Addressing Low-Cost Methane Sensor Calibration Shortcomings with Machine Learning

被引:0
|
作者
Kiplimo, Elijah [1 ]
Riddick, Stuart N. [1 ]
Mbua, Mercy [1 ]
Upreti, Aashish [1 ]
Anand, Abhinav [1 ]
Zimmerle, Daniel J. [1 ]
机构
[1] Colorado State Univ, Energy Inst, METEC, Ft Collins, CO 80523 USA
关键词
methane; quantification; metal-oxide; sensor; calibration; machine learning; WELL PADS; GAS; EMISSIONS; PERFORMANCE; OIL; QUANTIFICATION;
D O I
10.3390/atmos15111313
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Quantifying methane emissions is essential for meeting near-term climate goals and is typically carried out using methane concentrations measured downwind of the source. One major source of methane that is important to observe and promptly remediate is fugitive emissions from oil and gas production sites but installing methane sensors at the thousands of sites within a production basin is expensive. In recent years, relatively inexpensive metal oxide sensors have been used to measure methane concentrations at production sites. Current methods used to calibrate metal oxide sensors have been shown to have significant shortcomings, resulting in limited confidence in methane concentrations generated by these sensors. To address this, we investigate using machine learning (ML) to generate a model that converts metal oxide sensor output to methane mixing ratios. To generate test data, two metal oxide sensors, TGS2600 and TGS2611, were collocated with a trace methane analyzer downwind of controlled methane releases. Over the duration of the measurements, the trace gas analyzer's average methane mixing ratio was 2.40 ppm with a maximum of 147.6 ppm. The average calculated methane mixing ratios for the TGS2600 and TGS2611 using the ML algorithm were 2.42 ppm and 2.40 ppm, with maximum values of 117.5 ppm and 106.3 ppm, respectively. A comparison of histograms generated using the analyzer and metal oxide sensors mixing ratios shows overlap coefficients of 0.95 and 0.94 for the TGS2600 and TGS2611, respectively. Overall, our results showed there was a good agreement between the ML-derived metal oxide sensors' mixing ratios and those generated using the more accurate trace gas analyzer. This suggests that the response of lower-cost sensors calibrated using ML could be used to generate mixing ratios with precision and accuracy comparable to higher priced trace methane analyzers. This would improve confidence in low-cost sensors' response, reduce the cost of sensor deployment, and allow for timely and accurate tracking of methane emissions.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] An efficient catadioptric sensor calibration based on a low-cost test-pattern
    Ragot, N.
    Ertaud, J. Y.
    Savatier, X.
    Mazari, B.
    VISAPP 2006: PROCEEDINGS OF THE FIRST INTERNATIONAL CONFERENCE ON COMPUTER VISION THEORY AND APPLICATIONS, VOL 1, 2006, : 11 - +
  • [42] Modular Air Quality Calibration and Forecasting Method for Low-Cost Sensor Nodes
    Hashmy, Yousuf
    Khan, Zill Ullah
    Ilyas, Fahad
    Hafiz, Rehan
    Younis, Usman
    Tauqeer, Tauseef
    IEEE SENSORS JOURNAL, 2023, 23 (04) : 4193 - 4203
  • [43] Smart Multi-Sensor Calibration of Low-Cost Particulate Matter Monitors
    Villanueva, Edwin
    Espezua, Soledad
    Castelar, George
    Diaz, Kyara
    Ingaroca, Erick
    SENSORS, 2023, 23 (07)
  • [44] Design and Calibration of a Low-Cost SDI-12 Soil Moisture Sensor
    Gonzalez-Teruel, Juan D.
    Torres-Sanchez, Roque
    Blaya-Ros, Pedro J.
    Toledo-Moreo, Ana B.
    Jimenez-Buendia, Manuel
    Soto-Valles, Fulgencio
    SENSORS, 2019, 19 (03):
  • [45] Stochastic Online Calibration of Low-Cost Gas Sensor Networks With Mobile References
    Tancev, Georgi
    Toro, Federico Grasso
    IEEE ACCESS, 2022, 10 : 13901 - 13910
  • [46] A novel, low-cost, high performance dissolved methane sensor for aqueous environments
    Boulart, Cedric
    Mowlem, Matthew C.
    Connelly, Douglas P.
    Dutasta, Jean-Pierre
    German, Christopher R.
    OPTICS EXPRESS, 2008, 16 (17): : 12607 - 12617
  • [47] Performance of a low-cost methane sensor for ambient concentration measurements in preliminary studies
    Eugster, W.
    Kling, G. W.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2012, 5 (08) : 1925 - 1934
  • [48] Performance Analysis and Calibration of a New Low-Cost Capacitance Soil Moisture Sensor
    Kargas, George
    Soulis, Konstantinos X.
    JOURNAL OF IRRIGATION AND DRAINAGE ENGINEERING, 2012, 138 (07) : 632 - 641
  • [49] LOW-COST CALIBRATION OF ACOUSTIC LOCATORS
    不详
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1982, 71 (04): : 1040 - 1040
  • [50] Calibration of low-cost triaxial magnetometer
    Kuncar, Ales
    Sysel, Martin
    Urbanek, Tomas
    20TH INTERNATIONAL CONFERENCE ON CIRCUITS, SYSTEMS, COMMUNICATIONS AND COMPUTERS (CSCC 2016), 2016, 76