Development of a circulating fluidized bed for a 100 kg/day waste plastic pyrolysis-combustion system

被引:0
|
作者
Kim, Daewook [1 ]
Yoon, Young Min [2 ]
Jang, Jae Jun [3 ]
Choi, Yujin [1 ]
Won, Yooseob [1 ]
Ryu, Ho-Jung [1 ]
Nam, Hyungseok [2 ]
Lee, Doyeon [4 ]
Choi, Jeong-Hoo [5 ]
Hwang, Byungwook [1 ]
机构
[1] Korea Inst Energy Res, 152 Gajeong Ro, Daejeon 34129, South Korea
[2] Kyungpook Natl Univ, 80 Daehak Ro, Daegu 41566, South Korea
[3] Sungkyunkwan Univ, 2066 Seobu Ro, Suwon 16419, South Korea
[4] Hanbat Natl Univ, 125 Donseodae Ro, Daejeon 34158, South Korea
[5] Konkuk Univ, 120 Neungdong Ro, Seoul 05029, South Korea
关键词
Waste plastic; Pyrolysis; Combustion; Circulating fluidized bed; Polypropylene; PRESSURE-DROP; RECOVERY; FLOW; POLYPROPYLENE; POLYETHYLENE; POLYOLEFINS;
D O I
10.1016/j.cej.2024.156257
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The aim of this study was to develop a 100 kg/day plastic waste pyrolysis-combustion circulating fluidized bed (CFB) system. The CFB was designed to provide heat from the combustor (semi-riser type) to the pyrolyzer (bubbling fluidized bed (BFB)) through heat carriers in high efficiency. A 100 kg/day scale system, including an oil condensation facility, was constructed and operated continuously for 34.5 hrs. Pelletized polypropylene was supplied to the pyrolyzer as plastic waste. The temperature in the pyrolyzer and plastic feeding rate were experimental variables. The weight percentage of low (C1-C12) 1 - C 12 ) and middle (C13-C22) 13 - C 22 ) carbon number components of the produced oil in CFB operated at 512-551 degrees C was 65.3 and 23.2 %, respectively. These were significantly higher than 34.6 and 28.4 % of the BFBs with similar temperatures previously, implying that the heat transfer in the CFB was more intense than that in the BFB. Compared to the BFB, only subtle differences in the pyrolysis gas yield was observed for CFB, which signified that the gas mixing between two reactors was minimized during the operation. Although no blockage was found in the CFB, clogging of condensers and pipelines occurred during low-temperature operation owing to the relatively low pour point of the product oil. The results in this study provide detailed and practical information on the temperature, pressure, product gas, oil, and clogging issues to better understand plastic pyrolysis in CFB.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Process characteristics investigation of simulated circulating fluidized bed combustion combined with coal pyrolysis
    Peng Liang
    Zhifeng Wang
    Jicheng Bi
    FUEL PROCESSING TECHNOLOGY, 2007, 88 (01) : 23 - 28
  • [22] From bubbling to circulating fluidized bed combustion-development and comparison
    Leckner, Bo
    HELIYON, 2024, 10 (13)
  • [23] Design and development of pressurised fluidized bed combustion system
    Reddy, D.N.
    Suneethi
    Reddy, Sujata
    Sarita
    Kalyani
    Journal of the Institution of Engineers (India), Part MC: Mechanical Engineering Division, 1991, 72 (pt 4):
  • [24] Development of a pressurized combustion system for fluidized bed coal
    Schrader, A
    Thielen, W
    Paulick, G
    Krautz, HJ
    FLUIDIZED BED COMBUSTION AND GASIFICATION: EXPERIENCE AND PROSPECTS, 2000, 1535 : 103 - 114
  • [25] A particle population balancing model for a circulating fluidized bed combustion system
    Redemann, K.
    Hartge, E. -U.
    Werther, Joachim
    POWDER TECHNOLOGY, 2009, 191 (1-2) : 78 - 90
  • [26] Study on dynamic behavior of the combustion system of a circulating fluidized bed boiler
    Ma, Su-Xia
    Yang, Xian-Yong
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2006, 26 (09): : 1 - 6
  • [27] Design of the PID Controller for Circulating Fluidized Bed Boiler Combustion System
    Hao Yuchun
    Li Donghai
    Tan Wen
    PROCEEDINGS OF THE 31ST CHINESE CONTROL CONFERENCE, 2012, : 4580 - 4585
  • [28] Pyrolysis of Real Packaging Plastic Waste Streams in a Fluidized-Bed Pilot Plant
    Genuino, Homer C.
    van Eijk, Marcel C. P.
    Kersten, Sascha R. A.
    Ruiz, M. Pilar
    ENERGY & FUELS, 2024, 38 (03) : 2188 - 2199
  • [29] Bed temperature control of a circulating fluidized bed combustion system using H∞ algorithm
    Jalali, Ali Akbar
    Hadavand, Aboozar
    2007 INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS, VOLS 1-6, 2007, : 1497 - 1501
  • [30] Multivariable Control strategy for Combustion System of Circulating Fluidized Bed Boiler
    Zhang, Yufei
    He, Huajie
    Zhu, Hanbo
    Su, Zhigang
    Hao, Yongsheng
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,