A new DEM calibration method for wet and stick materials based on the BP neural network

被引:4
|
作者
Liu, Zhiyuan [1 ]
Yuan, Jianming [1 ,3 ]
Shen, Jiahe [1 ,2 ]
Hu, Yan [4 ]
Chen, Silong [4 ]
机构
[1] Wuhan Univ Technol, Sch Transportat & Logist Engn, Wuhan 430063, Peoples R China
[2] Univ Newcastle, TUNRA Bulk Solids TBS, Callaghan, NSW 2308, Australia
[3] Wuhan Univ Technol, Hainan Inst, Hainan 572019, Peoples R China
[4] CCCC First Harbor Engn CO LTD, Installat Engn Co LTD, Tianjin 300457, Peoples R China
关键词
WSMs; Modified AoR test; BP-NN; DEM calibrations; DISCRETE ELEMENT; FLOW CONDITIONS; PARAMETERS; REPOSE; ANGLE; SIMULATION; VERIFICATION; DRY;
D O I
10.1016/j.powtec.2024.120228
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The assessment of flow characteristics and the Discrete Element Method (DEM) calibrations for Wet and Sticky Materials (WSMs) are significantly demanded by the mining and transportation industries. However, the angle of repose (AoR), as a common DEM calibration method, has been facing challenges in adopting for WSMs. Due to the relatively high adhesion and cohesion of WSMs, it is difficult to form repeatable material heaps, resulting in inaccurate measurements of the AoRs. Therefore, this study aims to calibrate DEM parameters for WSMs under various conditions, utilizing a modified AoR test method and the Back Propagation-Neural Network (BP-NN). In the modified AoR test method, WSMs are discharged from a funnel using a screw feeder and fall closely against a vertical baffle to form a heap in a constrained direction. The new method combines the features of the traditional AoR test and the slump plane test to accurately measure the AoRs for different WSMs, including wet white sand, bulk coal, and corn powders. Test results are analysed to show the advantage of the modified AoR test. Furthermore, an innovative DEM calibration method based on the BP-NN is developed. By training the BP-NN with the database established according to the relationship between the measured and simulated AoRs, the DEM calibration parameters can be predicted rapidly for WSMs with different particle sizes and moisture contents. Validation is conducted for the wet white sand, from which the deviations and relative mean deviations between the experiment AoRs (Ae) A e ) and the calibration AoRs (Ac) A c ) are less than 2 degrees and degrees and 4 % respectively, indicating the capability of the developed method for WSMs DEM calibrations.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Method for vision system calibration based on neural network
    Zhang, Ai-Wu
    Sui, Zhen
    Hu, Shao-Xing
    Chen, Jian-Jun
    Li, Ming-Zhe
    Guangxue Jishu/Optical Technique, 2001, 27 (04): : 302 - 304
  • [32] New image reconstruction method for electrical impedance tomography based on BP neural network
    Hou, Weidong
    Mo, Yulong
    Guangxue Xuebao/Acta Optica Sinica, 2002, 22 (12): : 1475 - 1478
  • [33] Network Situation Assessment Method Based on Improved BP Neural Network
    Du, Zhiqiang
    Yao, Haitao
    Fu, Yanfang
    Cao, Zijian
    Liang, Hongtao
    Ren, Jinkang
    ELECTRONICS, 2023, 12 (03)
  • [34] Leakage Detection Method for Piping Network Based on BP Neural Network
    Jin Tao
    Zhou Ze-yuan
    MECHANICAL ENGINEERING, MATERIALS SCIENCE AND CIVIL ENGINEERING II, 2014, 470 : 738 - 742
  • [35] Calibration of a six-axis parallel manipulator based on BP neural network
    Zhang, Dianjin
    Zhang, Guangyu
    Li, Longqiu
    INDUSTRIAL ROBOT-THE INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH AND APPLICATION, 2019, 46 (05): : 692 - 698
  • [36] Display calibration model of cathode ray tube based on BP neural network
    Chen, Shuo
    Shen, Mo-Wei
    Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2007, 41 (06): : 901 - 904
  • [37] Parameter calibration method of clustered-particle logic concrete DEM model using BP neural network-particle swarm optimisation algorithm (BP-PSO) inversion method
    Pan, Xupeng
    Niu, Yanwei
    Zhao, Yu
    Huang, Pingming
    Wu, Yizhen
    ENGINEERING FRACTURE MECHANICS, 2023, 292
  • [38] RESEARCH ON BINOCULAR CAMERA CALIBRATION TECHNOLOGY BASED ON THE BP NEURAL NETWORK ALGORITHM
    Wang Hong-Jiang
    Zhao Ting-Ting
    Zhang Wen-Qiang
    Wang Nan
    FIFTH INTERNATIONAL CONFERENCE ON ADVANCED COMPUTER THEORY AND ENGINEERING (ICACTE 2012), 2012, : 135 - 142
  • [39] Background radiation compensation calibration method for film cooling infrared temperature measurement based on BP neural network
    Li, Yifan
    Liu, Cunliang
    Meng, Xianlong
    Fu, Song
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 159
  • [40] A Method for High Accuracy Heading Angle Combined with Ellipsoid Calibration and BP Neural Network
    Xie, XieWei
    Chen, Qiaoyuan
    Ming, Kun
    Wang, Chen
    Jin, Yufeng
    Shi, Guangyi
    2017 IEEE INTERNATIONAL CONFERENCE ON REAL-TIME COMPUTING AND ROBOTICS (RCAR), 2017, : 258 - 261