TESTING AND DIAGNOSTIC OUT OF THE SERVICE POWER TRANSFORMER USING A SWEEP FREQUENCY RESPONSE ANALYSIS (SFRA) COMPARING WITH CHINA STANDARD

被引:0
|
作者
Djeriou S. [1 ,2 ]
Rouabhi R. [1 ]
Ayad I. [1 ]
Bouchahdane M. [3 ]
Dif M. [3 ]
机构
[1] Laboratory of Electrical Engineering LGE, University of M’sila
[2] Department of Electrical Engineering, Faculty of Technology, University of M’sila
[3] Institute of Electrical and Electronic Engineering, University M’hamed Bougara, Boumerdes
来源
Diagnostyka | 2024年 / 25卷 / 02期
关键词
diagnostics; power transformer; sweep frequency response analysis (SFRA);
D O I
10.29354/diag/185361
中图分类号
学科分类号
摘要
A several diagnostic methods used to evaluate and detect any potential issues or faults in the transformer before they cause significant problems. The research proposal focuses on employing the SFRA (Sweep Frequency Response Analysis) technique, renowned for its exceptional sensitivity and diagnostic capabilities. This method serves to identify the mechanical integrity of the transformer's core, winding distortion, and clamping structures by analyzing their electrical transfer functions across a broad frequency spectrum. By utilizing SFRA, the study aims to accurately predict the internal physical condition of the transformer, making it a highly effective and reliable indicator for assessing its overall health. The motivation of this present work is using all experiments of SFRA were conducted and validated on a three-phase 30kV/0.4KV voltage transformer with 50kVA at the laboratory of Msila university. The result of these experiments is presented and discussed in terms of interpretation the analyses based on different standards. © 2024 by the Authors.
引用
收藏
相关论文
共 50 条
  • [21] Diagnostic Methods of Frequency Response Analysis for Power Transformer Winding A Review
    Nnachi, G. U.
    Nicolae, D. V.
    2016 IEEE INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (PEMC), 2016, : 563 - 568
  • [22] Analysis Winding Deformation of Power Transformer Detection Using Sweep Frequency Impedance Technology
    Wang, Tao
    Hu, Yaqing
    Li, Xianfeng
    Zhang, Hua
    E, Zhenwei
    Zhang, Lei
    Bai, Zhongbin
    Guan, Chunmei
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT SYSTEMS AND INFORMATICS 2019, 2020, 1058 : 1009 - 1016
  • [23] Experimental Research of Vibration Sweep Frequency Response Analysis to Detect the Winding Deformation of Power Transformer
    Wang, F. H.
    Xu, J.
    Jin, Z. J.
    Gui, S. S.
    2010 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION: SMART SOLUTIONS FOR A CHANGING WORLD, 2010,
  • [24] Novel method for detection of transformer winding faults using Sweep Frequency Response Analysis
    Singh, Jashandeep
    Sood, Yog Raj
    Verma, Piush
    Jarial, Raj Kumar
    2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 2949 - +
  • [25] Sweep frequency response analysis method as a diagnostic tool to detect windings deformations in power transformers
    Ludwikowski, Karol
    PRZEGLAD ELEKTROTECHNICZNY, 2008, 84 (10): : 47 - 49
  • [26] Modelling Transfer Function of Power Transformers Using Sweep Frequency Response Analysis
    Jayaradma, K. L. I. M. Pramod B.
    Ediriweera, W. E. P. Sampath
    Lucas, J. R.
    Samarasinghe, R.
    2018 MORATUWA ENGINEERING RESEARCH CONFERENCE (MERCON) 4TH INTERNATIONAL MULTIDISCIPLINARY ENGINEERING RESEARCH CONFERENCE, 2018, : 500 - 505
  • [27] Sweep Frequency Response Analysis (SFRA) as a Diagnostic Tool To Detect Core & LV "V" Phase Winding Short and Core & HV "V" Phase Winding Short Faults which are Practically Simulated Separately on 10 KVA Power Transformer
    Pandya, Akshay A.
    Parekh, B. R.
    2014 RECENT ADVANCES AND INNOVATIONS IN ENGINEERING (ICRAIE), 2014,
  • [28] Assessment of Transformer Core and Winding Conditions for Distribution Transformers Using Sweep Frequency Response Analysis Waveforms
    Bohari, Z. H.
    Baharom, M. F.
    Sulaima, M. F.
    Jali, M. H.
    Jaafar, H. I.
    Jamri, M. S.
    INTERNATIONAL CONFERENCE ON MATHEMATICS, ENGINEERING AND INDUSTRIAL APPLICATIONS 2014 (ICOMEIA 2014), 2015, 1660
  • [29] Estimating Power Transformer High Frequency Model Parameters Using Frequency Response Analysis
    Abu-Siada, A.
    Mosaad, Mohamed I.
    Kim, Dowon
    El-Naggar, Mohamed F.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2020, 35 (03) : 1267 - 1277
  • [30] The detection of mechanical damage in power transformers using the Sweep Frequency Response Analysis method
    Locarno, M
    Tully, T
    Wilson, A
    NETA: TECHNICAL CONFERENCE PAPERS, 2001, : 23 - 31