Numerical characterisation of the convective heat transfer and fluid flow for inline woven wire meshes in solar volumetric receivers

被引:1
|
作者
Sanchez-Senoran, Daniel [1 ,2 ]
Reyes-Belmonte, Miguel A. [2 ]
Farchado, Meryem [3 ]
Casanova, Marina [4 ]
Avila-Marin, Antonio L. [1 ]
机构
[1] CIEMAT, Point Focus Solar Thermal Technol Unit, Plataforma Solar Almeria, Avda Complutense 40, E-28040 Madrid, Spain
[2] Rey Juan Carlos Univ, Chem Energy & Mech Technol, C Tulipan S-N, E-28933 Madrid, Spain
[3] CIEMAT, Mat Concentrating Solar Thermal Technol Unit, Plataforma Solar Almeria, Avda Complutense 40, E-28040 Madrid, Spain
[4] CIEMAT, Thermal Energy Storage Unit, Plataforma Solar Almeria, Crta Senes Km 4-5, E-04200 Almeria, Spain
关键词
Volumetric receivers; Central receiver system; CFD simulations; Concentrated solar power; Differential pressure per unit length; Heat transfer coefficient; PRESSURE-DROP; TRANSFER COEFFICIENT; SIMULATION; AIR; REGENERATOR; MATRIX; FOAMS;
D O I
10.1016/j.icheatmasstransfer.2024.108269
中图分类号
O414.1 [热力学];
学科分类号
摘要
In solar tower systems, metallic woven wire meshes following an inline arrangement are a promising geometry for commercial application in open volumetric receivers (OVRs). To assess their potential, two main parameters, with two different methodologies, need to be analysed in depth: the convective heat transfer coefficient (HTC) and the pressure drop per unit length (Delta P/L). In this study, three wire diameters, 0.7, 0.4 and 0.1 mm, with a fixed porosity of 80 %, have been selected to establish a baseline for the HTC and the Delta P/L sensitivity studies. In the HTC methodology, six air inlet velocities between 0.5 and 5 m/s, and constant solid matrix temperatures of 700, 1100 and 1500 K, have been evaluated. For the Delta P/L methodology, six air inlet velocities between 0.5 and 5 m/s and a constant solid matrix temperature of 300 K was used. For each thermo-fluid-dynamic attribute, HTC and Delta P/L, and each wire diameter (0.7, 0.4 and 0.1 mm) with 80 % porosity, an individual correlation is presented resulting in a total of six individual correlations. In addition, two generalised correlations, one of each thermo-fluid-dynamic attribute, for 80 % porosity and wire diameter ranging from 0.1 to 0.7 mm are shown, taking into account the specific geometrical parameters of the wire mesh lattices. The generalised correlations obtained in the study present deviations under 7 % from the CFD results in both thermo-fluid-dynamic attributes, showing results as good as the ones obtained with the individual correlations. As a result, it is demonstrated that the geometrical parameters must be included in the correlations used to predict the thermo-fluid-dynamic attributes in wire mesh lattices. All the correlations have been validated through porous models with good agreement and they would work for future optimisation studies.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Experimental investigation to natural convective heat transfer in wire-woven bulk Kagome truss
    School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, China
    不详
    不详
    不详
    Lu, T., 1600, Xi'an Jiaotong University (48):
  • [32] Numerical investigation on heat transfer characteristics of the viscoelastic fluid flow during wire coating process
    Gouran, S.
    RESULTS IN ENGINEERING, 2024, 21
  • [33] Analytical and numerical solution of MHD flow and heat transfer of a viscoelastic fluid in wire coating analysis
    Kumar, T. Sravan
    DISCOVER APPLIED SCIENCES, 2025, 7 (02)
  • [34] Numerical analysis of heat transfer and fluid flow in SA-NG-GMAW with additional wire
    Wu, Yejun
    Wang, Jiayou
    Xu, Guoxiang
    Jiang, Yuqin
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2025, 137 (3-4): : 1421 - 1436
  • [35] Fluid flow and convective heat transfer to fluids at supercritical pressure
    Jackson, J. D.
    NUCLEAR ENGINEERING AND DESIGN, 2013, 264 : 24 - 40
  • [36] Fluid flow and convective heat transfer in a vertical porous annulus
    Jiang, PX
    Wang, BX
    Luo, DA
    Ren, ZP
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 1996, 30 (03) : 305 - 320
  • [37] Fluid Flow and Convective Heat Transfer in a Water Chemical Condenser
    Kriraa, Mounir
    Souhar, Khalid
    Achemlal, Driss
    Yassine, Youssef Ait
    Farchi, Abdelmajid
    FDMP-FLUID DYNAMICS & MATERIALS PROCESSING, 2020, 16 (02): : 199 - 209
  • [38] Interstitial convective heat transfer for fluid flow through porous
    Patiño-Carrillo, LA
    Espinoza-Bejarano, HJ
    INGENIERIA HIDRAULICA EN MEXICO, 2004, 19 (02): : 37 - 51
  • [39] Flow and Heat Transfer in Sisko Fluid with Convective Boundary Condition
    Malik, Rabia
    Khan, Masood
    Munir, Asif
    Khan, Waqar Azeem
    PLOS ONE, 2014, 9 (10):
  • [40] CONVECTIVE HEAT TRANSFER ENHANCEMENT IN SOLAR RECEIVERS USING MINIMUM ENTROPY GENERATION OPTIMIZATION
    Li, Qi
    Yuan, Xigang
    Neveu, Pierre
    Flamant, Gilles
    PROCEEDINGS OF THE ASME 5TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY 2011, PTS A-C, 2012, : 1965 - 1974