hantouche, Elie G.
    Abboud, Nabil H.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2014, 95 : 279 - 289
  • [46] Built-up sleep pressure drives the loss of neuronal connections during slumber
    Suppermpool, Anya
    Lyons, Declan G.
    NATURE, 2024,
  • [48] Seismic performance of moment connections in steel moment frames with HSS columns
    Nunez, Eduardo
    Torres, Ronald
    Herrera, Ricardo
    STEEL AND COMPOSITE STRUCTURES, 2017, 25 (03): : 271 - 286
  • [49] Bending Moment Capacity of Cold-Formed Steel Built-Up Beams
    Mohamed Ghannam
    International Journal of Steel Structures, 2019, 19 : 660 - 671
  • [50] A study on structural performance of new shape built-up square column-to-beam connections with through diaphragms
    Kim, Sun-Hee
    Lee, Hyun-Chyul
    Kwon, Youn-Sang
    Yom, Kyong-Soo
    Choi, Sung-Mo
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2011, 43 (SUPPL. 2): : 362 - 367