Computed tomography (CT) has been used worldwide as a non-invasive test to assist in diagnosis. However, the ionizing nature of X-ray exposure raises concerns about potential health risks such as cancer. The desire for lower radiation doses has driven researchers to improve reconstruction quality. Although previous studies on low-dose computed tomography (LDCT) denoising have demonstrated the effectiveness of learning-based methods, most were developed on the simulated data. However, the real-world scenario differs significantly from the simulation domain, especially when using the multi-slice spiral scanner geometry. This paper proposes a two-stage method for the commercially available multi-slice spiral CT scanners that better exploits the complete reconstruction pipeline for LDCT denoising across different domains. Our approach makes good use of the high redundancy of multi-slice projections and the volumetric reconstructions while leveraging the over-smoothing issue in conventional cascaded frameworks caused by aggressive denoising. The dedicated design also provides a more explicit interpretation of the data flow. Extensive experiments on various datasets showed that the proposed method could remove up to 70% of noise without compromised spatial resolution, while subjective evaluations by two experienced radiologists further supported its superior performance against state-of-the-art methods in clinical practice. Code is available at https://github.com/YCL92/TMD-LDCT.
引用
收藏
页码:3949 / 3963
页数:15
相关论文
共 50 条
  • [1] Unsupervised Domain Adaptation for Low-Dose Computed Tomography Denoising
    Lee, Jaa-Yeon
    Kim, Wonjin
    Lee, Yebin
    Lee, Ji-Yeon
    Ko, Eunji
    Choi, Jang-Hwan
    IEEE ACCESS, 2022, 10 : 126580 - 126592
  • [2] A sinogram denoising algorithm for low-dose computed tomography
    Davood Karimi
    Pierre Deman
    Rabab Ward
    Nancy Ford
    BMC Medical Imaging, 16
  • [3] A sinogram denoising algorithm for low-dose computed tomography
    Karimi, Davood
    Deman, Pierre
    Ward, Rabab
    Ford, Nancy
    BMC MEDICAL IMAGING, 2016, 16
  • [4] Cross-Domain Low-Dose CT Image Denoising With Semantic Preservation and Noise Alignment
    Huang, Jiaxin
    Chen, Kecheng
    Ren, Yazhou
    Sun, Jiayu
    Pu, Xiaorong
    Zhu, Ce
    IEEE TRANSACTIONS ON MULTIMEDIA, 2024, 26 : 8771 - 8782
  • [5] Multi-scale perceptual modulation network for low-dose computed tomography denoising
    Huang, Jiexing
    Zhong, Anni
    Liu, Yujian
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (12) : 9290 - 9305
  • [6] Adaptive Image Denoising Approach for Low-Dose Computed Tomography
    Elyamani, Haneen A.
    El-Seoud, Samir A.
    Kudo, Hiroyuki
    Rashed, Essam A.
    2017 12TH INTERNATIONAL CONFERENCE ON COMPUTER ENGINEERING AND SYSTEMS (ICCES), 2017, : 66 - 72
  • [7] Lung cancer screening by low-dose spiral computed tomography
    van Klaveren, RJ
    Habbema, JDF
    Pedersen, JH
    de Koning, HJ
    Oudkerk, M
    Hoogsteden, HC
    EUROPEAN RESPIRATORY JOURNAL, 2001, 18 (05) : 857 - 866
  • [8] Screening for lung cancer with low-dose spiral computed tomography
    Jett, JR
    PROCEEDINGS OF THE 9TH CENTRAL EUROPEAN LUNG CANCER CONFERENCE, 2004, : 27 - 32
  • [9] Lung cancer screening with low-dose spiral computed tomography
    Stephenson, SM
    Mech, KF
    Sardi, A
    AMERICAN SURGEON, 2005, 71 (12) : 1015 - 1017
  • [10] Screening for lung cancer with low-dose spiral computed tomography
    Swensen, SJ
    Jett, JR
    Sloan, JA
    Midthun, DE
    Hartman, TE
    Sykes, AM
    Aughenbaugh, GL
    Zink, FE
    Hillman, SL
    Noetzel, GR
    Marks, RS
    Clayton, AC
    Pairolero, PC
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2002, 165 (04) : 508 - 513