The four-quadrant phase-mask coronagraph: White light laboratory results with an achromatic device

被引:0
|
作者
Mawet, D. [1 ]
Riaud, P. [1 ]
Baudrand, J. [2 ]
Baudoz, P. [2 ]
Boccaletti, A. [2 ]
Dupuis, O. [2 ]
Rouan, D. [2 ]
机构
[1] Université de Liège, 17 Allée du 6 Août, 4000 Sart-Tilman, Belgium
[2] LESIA, Observatoire de Paris-Meudon, 5 pl J. Janssen, 92195 Meudon, France
来源
Astronomy and Astrophysics | 2006年 / 448卷 / 02期
关键词
Achromatic coronagraphs are the subject of intensive research since they will be mandatory for many programs which aim at detecting and characterizing exoplanets. We report a laboratory experiment assessing the performance of the Four-Quadrant Phase-Mask coronagraph (FQPM) over a broadband wavelength range (R 2). The achromatization of the FQPM is provided by achromatic halfwave plates (HWP). These phase shifters combine birefringent plates made of different materials with properly chosen thicknesses. The HWP thickness control is relaxed by two orders of magnitudes with respect to the classical (non-birefringent) dispersive plate approach. In our experiment we used a two stage stack of Quartz and MgF2. This combination allows to cover a large spectral range in the visible (500-900 nm) with a small phase error residual around π (0.12 rad rms). With this achromatization; we obtained an attenuation of 755 on the white light PSF peak. This solution is directly applicable to ground-based telescopes using high order adaptive optics such as the ESO's VLT-Planet Finder project and could easily be transposed in the mid-infrared domain for future space-based missions like DARW1N/TPF. © ESO 2006;
D O I
暂无
中图分类号
学科分类号
摘要
Journal article (JA)
引用
收藏
页码:801 / 808
相关论文
共 26 条
  • [21] Unbalanced nulling interferometer with four-quadrant phase mask
    Kobayashi, Takuji
    Nishikawa, Jun
    Tanaka, Yosuke
    Kurokawa, Takashi
    Kashiwagi, Ken
    Murakami, Naoshi
    Baba, Naoshi
    Hashimoto, Nobuyuki
    22ND INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, PTS 1-3, 2012, 8421
  • [22] Achromatic four quadrant phase mask using the dispersion of form birefringence
    Mawet, D
    Lenaerts, C
    Moreau, V
    Renotte, Y
    Rouan, D
    Surdej, J
    HIGH-CONTRAST IMAGING FOR EXO-PLANET DETECTION, 2003, 4860 : 182 - 191
  • [23] Ground-based coronagraphy: Performance of a four-quadrant phase mask
    Puga, E
    Feldt, M
    Henning, T
    Kley, EB
    Costa, JB
    Bizenberger, P
    Hippler, S
    HIGH-CONTRAST IMAGING FOR EXO-PLANET DETECTION, 2003, 4860 : 387 - 394
  • [24] Feasibility of the four-quadrant phase mask in the mid-infrared on the James!Webb Space Telescope
    Baudoz, P
    Boccaletti, A
    Riaud, P
    Cavarroc, C
    Baudrand, J
    Reess, JM
    Rouan, D
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF THE PACIFIC, 2006, 118 (843) : 765 - 773
  • [25] Laboratory validation of the dual-zone phase mask coronagraph in broadband light at the high-contrast imaging THD testbed
    Delorme, J. R.
    N'Diaye, M.
    Galicher, R.
    Dohlen, K.
    Baudoz, P.
    Caillat, A.
    Rousset, G.
    Soummer, R.
    Dupuis, O.
    ASTRONOMY & ASTROPHYSICS, 2016, 592
  • [26] Increasing the raw contrast of VLT/SPHERE with the dark hole technique: III. Broadband reference differential imaging of HR4796 using a four-quadrant phase mask
    Galicher R.
    Potier A.
    Mazoyer J.
    Wahhaj Z.
    Baudoz P.
    Chauvin G.
    Astronomy and Astrophysics, 2024, 686