Seismic-Resistant Performance of Double Built-Up T Moment Connections

被引:0
|
作者
Herrera, Ricardo [1 ]
Nunez, Eduardo [2 ]
Hernandez, Matias [2 ]
机构
[1] Univ Chile, Dept Civil Engn, Santiago 2002, Chile
[2] Univ Catolica Santisima Concepcion, Dept Civil Engn, Concepcion 4030000, Chile
关键词
Built-up; T-stub; Moment connection; Finite-element method (FEM); Cyclic behavior; Experimental research; STUB CONNECTIONS; BEHAVIOR; COMPONENTS; FRAMES;
D O I
10.1061/JSENDH.STENG-13318
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The double-T moment connection is considered in the AISC Seismic Provisions for use in steel structures subjected to seismic forces. Nowadays, the use of double-T connections requires the use of hot-rolled T-sections, which limits the optimal design. Hence, if there is a need to increase the flange or web thickness, this can only be achieved by increasing the entire T-section size, providing oversized and costly sections. In this research, this issue is addressed by studying the use of double built-up T (DBT) moment connections. Two full-scale specimens, as a complement to the five specimens previously tested by the authors, one considering a web panel zone failure mechanism and the other with the failure mechanism controlled simultaneously by the web panel zone and beam plastic hinging (balanced failure), were subjected to cyclic loading using the protocol established in AISC Seismic Provisions. Then, seven numerical models in ANSYS were developed, to reproduce the conditions of the seven specimens tested. The results showed an acceptable behavior of the specimens when the plastic hinge in the beam is the failure mechanism criterion controlling the seismic design. The specimens with a weak connection reached a lower resistance in comparison to the specimens with a weak panel zone and balanced failure. However, all specimens were able to achieve a story drift ratio of 4% with significant strength. The numerical models were calibrated from experimental data. No failures in the welds were observed in the specimens tested, which included full-penetration and fillet-welded specimens; therefore, the use of built-up T-stubs is reliable if their design is performed using a capacity design.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Performance of built-up T-stubs for Double T moment connections
    Herrera, Ricardo A.
    Bravo, Miguel
    Gomez, Gustavo
    Aedo, Gonzalo
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2013, 88 : 289 - 295
  • [2] Experimental performance of double built-up T moment connections under cyclic loading
    Herrera, Ricardo
    Salas, Constanza
    Felipe Beltran, Juan
    Nunez, Eduardo
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 138 : 742 - 749
  • [3] Performance under cyclic load of built-up T-stubs for Double T moment connections
    Bravo, Miguel A.
    Herrera, Ricardo A.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2014, 103 : 117 - 130
  • [4] Seismic performance of pre-northridge welded steel moment connections to built-up box columns
    Kim, Taejin
    Stojadinovic, Bozidar
    Whittaker, Andrew S.
    JOURNAL OF STRUCTURAL ENGINEERING, 2008, 134 (02) : 289 - 299
  • [5] Seismic retrofitting of beam to double-I built-up column moment connections by lateral T-stiffeners: Experimental and numerical study
    Ayoubi, Mohammad Reza
    Ghobadi, Mohammad Soheil
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2023, 205
  • [6] Study on seismic performance of built-up double angle X-braces
    Ran H.
    Zhang C.
    Ma Y.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2023, 44 (06): : 186 - 198
  • [7] Experimental verification of seismic performance of built-up beam-to-column connections with ductile detail
    Oh, Sang-Hoon
    Kim, Yun-Hyeok
    Ryu, Hong-Sik
    Kim, Young-Ju
    Park, Hae-Yong
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 176
  • [8] Seismic performance of double-sided plate-reinforced connections between steel beams and built-up box columns
    Shi, Gang
    Jiang, Sheng
    Zhang, Naizhou
    Hou, Lintao
    Zhao, Huatian
    THIN-WALLED STRUCTURES, 2025, 208
  • [9] Posttensioned seismic-resistant connections for steel frames
    Ricles, JM
    Sause, R
    Garlock, MM
    Zhao, C
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2001, 127 (02): : 113 - 121
  • [10] Cyclic behavior of steel moment connections with built-up columns in weak direction
    Mohammadi, S.
    Ghassemieh, M.
    Mirghaderi, S. R.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 172