Behaviour of timber infilled cold-formed steel tubular short columns under monotonic and cyclic compression: An experimental study

被引:0
|
作者
Thamboo, Julian [1 ]
Navaratnam, Satheeskumar [2 ]
Poologanathan, Keerthan [3 ]
机构
[1] South Eastern Univ Sri Lanka, Dept Civil Engn, Oluvil 32360, Sri Lanka
[2] RMIT Univ, Sch Engn, Melbourne 3000, Australia
[3] Northumbria Univ, Fac Engn & Environm, Newcastle Upon Tyne NE1 8ST, England
关键词
TIST columns; Timber column; Cold-formed steel; Cyclic compression; Monotonic compression; Axial capacity; DESIGN; PERFORMANCE; TUBES;
D O I
10.1016/j.istruc.2024.107873
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Timber-steel composite elements have shown to be effective, compared to traditional timber elements, as they are relatively lighter and equally efficient in resisting structural effects. This paper reports the outcome of an experimental study conducted to evaluate the performance of Timber infilled steel tubular (TIST) columns under axial compression. Two types of TIST column sections (square and circular) were fabricated and tested, along with two different types of steel tubular thicknesses (1.4 mm and 2.4 mm). In total, 40 TIST column specimens were subjected to monotonic and cyclic compression. The experimental findings are reported in terms of failure modes, axial compression resistance and load-deformation characteristics gathered from the tested TIST column specimens. All the tested TIST columns have failed by local axial buckling of steel tubes, followed by crushing or combined crushing and shear failure of timber sections. Further, the load-deformation characteristics observed in monotonic and cyclic loaded TIST columns are different, where slightly less axial load capacities were achieved in cyclic loaded columns, with relatively higher axial deformation characteristics. The cyclic compression capacities of the TIST columns are about 5-15 % lower than the corresponding monotonic capacities. In addition, the shape of the TIST section and slenderness of the steel tubes affect the axial compression behaviour of the columns. The design formulations suggested to determine the axial resistances of concrete infilled steel tubular (CIST) sections were used to examine the axial resistance of TIST columns, where instead of concrete properties, the infilled timber properties have been substituted. Subsequently, the considered formulations have been shown to conservatively predict the axial resistance of the TIST column specimens.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Experimental study of sheathed cold-formed steel beam–columns
    Kyprianou, Constantinos
    Kyvelou, Pinelopi
    Gardner, Leroy
    Nethercot, David A.
    Thin-Walled Structures, 2021, 166
  • [22] Study on behaviour of Z-stiffened Columns with and without Lips Using Cold-formed Steel under Axial Compression
    Renuka, R.
    Kalaiselvi, S.
    Adhiyaman, M.
    Kumar, G. Arun
    INTERNATIONAL JOURNAL OF EARLY CHILDHOOD SPECIAL EDUCATION, 2022, 14 (03) : 753 - 760
  • [23] Cold-formed ferritic stainless steel perforated tubular stub columns: Behaviour and design
    Anbarasu, M.
    Subalakshmi, M.
    Dar, M. Adil
    Hassanein, M. F.
    THIN-WALLED STRUCTURES, 2022, 170
  • [24] ANALYSIS OF SQUARE CONCRETE-FILLED COLD-FORMED STEEL TUBULAR COLUMNS UNDER AXIAL CYCLIC LOADING
    Buachare, Chinnapat
    Hansapinyo, Chayanon
    Ueatrongchit, Nutchanok
    INTERNATIONAL JOURNAL OF GEOMATE, 2018, 15 (47): : 74 - 80
  • [25] Studies on cold-formed steel battened box columns under axial compression
    Beulah Gnana Ananthi, G.
    Journal of Structural Engineering (India), 2017, 44 (02): : 148 - 157
  • [26] Closed built-up cold-formed steel columns under compression
    Craveiro, Hélder D.
    Rahnavard, Rohola
    Santiago, Aldina
    Laím, Luís
    Simões, Rui
    ce/papers, 2023, 6 (3-4) : 1941 - 1946
  • [27] Behaviour of cold-formed steel concrete infilled RHS connections and frames
    Prabhavathy, RA
    Knight, GMS
    STEEL AND COMPOSITE STRUCTURES, 2006, 6 (01): : 71 - 85
  • [28] Behaviour of high strength cold-formed steel columns under elevated temperatures
    Chen, Ju
    Jin, Wei-Liang
    Gongcheng Lixue/Engineering Mechanics, 2009, 26 (12): : 167 - 174
  • [29] Experimental study on distortional buckling of high strength cold-formed steel lipped channel columns under axial compression
    Xi'an University of Architecture and Technology, Xi'an 710055, China
    不详
    不详
    Jianzhu Jiegou Xuebao, 2006, 3 (10-17):
  • [30] Behaviour of wrapped cold-formed steel columns under different loading conditions
    Baabu, B. Hari
    Sreenath, S.
    INTERNATIONAL CONFERENCE ON CIVIL ENGINEERING AND INFRASTRUCTURAL ISSUES IN EMERGING ECONOMIES (ICCIEE 2017), 2017, 80