Automatic Fetal Segmentation Designed on Computer-Aided Detection with Ultrasound Images

被引:0
|
作者
Govindarajan, Mohana Priya [1 ]
Bharathi, Sangeetha Subramaniam Karuppaiya [1 ]
机构
[1] SRM Inst Sci & Technol, Dept Comp Sci & Engn, Chennai 600026, Tamil Nadu, India
来源
CMC-COMPUTERS MATERIALS & CONTINUA | 2024年 / 81卷 / 02期
关键词
Fetal growth; segmentation; ultrasound images; computer-aided detection; gestational age; crown-rump length; head circumference;
D O I
10.32604/cmc.2024.055536
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In the present research, we describe a computer-aided detection (CAD) method aimed at automatic fetal head circumference (HC) measurement in 2D ultrasonography pictures during all trimesters of pregnancy. The HC might be utilized toward determining gestational age and tracking fetal development. This automated approach is particularly valuable in low-resource settings where access to trained sonographers is limited. The CAD system is divided into two steps: to begin, Haar-like characteristics were extracted from ultrasound pictures in order to train a classifier using random forests to find the fetal skull. We identified the HC using dynamic programming, an elliptical fit, and a Hough transform. The computer-aided detection (CAD) program was well-trained on 999 pictures (HC18 challenge data source), and then verified on 335 photos from all trimesters in an independent test set. A skilled sonographer and an expert in medicine personally marked the test set. We used the crown-rump length (CRL) measurement to calculate the reference gestational age (GA). In the first, second, and third trimesters, the median difference between the standard GA and the GA calculated by the skilled sonographer stayed at 0.7 +/- 2.7, 0.0 +/- 4.5, and 2.0 +/- 12.0 days, respectively. The regular duration variance between the baseline GA and the health investigator's GA remained 1.5 +/- 3.0, 1.9 +/- 5.0, and 4.0 +/- 14 a couple of days. The mean variance between the standard GA and the CAD system's GA remained between 0.5 and 5.0, with an additional variation of 2.9 to 12.5 days. The outcomes reveal that the computer-aided detection (CAD) program outperforms an expert sonographer. When paired with the classifications reported in the literature, the provided system achieves results that are comparable or even better. We have assessed and scheduled this computerized approach for HC evaluation, which includes information from all trimesters of gestation.
引用
收藏
页码:2967 / 2986
页数:20
相关论文
共 50 条
  • [41] Using shapes correlation for active contour segmentation of uterine fibroid ultrasound images in computer-aided therapy
    NI Bo
    HE Fa-zhi
    PAN Yi-teng
    YUAN Zhi-yong
    AppliedMathematics:AJournalofChineseUniversities, 2016, 31 (01) : 37 - 52
  • [42] Computer-aided automatic polarimeter
    Kiezun, A
    Jaroszewicz, LR
    Swillo, R
    POLARIMETRY AND ELLIPSOMETRY, 1997, 3094 : 100 - 104
  • [43] COMPUTER-AIDED AUTOMATIC DESIGN
    BONA, C
    GALLETTI, C
    LUCIFREDI, A
    MECHANISM AND MACHINE THEORY, 1973, 8 (04) : 437 - 456
  • [44] Automatic Pterygium Detection on Cornea Images to Enhance Computer-aided Cortical Cataract Grading System
    Gao, Xinting
    Wong, Damon Wing Kee
    Aryaputera, Aloysius Wishnu
    Sun, Ying
    Cheng, Ching-Yu
    Cheung, Carol
    Wong, Tien Yin
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 4434 - 4437
  • [45] Automatic segmentation of breast lesions for interaction in ultrasonic computer-aided diagnosis
    Huang, Qinghua
    Yang, Feibin
    Liu, Longzhong
    Li, Xuelong
    INFORMATION SCIENCES, 2015, 314 : 293 - 310
  • [46] Automatic segmentation of pulmonary parenchyma in thoracic CT and computer-aided diagnosis
    Department of Biomedical Engineering, South China University of Technology, Guangzhou 510640, China
    不详
    Huanan Ligong Daxue Xuebao/Journal of South China University of Technology (Natural Science), 2008, 36 (01): : 72 - 75
  • [47] Computer-Aided Diagnostic System for Detection of Hashimoto Thyroiditis on Ultrasound Images From a Polish Population
    Acharya, U. Rajendra
    Sree, S. Vinitha
    Krishnan, M. Muthu Rama
    Molinari, Filippo
    Zieleznik, Witold
    Bardales, Ricardo H.
    Witkowska, Agnieszka
    Suri, Jasjit S.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2014, 33 (02) : 245 - 253
  • [48] Hybrid lung segmentation in chest CT images for computer-aided diagnosis
    Yim, Y
    Hong, H
    Shin, YG
    Healthcom 2005: 7th International Workshop on Enterprise Networking and Computing in Healthcare Industry, Proceedings, 2005, : 378 - 383
  • [49] Accuracy of segmentation of a commercial computer-aided detection system for mammography
    Baker, JA
    Rosen, EL
    Crockett, MM
    Lo, JY
    RADIOLOGY, 2005, 235 (02) : 385 - 390
  • [50] A Computer-Aided Detection System for Automatic Mammography Mass Identification
    Samma, Hussein
    Lim, Chee Peng
    Samma, Ali
    NEURAL INFORMATION PROCESSING: MODELS AND APPLICATIONS, PT II, 2010, 6444 : 226 - 233