STUDY ON INVESTIGATION METHOD FOR FIRE-DAMAGED CONCRETE STRUCTURES USING WATERLESS PHENOLPHTHALEIN SOLUTION

被引:0
|
作者
Kinose T. [1 ]
Yoshida N. [2 ]
Atarashi D. [2 ]
Imamoto K.-I. [3 ]
机构
[1] Dept. of Chemistry, Interdisciplinary Graduate School of Science and Engineering, Shimane University
[2] Dept. of Architecture, Faculty of Engineering, Tokyo University of Science
来源
关键词
Carbonation; Concrete; Fire-damage investigation; Heated temperature; Moisture content; Phenolphthalein;
D O I
10.3130/aijs.89.489
中图分类号
学科分类号
摘要
Using of phenolphthalein solutions in fire-damaged concrete was investigated, leading to the following conclusions. 1. Traditionally, colorless areas appeared after spraying waterless phenolphthalein solution on fire-affected concrete, thought to be above 500°C. However, these areas were actually dry regions exposed to temperatures over 150°C. 2. Even in aged concrete structure undergoing carbonation and drying over time, it was determined that the use of a waterless PP solution enables the identification of areas experiencing temperatures above 150°C. 3. By using water-containing PP solution, the thermal decomposition range of CaCO3 where was heated above 600°C can be identified. © 2024 Architectural Institute of Japan. All rights reserved.
引用
收藏
页码:489 / 500
页数:11
相关论文
共 50 条