Model Test Study on Deformation and Failure of Metro Shield Tunnel under Normal Faulting

被引:0
|
作者
Li, Hanyuan [1 ,2 ]
Li, Xinggao [1 ,2 ]
Wang, Jie [1 ,2 ]
Yang, Yi [1 ,2 ]
Liu, Hao [3 ]
机构
[1] Key Laboratory of Urban Underground Engineering, Ministry of Education, Beijing Jiaotong University, Beijing,100044, China
[2] School of Civil Engineering, Beijing Jiaotong University, Beijing,100044, China
[3] Jinan Rail Transit Group Co. Ltd., Jinan,250101, China
基金
中国国家自然科学基金;
关键词
Faulting - Fracture - Fracture mechanics - Shielding - Structural design - Tunnel linings;
D O I
10.16339/j.cnki.hdxbzkb.2024049
中图分类号
学科分类号
摘要
To reveal the deformation and failure characteristics of the metro shield tunnel overpassing buried fault, a self-designed loading test device for faulting simulation was used to carry out a 1∶25 geometric scale cross-fault shield tunnel model test. The mechanical response law and deformation failure characteristics of the shield tunnel under normal faulting were analyzed. The test results show that under 2 cm normal faulting, the longitudinal differential deformation of the tunnel shows a nonlinear increasing trend. The opening of the circumferential joint is mainly located at the vault of the footwall tunnel. The arch bottom of the hanging wall tunnel and the peak opening of the circumferential joints have exceeded the waterproof limit of the joints. The diameter convergence deformation of the segment lining at the junction of the fault extension line and the tunnel occurs severely. The stress state of the outer side of the arch waist of the tunnel lining is tensioned, while the outer side of the vault and the arch waist are compressed. The contact pressure between the tunnel and the stratum is greatly affected by the faulting, and there are surrounding rock compression and loosening zones. However, the peak value of contact pressure is relatively limited. Tensile fracture of the circumferential joint, longitudinal cracking of the segment, and joint deformation are the main deformation and failure characteristics of the shield tunnel. The probability of oblique shear failure and local crushing failure is low. Based on the longitudinal deformation and failure characteristics of shield tunnels, the joints deformation and the tensile fracture of the circumferential joint should be taken as the main control indexes to define the structural failure of cross-fault shield tunnels. Based on the deformation and failure characteristics of segmental lining, suggestions on structural design and countermeasures of cross-fault shield tunnel are proposed. © 2024 Hunan University. All rights reserved.
引用
收藏
页码:76 / 87
相关论文
共 50 条
  • [21] Investigation of deformation of shield tunnel based on large-scale model test
    Tsuno K.
    Kinoshita K.
    Ushida T.
    Quarterly Report of RTRI (Railway Technical Research Institute), 2020, 61 (01): : 16 - 21
  • [22] Experimental study on lining response of metro shield tunnel under the influence of ground cavity
    Guan, Feng
    Wei, Duqiang
    Lei, Jinshan
    Shi, Yufeng
    Cao, Chengwei
    Journal of Railway Science and Engineering, 2022, 19 (02): : 461 - 469
  • [23] Safety assessment model of metro EPB shield tunnel construction
    You, Pengfei
    Mou, Ruifang
    Yanshilixue Yu Gongcheng Xuebao/Chinese Journal of Rock Mechanics and Engineering, 2010, 29 (SUPPL. 1): : 2663 - 2668
  • [24] Failure analysis and dislocation-resistant design parameters of mining tunnel under normal faulting
    Wang, Qi
    Geng, Ping
    Li, Peisong
    Wang, Tianqiang
    Sun, Wenhao
    ENGINEERING FAILURE ANALYSIS, 2023, 143
  • [25] Study on the Interaction of Metro Shield Tunnel Construction Under-Crossing the Existing Longhai Railway
    Bao Liu
    Danhui Xi
    Ping Xu
    Geotechnical and Geological Engineering, 2020, 38 : 2159 - 2168
  • [26] Model test on the deformation law of shield tunnel underpassing high speed railway roadbed
    Liu Yong
    Zhou Yi-sheng
    Suo Xiao-ming
    Fan Hao-bo
    Cao Yi-ze
    Du Zhi-tian
    ROCK AND SOIL MECHANICS, 2023, 44 (04) : 941 - 951
  • [27] Study on Flexural Rigidity of Segment Joints in Metro Shield Tunnel
    Yang, Dejian
    Wang, Xin
    PROGRESS IN CIVIL ENGINEERING, PTS 1-4, 2012, 170-173 : 1716 - 1721
  • [28] Study on the Interaction of Metro Shield Tunnel Construction Under-Crossing the Existing Longhai Railway
    Liu, Bao
    Xi, Danhui
    Xu, Ping
    GEOTECHNICAL AND GEOLOGICAL ENGINEERING, 2020, 38 (02) : 2159 - 2168
  • [29] Case study on the model test of staggered-jointed assembling shield tunnel structure reinforced by bonded steel plates under large deformation
    Liu, Xue-zeng
    Lai, Hao-ran
    Sang, Yun-long
    2019 INTERNATIONAL CONFERENCE ON ADVANCES IN CIVIL ENGINEERING, ENERGY RESOURCES AND ENVIRONMENT ENGINEERING, 2019, 330
  • [30] Model test study on the mechanical response of metro tunnel to land subsidence
    Huang, Qiangbing
    Gou, Yuxuan
    Xue, Liming
    Yuan, Yi
    Yang, Bo
    Peng, Jianbing
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2023, 140