Experimental investigation on axial compressive performance of rectangular multi-cell stocky concrete-filled steel tubes stiffened with PBL

被引:0
|
作者
Xu, Aimin [1 ]
Men, Pengfei [2 ,3 ]
Liu, Dewei [4 ]
Di, Jin [2 ]
Wang, Jie [2 ]
Qin, Fengjiang [2 ]
机构
[1] Ningbo Highgrade Highway Construct Management Ctr, Ningbo 315192, Peoples R China
[2] Chongqing Univ, Sch Civil Engn, Key Lab New Technol Construct Cities Mt Area, Chongqing 400030, Peoples R China
[3] Hong Kong Polytech Univ, Dept Civil & Environm Engn, Hong Kong, Peoples R China
[4] Sichuan Shudao New Syst Rail Grp Co Ltd, Chengdu 610047, Peoples R China
基金
中国国家自然科学基金;
关键词
Multi-cell concrete-filled steel tube; Rectangular section; PBL stiffener; Stocky column; Compression tests; Design method; TUBULAR COLUMNS; STUB COLUMNS; BEHAVIOR; STRENGTH;
D O I
10.1016/j.cscm.2024.e03835
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An experimental investigation on the structural performance of rectangular multi-cell stocky concrete-filled steel tubes (CFSTs) stocky stiffened with perfobond leiste (PBL) under compression. Compression tests were conducted on 12 stocky CFSTs, varying concrete strengths, number of cells, and cross-section shapes. The tests discussed the failure process, load-deformation behaviours, section capacities, ductility factors, and core concrete enhancement factors of the specimens. It was found that all the 12 tested CFSTs experienced local bucking, and owing to the inclusion of PBL, the short sides of the steel tubes exhibited double-wave bulging, while the long sides showed multiple-wave bulging. With the enhancement of concrete strength from 29.4 to 65.1 MPa, the section capacity exhibited a significant increase of 18-30 %. As the cell number increased from 1 to 3, the section capacity increased by 1.35-1.59 times. When the cross-section of triple-cell CFSTs changed from the I-shape to the L-shape, the section capacity only increased by 3-9 %. Moreover, the enhancement factor of the core concrete and the confinement factor showed a significant correlation. The comparison between test capacities and predicted capacities using the methods given in design codes ANSI/AISC 360-16, EN 1994-1-1, and GB 50936-2014, as well as proposed by Zhang, revealed that the capacity ratios of predicted values to experimental values ranged from 0.63 to 0.89, indicating an overly conservative prediction. Considering the confinement factor, a modified design method, based on Zhang's method was proposed, to more accurately predict the section compressive capacity of rectangular multi-cell stocky CFSTs stiffened with PBL.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Concrete-filled square and rectangular FRP tubes under axial compression
    Ozbakkaloglu, Togay
    Oehlers, Deric J.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2008, 12 (04) : 469 - 477
  • [42] Polymer concrete-filled steel tubes under axial compression
    Oyawa, WO
    Sugiura, K
    Watanabe, E
    CONSTRUCTION AND BUILDING MATERIALS, 2001, 15 (04) : 187 - 197
  • [43] Experimental study on axial compressive behavior of concrete-filled corrugated steel tubular columns
    Tong, Jing-Zhong
    Zhang, Jia-Ming
    Yu, Chao-Qun
    Wu, Ruo-Min
    Tong, Gen-Shu
    Chen, Ming
    Gao, Wei
    ENGINEERING STRUCTURES, 2024, 313
  • [44] Axial behavior of ultra-high performance concrete (UHPC) filled stocky steel tubes with square sections
    Yan, Yanxiang
    Xu, Lihua
    Li, Biao
    Chi, Yin
    Yu, Min
    Zhou, Kaikai
    Song, Yang
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 158 : 417 - 428
  • [45] Damage assessment for performance-based design of rectangular concrete-filled steel tubes
    Tort, Cenk
    Hajjar, Jerome F.
    COMPOSITE CONSTRUCTION IN STEEL AND CONCRETE V, 2006, : 390 - +
  • [46] Experimental Behaviour of Recycled Aggregate Concrete-Filled Steel Tubes Under Axial Loading
    Vui Van Cao
    INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2019, 17 (8A) : 1341 - 1351
  • [47] Damage assessment of rectangular concrete-filled steel tubes for performance-based design
    Tort, C
    Hajjar, JF
    EARTHQUAKE SPECTRA, 2004, 20 (04) : 1317 - 1348
  • [48] Experimental Behaviour of Recycled Aggregate Concrete-Filled Steel Tubes Under Axial Loading
    Vui Van Cao
    International Journal of Civil Engineering, 2019, 17 : 1341 - 1351
  • [49] Experimental behavior of connections to concrete-filled steel tubes
    Schneider, SP
    Alostaz, YM
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1998, 45 (03) : 321 - 352
  • [50] Experimental Investigation on Rectangular Inclined Concrete-Filled Steel Tubular Stub Columns
    Ren, Qingxin
    Mo, Yaqing
    Jia, Lianguang
    Liu, Hong
    FRONTIERS OF GREEN BUILDING, MATERIALS AND CIVIL ENGINEERING, PTS 1-8, 2011, 71-78 : 826 - 829