Cross-Domain Denoising for Low-Dose Multi-Frame Spiral Computed Tomography

被引:0
|
作者
Lu, Yucheng [1 ,2 ]
Xu, Zhixin [3 ]
Choi, Moon Hyung [4 ]
Kim, Jimin [4 ]
Jung, Seung-Won [3 ]
机构
[1] Korea Univ, Educ & Res Ctr Socialware IT, Seoul 02841, South Korea
[2] IT Univ Copenhagen, Dept Datal, DK-2300 Copenhagen, Denmark
[3] Korea Univ, Dept Elect Engn, Seoul 02841, South Korea
[4] Catholic Univ Korea, St Marys Hosp, Coll Med, Dept Radiol, Seoul 03083, South Korea
关键词
Image reconstruction; Noise reduction; Computed tomography; Noise; Image denoising; Optimization; Spirals; Deep learning; low-dose computed tomography; image and video denoising; CONVOLUTIONAL NEURAL-NETWORK; NOISE-REDUCTION; WAVELET-FRAME; CT; RECONSTRUCTION; ALGORITHM; EXPERTS;
D O I
10.1109/TMI.2024.3405024
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Computed tomography (CT) has been used worldwide as a non-invasive test to assist in diagnosis. However, the ionizing nature of X-ray exposure raises concerns about potential health risks such as cancer. The desire for lower radiation doses has driven researchers to improve reconstruction quality. Although previous studies on low-dose computed tomography (LDCT) denoising have demonstrated the effectiveness of learning-based methods, most were developed on the simulated data. However, the real-world scenario differs significantly from the simulation domain, especially when using the multi-slice spiral scanner geometry. This paper proposes a two-stage method for the commercially available multi-slice spiral CT scanners that better exploits the complete reconstruction pipeline for LDCT denoising across different domains. Our approach makes good use of the high redundancy of multi-slice projections and the volumetric reconstructions while leveraging the over-smoothing issue in conventional cascaded frameworks caused by aggressive denoising. The dedicated design also provides a more explicit interpretation of the data flow. Extensive experiments on various datasets showed that the proposed method could remove up to 70% of noise without compromised spatial resolution, while subjective evaluations by two experienced radiologists further supported its superior performance against state-of-the-art methods in clinical practice. Code is available at https://github.com/YCL92/TMD-LDCT.
引用
收藏
页码:3949 / 3963
页数:15
相关论文
共 50 条
  • [41] Low-dose computed tomography in pediatric radiology
    Salamipour, H
    Bramson, RT
    Anupindi, SA
    Gray, JE
    Hamberg, LM
    RADIOLOGY, 2001, 221 : 247 - 247
  • [42] Dosimetry for low-dose computed tomography of the chest
    Lenzen, H
    Roos, N
    Diederich, S
    Meier, N
    RADIOLOGE, 1996, 36 (06): : 483 - 488
  • [43] Noise Simulation for Low-dose Computed Tomography
    Fan, Yi
    Zamyatin, Alexander A.
    Nakanishi, Satoru
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3641 - 3643
  • [44] Low-dose Computed Tomography Screening in Japan
    Nawa, Takeshi
    Nakagawa, Tohru
    Mizoue, Tetsuya
    Endo, Katsuyuki
    JOURNAL OF THORACIC IMAGING, 2015, 30 (02) : 108 - 114
  • [45] Federated Condition Generalization on Low-dose CT Reconstruction via Cross-domain Learning
    Chen, Shixuan
    Cao, Boxuan
    Du, Yinda
    Zhang, Yaoduo
    He, Ji
    Bian, Zhaoying
    Zeng, Dong
    Ma, Jianhua
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION, MICCAI 2023, PT III, 2023, 14222 : 47 - 56
  • [46] Low-dose spiral computed tomography for measuring abdominal fat volume and distribution in a clinical setting
    Rogalla, P
    Meiri, N
    Hoksch, B
    Boeing, H
    Hamm, B
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 1998, 52 (08) : 597 - 602
  • [48] Low-dose spiral computed tomography for measuring abdominal fat volume and distribution in a clinical setting
    P Rogalla
    N Meiri
    B Hoksch
    H Boeing
    B Hamm
    European Journal of Clinical Nutrition, 1998, 52 : 597 - 602
  • [49] Dose Optimization for Computed Tomography Localizer Radiographs for Low-Dose Lung Computed Tomography Examinations
    Schmidt, Bernhard T.
    Hupfer, Martin
    Saltybaeva, Natalia
    Kolditz, Daniel
    Kalender, Willi A.
    INVESTIGATIVE RADIOLOGY, 2017, 52 (02) : 81 - 86
  • [50] Impact of Low-Dose Computed Tomography on Computed Tomography Orders and Scan Length
    Simmons, Curtis
    Milburn, James
    OCHSNER JOURNAL, 2019, 19 (04): : 303 - 308