Development of reinforced concrete column with replaceable plastic hinge based on metabolism concept

被引:1
|
作者
Uemura, Keita [1 ]
Hayashi, Manabu [2 ]
Nishine, Koki [3 ]
Takahashi, Yoshikazu [1 ]
机构
[1] Kyoto Univ, Dept Civil & Earth Resources Engn, Nishikyo Ku, Kyoto 6158540, Japan
[2] Muramoto Corp, Engn Dev Dept, Tennoji Ku, Osaka 5430002, Japan
[3] Muramoto Corp, Osaka Branch, Tennoji Ku, Osaka 5430002, Japan
关键词
Reinforced concrete; Column structure; Metabolism; Design for Disassembly; Seismic performance; Replacement; Repair; ROCKING BRIDGE PIERS; SEISMIC BEHAVIOR; RETROFIT; POLYMER;
D O I
10.1016/j.engstruct.2024.119007
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To update seismic performance and rapidly restore the transportation capacity of a bridge following an earthquake, this study introduces a new reinforced concrete (RC) column, termed "Metabolic RC column," which incorporates the Design for Disassembly and Metabolism Movement concepts. The proposed column features a plastic hinge comprising a permanent hinge and replaceable plastic zones. A Mesnager hinge is employed as the permanent hinge to resist the axial loads within the column cross section. In addition, cast-in-place RC members are used in replaceable plastic zones to dissipate the seismic energy. By replacing the plastic zone with an equivalent or superior alternative while the permanent hinge continues to carry the axial forces, the updating (i. e., metabolization) of the column seismic performance can be achieved without interrupting the daily operations of the structure. The feasibility of replacing plastic hinges while maintaining the resistance to axial loads was demonstrated through plastic zone replacement tests. Cyclic loading tests indicated that the maximum lateral load of the proposed Metabolic RC Column remained unchanged before and after the plastic zone replacement. The energy dissipated also remained nearly consistent before and after the plastic zone replacement. The largest reduction in dissipated energy at each displacement amplitude was approximately 6.7 % before and after replacement. Additionally, the cyclic loading tests emphasized the importance of minimizing damage to the permanent hinge and preventing the axial stiffness reduction to ensure maximum load capacity of the column after plastic zone replacement. Further, a numerical model was developed to replicate the load-displacement relationship of the specimens. The proposed model accurately calculated the maximum load of the specimen with an average error of approximately 3 % for each displacement amplitude and the dissipated energy with an error of approximately 6 %. The numerical analysis effectively captured the changes in the secondary stiffness of the columns before and after plastic zone replacement, attributing the differences in secondary stiffness to the reduced tensile forces exerted by the permanent hinge rebar.
引用
收藏
页数:23
相关论文
共 50 条
  • [31] Plastic hinge analysis for lightly reinforced and unconfined concrete structural walls
    Hoult, Ryan D.
    Goldsworthy, Helen M.
    Lumantarna, Elisa
    BULLETIN OF EARTHQUAKE ENGINEERING, 2018, 16 (10) : 4825 - 4860
  • [32] Calibration of the Length of the Plastic Hinge for Numerical Models of Reinforced Concrete Members
    Barbagallo, Francesca
    Bosco, Melina
    Floridia, Andrea
    Marino, Edoardo M.
    Panarelli, Dario
    Rossi, Pier Paolo
    Spinella, Nino
    BUILDINGS, 2022, 12 (10)
  • [33] Equivalent plastic hinge length of circular reinforced concrete bridge columns
    1600, Chinese Society of Civil Engineering (49):
  • [34] Probabilistic Approach for Estimating Plastic Hinge Length of Reinforced Concrete Columns
    Ning, Chao-Lie
    Li, Bing
    JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (03)
  • [35] Impact of Plastic Hinge Properties on Capacity Curve of Reinforced Concrete Bridges
    Shatarat, Nasim
    Shehadeh, Mutasem
    Naser, Mohammad
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2017, 2017
  • [36] Calculation Method of the Plastic Hinge Length for the Reinforced Concrete Frame Joint Based on Energy Dissipation
    Feng B.
    Xiong F.
    Chen J.
    Chen W.
    Gongcheng Kexue Yu Jishu/Advanced Engineering Sciences, 2018, 50 (05): : 77 - 86
  • [37] Experimental study on design quantity of stirrup plastic hinge region of concrete column
    Shao, Changjiang
    Wei, Wang
    Qi, Qiming
    Wang, Meng
    Hu, Chenxu
    Xiao, Zhenghao
    Xiao, Laichuan
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2019, 52 (12): : 114 - 123
  • [38] Simplified Design Procedure for Reinforced Concrete Columns Based on Equivalent Column Concept
    Afefy, Hamdy M.
    El-Tony, El-Tony M.
    INTERNATIONAL JOURNAL OF CONCRETE STRUCTURES AND MATERIALS, 2016, 10 (03) : 393 - 406
  • [39] Simplified Design Procedure for Reinforced Concrete Columns Based on Equivalent Column Concept
    Hamdy M. Afefy
    El-Tony M. El-Tony
    International Journal of Concrete Structures and Materials, 2016, 10 : 393 - 406
  • [40] Plastic Hinge Length for Flanged Reinforced Concrete Shear Walls with Asymmetric Sections
    Cai, Wen-Zhe
    Wang, Bin
    Shi, Qing-Xuan
    Wu, Meng-Zhen
    JOURNAL OF EARTHQUAKE ENGINEERING, 2024, 28 (10) : 2883 - 2908