Automatic Fetal Segmentation Designed on Computer-Aided Detection with Ultrasound Images

被引:0
|
作者
Govindarajan, Mohana Priya [1 ]
Bharathi, Sangeetha Subramaniam Karuppaiya [1 ]
机构
[1] SRM Inst Sci & Technol, Dept Comp Sci & Engn, Chennai 600026, Tamil Nadu, India
来源
CMC-COMPUTERS MATERIALS & CONTINUA | 2024年 / 81卷 / 02期
关键词
Fetal growth; segmentation; ultrasound images; computer-aided detection; gestational age; crown-rump length; head circumference;
D O I
10.32604/cmc.2024.055536
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In the present research, we describe a computer-aided detection (CAD) method aimed at automatic fetal head circumference (HC) measurement in 2D ultrasonography pictures during all trimesters of pregnancy. The HC might be utilized toward determining gestational age and tracking fetal development. This automated approach is particularly valuable in low-resource settings where access to trained sonographers is limited. The CAD system is divided into two steps: to begin, Haar-like characteristics were extracted from ultrasound pictures in order to train a classifier using random forests to find the fetal skull. We identified the HC using dynamic programming, an elliptical fit, and a Hough transform. The computer-aided detection (CAD) program was well-trained on 999 pictures (HC18 challenge data source), and then verified on 335 photos from all trimesters in an independent test set. A skilled sonographer and an expert in medicine personally marked the test set. We used the crown-rump length (CRL) measurement to calculate the reference gestational age (GA). In the first, second, and third trimesters, the median difference between the standard GA and the GA calculated by the skilled sonographer stayed at 0.7 +/- 2.7, 0.0 +/- 4.5, and 2.0 +/- 12.0 days, respectively. The regular duration variance between the baseline GA and the health investigator's GA remained 1.5 +/- 3.0, 1.9 +/- 5.0, and 4.0 +/- 14 a couple of days. The mean variance between the standard GA and the CAD system's GA remained between 0.5 and 5.0, with an additional variation of 2.9 to 12.5 days. The outcomes reveal that the computer-aided detection (CAD) program outperforms an expert sonographer. When paired with the classifications reported in the literature, the provided system achieves results that are comparable or even better. We have assessed and scheduled this computerized approach for HC evaluation, which includes information from all trimesters of gestation.
引用
收藏
页码:2967 / 2986
页数:20
相关论文
共 50 条
  • [1] Computer-aided detection and segmentation of objects on medical images
    Belikova, T
    Palenichka, R
    Ivasenko, I
    WSCG'2002 SHORT COMMUNICATION PAPERS, CONFERENCE PROCEEDINGS, 2002, : 161 - 168
  • [2] Computer-aided thyroid nodule detection in ultrasound images
    Maroulis, DE
    Savelonas, MA
    Karkanis, SA
    Iakovidis, DK
    Dimitropoulos, N
    18TH IEEE SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, PROCEEDINGS, 2005, : 271 - 276
  • [3] COMPUTER-AIDED DENSITOMETRY OF ULTRASOUND IMAGES
    BAHAWAR, H
    KINDLER, M
    BERWING, K
    SCHLEPPER, M
    ZEITSCHRIFT FUR KARDIOLOGIE, 1986, 75 : 120 - 120
  • [4] A computer-aided method based on geometrical texture features for a precocious detection of fetal Hydrocephalus in ultrasound images
    Sahli, Hanene
    Ben Slama, Amine
    Mouelhi, Aymen
    Soayeh, Nesrine
    Rachdi, Radhouane
    Sayadi, Mounir
    TECHNOLOGY AND HEALTH CARE, 2020, 28 (06) : 643 - 664
  • [5] A Computer-Aided Method for Automatic Localization and Thickness Measurement of Peritoneum in Ultrasound Images
    Lin, Yu-Shan
    Lee, Tsung-Chun
    Chang, Hsuan T.
    Peng, Syu-Jyun
    Huang, Jenq-Wen
    Wang, Hsiu-Po
    Hung, Chung-Wen
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 8005 - 8008
  • [6] Computer-Aided System for Automatic Classification of Suspicious Lesions in Breast Ultrasound Images
    Karimi, Behnam
    Krzyzak, Adam
    ARTIFICIAL INTELLIGENCE AND SOFT COMPUTING, ICAISC 2014, PT II, 2014, 8468 : 131 - 142
  • [7] Computer-Aided Diagnosis System for Pancreatic Tumor Detection in Ultrasound Images
    Wu, C.
    Lin, M. H.
    Su, J. L.
    5TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2011 (BIOMED 2011), 2011, 35 : 627 - +
  • [8] COMPUTER-AIDED DETECTION OF DIFFUSE LIVER-DISEASE IN ULTRASOUND IMAGES
    ABE, C
    KAHN, CE
    DOI, K
    KATSURAGAWA, S
    INVESTIGATIVE RADIOLOGY, 1992, 27 (01) : 71 - 77
  • [9] COMPUTER-AIDED EVALUATION OF ULTRASOUND IMAGES OF THE THYROID
    HELD, P
    NICKEL, O
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1984, 141 (02): : 185 - 191
  • [10] Computer-Aided System for Breast Cancer Lesion Segmentation and Classification Using Ultrasound Images
    Salem, Saied
    Mostafa, Ahmed
    Ghalwash, Yasien E.
    Mahmoud, Manar N.
    Elnokrashy, Ahmed E.
    Mahmoud, Ahmed M.
    ADVANCES IN DIGITAL HEALTH AND MEDICAL BIOENGINEERING, VOL 3, EHB-2023, 2024, 111 : 297 - 305