Calibration of MAJIS (Moons and Jupiter Imaging Spectrometer). IV. Radiometric calibration (invited)

被引:2
|
作者
Langevin, Y. [1 ]
Poulet, F. [1 ]
Piccioni, G. [2 ]
Filacchione, G. [2 ]
Dumesnil, C. [1 ]
Tosi, F. [2 ]
Carter, J. [1 ]
Barbis, A. [3 ]
Haffoud, P. [1 ]
Tommasi, L. [3 ]
Vincendon, M. [1 ]
De Angelis, S. [2 ]
Guerri, I. [3 ]
Pilorget, C. [1 ]
Rodriguez, S. [4 ]
Stefani, S. [2 ]
Bolsee, D. [5 ]
Cisneros, M. [5 ]
Van Laeken, L. [5 ]
Pereira, N. [5 ]
Carapelle, A. [6 ]
机构
[1] Univ Paris Saclay, Inst Astrophys Spatiale, CNRS, F-91400 Orsay, France
[2] Ist Nazl Astrofis, Ist Astrofis & Planetol Spaziali, I-00133 Rome, Italy
[3] Leonardo Co, Via Officine Galileo 1, I-50013 Campi Bisenzio, Italy
[4] Univ Paris Cite, Inst Phys Globe Paris, CNRS, F-75005 Paris, France
[5] Royal Belgian Inst Space Aeron, Ave Circulaire 3, B-1180 Brussels, Belgium
[6] Univ Liege, Ctr Spatial Liege, Ave Pre Aily, B-4031 Liege, Belgium
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2024年 / 95卷 / 11期
关键词
DETECTORS; NOISE; GAIN;
D O I
10.1063/5.0202702
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The MAJIS (Moons and Jupiter Imaging Spectrometer) instrument is an imaging spectrometer on-board the JUICE (JUpiter ICy moons Explorer) spacecraft. MAJIS covers the spectral range from 0.5 to 5.54 mu m with two channels [visible-near infrared (VISNIR) and IR]. A comprehensive campaign of on-ground MAJIS calibration was conducted in August and September 2021 in the IAS (Institut d'Astrophysique Spatiale, CNRS/Universit & eacute; Paris-Saclay) facilities. In this article, we present the results relevant for the radiometric calibration of MAJIS. Due to the specific characteristics of the MAJIS detectors (H1RG from Teledyne), an extensive detector characterization campaign was implemented for both the VISNIR and IR detectors before integration so as to validate readout procedures providing precision and accuracy. The characterization also provided critical information on linearity and operability as a function of the integration time and operating temperature. The radiometric calibration of the integrated MAJIS instrument focused on the determination of the instrument transfer function in terms of DN output per unit of radiance for each MAJIS data element as a function of its position in the field of view of MAJIS and its central wavelength. The radiometric calibration of the VISNIR channel required a specific procedure due to stray light at short wavelengths. Observations of an internal calibration source during calibration and after launch (April 14, 2023) showed that there were minor changes in both the VISNIR and IR channels. The instrument transfer functions to be used in flight have been updated on this basis.
引用
收藏
页数:28
相关论文
共 50 条
  • [21] RADIOMETRIC CALIBRATION FOR HDR IMAGING
    Sohaib, Ahmed
    Robles-Kelly, Antonio
    2015 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2015, : 2815 - 2819
  • [22] Preflight radiometric calibration of a carbon dioxide spectrometer
    Li, Shuai
    Li, Chengliang
    Xu, Shuyan
    Zhang, Hang
    Zheng, Yuquan
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2019, 30 (05)
  • [23] Study of radiometric calibration methods on a compact novel imaging guided FTIR spectrometer
    Dai, Xiaobing
    Liu, Xiangyan
    Gao, Pengcheng
    He, Xudong
    MIPPR 2013: REMOTE SENSING IMAGE PROCESSING, GEOGRAPHIC INFORMATION SYSTEMS, AND OTHER APPLICATIONS, 2013, 8921
  • [24] Experimental research for relative radiometric calibration of imaging spectrometer based on Savart plates
    Li, Qiwei
    Zhang, Chunmin
    Yan, Tingyu
    SECOND INTERNATIONAL CONFERENCE ON PHOTONICS AND OPTICAL ENGINEERING, 2017, 10256
  • [25] Radiometric calibration of the telescope and ultraviolet spectrometer SUMER on SOHO
    Hollandt, J
    Schuhle, U
    Paustian, W
    Curdt, W
    Kuhne, M
    Wende, B
    Wilhelm, K
    APPLIED OPTICS, 1996, 35 (25): : 5125 - 5133
  • [26] CALIBRATION ALGORITHMS FOR AN IMAGING SPECTROMETER
    Dell'Endice, Francesco
    2009 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, VOLS 1-5, 2009, : 332 - 335
  • [27] The Analysis of Radiometric calibration based on Long-wave infrared hyperspectral imaging spectrometer
    Yang Zhi-xiong
    Zheng Wei-jian
    Xia Fei
    Xia Zongze
    Lei Zhenggang
    Yu Chunchao
    FIFTH CONFERENCE ON FRONTIERS IN OPTICAL IMAGING TECHNOLOGY AND APPLICATIONS (FOI 2018), 2018, 10832
  • [28] Onboard absolute radiometric calibration and validation of the satellite calibration spectrometer on HY-1C
    Xu, He-yu
    Zhang, Li-ming
    Huang, Wen-xin
    Xu, Wei-wei
    Si, Xiao-long
    Chen, Hong-Yao
    Li, Xin
    Song, Qing-jun
    OPTICS EXPRESS, 2020, 28 (20) : 30015 - 30034
  • [29] Spectral and Radiometric Calibration Methods for Acousto-Optic Spectrometer
    Cheng Chi
    Zhao Huijie
    Guo Qi
    Li Ran
    ACTA OPTICA SINICA, 2024, 44 (09)
  • [30] Absolute radiometric calibration of digital imaging systems
    Brown, SW
    Larason, TC
    Habauzit, C
    Eppeldauer, GP
    Ohno, Y
    Lykke, KR
    SENSORS AND CAMERA SYSTEMS FOR SCIENTIFIC, INDUSTRIAL, AND DIGITAL PHOTOGRAPHY APPLICATIONS II, 2001, 4306 : 13 - 21