Performance investigation of a high-temperature absorption-compression heat transformer with liquid refrigerant injection

被引:1
|
作者
Zhou, Jiyuan [1 ,2 ,4 ]
Liu, Feng [1 ,4 ]
Gong, Yutong [1 ,3 ,4 ]
Sui, Jun [1 ,4 ]
机构
[1] Chinese Acad Sci, Inst Engn Thermophys, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] North China Elect Power Univ, Beijing 102206, Peoples R China
[4] Inst New Energy, Dongguan 523000, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
High-temperature heat transformer; High temperature lift; Absorption-compression; Refrigerant injection; Steam production; Exergy analysis; VAPOR COMPRESSION; EXERGY ANALYSIS; PUMP; ENERGY; SYSTEM;
D O I
10.1016/j.enconman.2024.119110
中图分类号
O414.1 [热力学];
学科分类号
摘要
The high-temperature heat pump technology is a promising approach to utilizing low-temperature waste heat while meeting industrial demands for high-temperature heat. However, existing high-temperature heat pump systems face challenges including insufficient temperature lift, system complexity, and rapid performance degradation at high output temperature. This paper proposes a novel, structurally simple high-temperature absorption-compression heat transformer, aiming to recover heat below 100 degrees C and achieve a large temperature lift above 70 degrees C. The system is analyzed from the aspects of energy, exergy, key parameters that impact its performance, and techno-economic comparison. Results show that injecting liquid refrigerant into the compressor chamber mitigates high superheat effects on the compressor, allowing for higher absorption pressure. The system achieves an output temperature of around 170 degrees C, with the compressor outlet temperature below 120 degrees C. Moreover, some liquid refrigerant evaporates by absorbing compressor superheat. This reduces power consumption of the compressor, heat input of the evaporator, and overall system exergy loss. Thus, the proposed system demonstrates improvements of 6.5 % and 7.5 % in coefficient of performance and exergy coefficient of performance, respectively. Besides, it is feasible to achieve absorption temperatures exceeding 170 degrees C by increasing the solution concentration or the pressure ratio, with the former being the more cost-effective approach. Furthermore, the specific costs of the proposed system are more than 20 % lower than those of other types of high-temperature heat pumps, demonstrating its superior economic feasibility.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Identification of Existing Challenges and Future Trends for the Utilization of Ammonia-Water Absorption-Compression Heat Pumps at High Temperature Operation
    Ahrens, Marcel Ulrich
    Loth, Maximilian
    Tolstorebrov, Ignat
    Hafner, Armin
    Kabelac, Stephan
    Wang, Ruzhu
    Eikevik, Trygve Magne
    APPLIED SCIENCES-BASEL, 2021, 11 (10):
  • [32] Experimental Performance Comparison of High-Glide Hydrocarbon and Synthetic Refrigerant Mixtures in a High-Temperature Heat Pump
    Brendel, Leon P. M.
    Bernal, Silvan N.
    Arpagaus, Cordin
    Roskosch, Dennis
    Bardow, Andre
    Bertsch, Stefan S.
    ENERGIES, 2024, 17 (08)
  • [33] High-glide refrigerant blends in high-temperature heat pumps: Part 1-Coefficient of performance
    Brendel, Leon P. M.
    Bernal, Silvan N.
    Widmaier, Philip
    Roskosch, Dennis
    Arpagaus, Cordin
    Bardow, Andre
    Bertsch, Stefan S.
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2024, 165 : 84 - 96
  • [34] Temperature stage matching and experimental investigation of high-temperature cascade heat pump with vapor injection
    Zou, Huiming
    Li, Xuan
    Tang, Mingsheng
    Wu, Jiang
    Tian, Changqing
    Butrymowicz, Dariusz
    Ma, Yongde
    Wang, Jin
    ENERGY, 2020, 212
  • [35] Investigation on the thermal performance of a high-temperature latent heat storage system
    Ma, Zhao
    Yang, Wei-Wei
    Yuan, Fan
    Jin, Bo
    He, Ya-Ling
    APPLIED THERMAL ENGINEERING, 2017, 122 : 579 - 592
  • [36] Effects of liquid refrigerant injection on the performance of a refrigeration system with an accumulator heat exchanger
    Kang, Hoon
    Lee, Sunil
    Kim, Yongchan
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (05): : 883 - 891
  • [37] A new absorption-compression refrigeration system using a mid-temperature heat source for freezing application
    Chen, Yi
    Han, Wei
    Sun, Liuli
    Jin, Hongguang
    CLEAN, EFFICIENT AND AFFORDABLE ENERGY FOR A SUSTAINABLE FUTURE, 2015, 75 : 560 - 565
  • [38] A novel compression-assisted double absorption energy storage heat transformer with high temperature lift
    Wang, Cun
    Bi, Yuehong
    ENERGY AND BUILDINGS, 2025, 330
  • [39] Performance of high-temperature absorption heat transformers using Alkitrate as the working pair
    Delft Univ of Technology, Delft, Netherlands
    Appl Therm Eng, 3 (255-262):
  • [40] Performance of high-temperature absorption heat transformers using Alkitrate as the working pair
    Zhuo, CZ
    Machielsen, CHM
    APPLIED THERMAL ENGINEERING, 1996, 16 (03) : 255 - 262