Mechanical Response Study of a Cross-Fault Water Conveyance Tunnel under the Combined Action of Faulting Dislocation and Seismic Loading

被引:0
|
作者
Zhang, Maochu [1 ,2 ,3 ]
Yan, Tianyou [1 ,2 ,3 ]
Cui, Zhen [3 ,4 ]
Li, Jianhe [1 ,2 ,3 ]
Xu, Ran [1 ,2 ,3 ]
机构
[1] Changjiang Design Grp Co Ltd, Wuhan 430010, Peoples R China
[2] Changjiang Survey Planning Design & Res Co Ltd, Wuhan 430010, Peoples R China
[3] State Key Lab Water Resources Engn & Management, Wuhan 430072, Peoples R China
[4] Chinese Acad Sci, Inst Rock & Soil Mech, State Key Lab Geomech & Geotech Engn, Wuhan 430071, Peoples R China
基金
中国博士后科学基金;
关键词
cross-fault tunnel; mechanical response; faulting dislocation; seismic loading; numerical simulation; MOUNTAIN TUNNELS; DAMAGE ANALYSIS;
D O I
10.3390/w16202876
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper investigated the response of a cross-fault water conveyance tunnel under the combined action of faulting dislocation and seismic loading. The current work studied the mechanical properties of the wall rock-lining contact surface. Finite difference method (FDM) code was used for the numerical simulation test to reproduce the shear test and calibrate the parameters. In the analysis of the combined faulting dislocation and strong earthquake impact on the cross-fault tunnel, the FDM was used with special consideration of the wall rock-lining interaction. The result showed that the Coulomb contact model in the FDM code could satisfactorily simulate the shear behavior of wall rock-lining contact surface. In the mechanical response calculation of the cross-fault tunnel under the faulting dislocation-seismic loading action, the magnitude of the initial faulting distance had a significant effect on the seismic relative deformation of the tunnel. The permanent deformation caused by the seismic loading increased with the initial faulting dislocation. The position of the maximum shear stress on the contact interface was related to the faulting dislocation mode, and it was distributed on the side of the tunnel squeezed by the active plate. In the high seismic risk regions with extensive development of active faults, it was necessary to consider the initial crack caused by the faulting dislocation in the stability evaluation of the cross-fault tunnel. Then, the seismic resistance study of the tunnel was followed.
引用
收藏
页数:15
相关论文
共 34 条
  • [31] Study on Response and Influencing Factors of Shield Single/Twin Tunnel under Seismic Loading using FLAC 3D
    Li, Song
    Chen, Yanxiang
    Huang, Linhua
    Guo, Enping
    SHOCK AND VIBRATION, 2022, 2022
  • [32] The damage mode and forced response characteristics of articulated lining structure: A case study of metro tunnel under a reverse fault action
    Zhang, Zhiqiang
    Zhang, Yang
    Wei, Ronghua
    Yin, Chao
    Zhang, Heng
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2023, 140
  • [33] Study on the mechanical properties of deep-buried loess seismic-isolated tunnel under vertical incidence P-wave action
    Sun, Haodong
    Cheng, Xuansheng
    Zhang, Shanglong
    Xia, Peiyan
    Ding, Kai
    Structures, 2025, 75
  • [34] Study on structural response of water-back plate under the combined action of shock wave and bubble loads generated by cylindrical charge in deep-water environment
    Ma, Teng
    Wang, Jinxiang
    Liu, Liangtao
    Li, Heng
    Tang, Kui
    Gu, Yangchen
    Zhang, Yifan
    THIN-WALLED STRUCTURES, 2024, 194