Lithium Niobate Perovskite as the Support for Silver Nanoparticles for Non-Enzymatic Electrochemical Detection of Glucose

被引:0
|
作者
Pinon-Balderrama, Claudia Ivone [1 ,2 ]
Manriquez-Tristan, Atenea [3 ]
Maldonado-Orozco, Maria Cristina [3 ]
Hernandez-Escobar, Claudia Alejandra [2 ]
Reyes-Lopez, Simon Yobanny [4 ]
Espinosa-Cristobal, Leon Francisco [4 ]
Zaragoza-Contreras, Erasto Armando [2 ]
机构
[1] CONAHCYT CIMAV, Miguel Cervantes 120, Complejo Ind Chihuahua, Chihuahua 31136, Chihuahua, Mexico
[2] Ctr Invest Mat Avanzados, SC Miguel Cervantes 120,Complejo Ind, Chihuahua 31136, Chihuahua, Mexico
[3] Univ Autonoma Chihuahua, Fac Engn, Circuito Numeros 1 S-N,Nuevo Campus Univ,Nte 2, Chihuahua 31125, Chihuahua, Mexico
[4] Univ Autonoma Ciudad Juarez, Inst Biomed Sci, Envolvente PRONAF & Estocolmo S-N, Ciudad Juarez 32310, Chihuahua, Mexico
关键词
electrochemical sensor; glucose; homemade electrode; lithium niobate; perovskite; silver nanoparticles; ASCORBIC-ACID; SENSOR; ELECTRODE; NANOMATERIALS; COMPOSITE;
D O I
10.3390/chemosensors12100210
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Lithium niobate perovskite and silver nanoparticle-based nanocomposites (LNB:AgNPs) were explored for developing an electrochemical glucose sensor. The perovskite to silver nanoparticle ratios investigated were 4:1, 1:1, 1:2, 2:1, and 1:4. Among these, the 4:1 ratio, with the lowest silver content, demonstrated the most stable performance during glucose quantification via amperometry. The sensor's response was evaluated measuring the current at a fixed potential of 0.7 V following the injection of 1 mM glucose with each addition. The calibration curve obtained from the recorded data exhibited a linear response within the 1 to 15 mM glucose concentration range, achieving a sensitivity of 2 mu A/mM, a high correlation coefficient (R2 = 0.997), and a limit of detection (LOD) of 0.5 mu M. The LNB4:1AgNP composite allowed taking advantage of the unique properties of both components in a balanced manner, maximizing the sensor performance in practical applications.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] NON-ENZYMATIC ELECTROCHEMICAL GLUCOSE DETECTION
    TINDALL, CE
    MCMULLEN, JK
    MORROW, DJ
    IRISH JOURNAL OF MEDICAL SCIENCE, 1985, 154 (07) : 288 - 288
  • [2] A silver nanowire aerogel for non-enzymatic glucose detection
    Ma, Shichao
    Yuan, Xichen
    Yin, Xu
    Yang, Yang
    Ren, Li
    MICROCHEMICAL JOURNAL, 2023, 195
  • [3] High-performance non-enzymatic perovskite sensor for hydrogen peroxide and glucose electrochemical detection
    He, Juan
    Sunarso, Jaka
    Zhu, Yinlong
    Zhong, Yijun
    Miao, Jie
    Zhou, Wei
    Shao, Zongping
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 244 : 482 - 491
  • [4] Electrochemical Non-Enzymatic Detection of Glucose at Nanostructured Multilayer Electrode
    Maizelis, Antonina
    2019 IEEE 39TH INTERNATIONAL CONFERENCE ON ELECTRONICS AND NANOTECHNOLOGY (ELNANO), 2019, : 404 - 408
  • [5] Non-enzymatic electrochemical sensing of glucose
    Guangfeng Wang
    Xiuping He
    Lingling Wang
    Aixia Gu
    Yan Huang
    Bin Fang
    Baoyou Geng
    Xiaojun Zhang
    Microchimica Acta, 2013, 180 : 161 - 186
  • [6] Electrochemical non-enzymatic glucose sensors
    Park, S
    Boo, H
    Chung, TD
    ANALYTICA CHIMICA ACTA, 2006, 556 (01) : 46 - 57
  • [7] Non-enzymatic electrochemical sensing of glucose
    Wang, Guangfeng
    He, Xiuping
    Wang, Lingling
    Gu, Aixia
    Huang, Yan
    Fang, Bin
    Geng, Baoyou
    Zhang, Xiaojun
    MICROCHIMICA ACTA, 2013, 180 (3-4) : 161 - 186
  • [8] Non-Enzymatic Electrochemical Biosensing of Glucose Using Nanocomposites of Polyaniline Nanofibers and Silver
    Varghese, Eldhose V.
    Saidu, Femina Kanjirathamthadathil
    Schwandt, Carsten
    Thomas, George
    Joseph, Alex
    CHEMISTRYSELECT, 2022, 7 (01):
  • [9] Nanoporous cobalt oxide nanowires for non-enzymatic electrochemical glucose detection
    Kang, Luqi
    He, Daiping
    Bie, Lili
    Jiang, Ping
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 220 : 888 - 894
  • [10] Non-Enzymatic Electrochemical Detection of Glucose with a Gold Nanowire Array Electrode
    Zhao, Yue
    Chu, Jian
    Li, Shu-Hong
    Li, Wen-Wei
    Liu, Gang
    Tian, Yang-Chao
    Yu, Han-Qing
    ELECTROANALYSIS, 2014, 26 (03) : 656 - 663