Electrical Performance and Degradation Analysis of Field-Aged PV Modules in Tropical Climates: A Comparative Experimental Study

被引:1
|
作者
Islam, Md. Imamul [1 ]
Bin Jadin, Mohd Shawal [1 ]
Al Mansur, Ahmed [2 ]
Alharbi, Talal [3 ]
机构
[1] Univ Malaysia Pahang Al Sultan Abdullah, Fac Elect & Elect Engn Technol, Pekan 26600, Pahang, Malaysia
[2] Green Univ Bangladesh, Dept Elect & Elect Engn, Dhaka 1460, Bangladesh
[3] Qassim Univ, Coll Engn, Dept Elect Engn, Qasim 52571, Saudi Arabia
关键词
Photovoltaic Modules; Aging Mechanism; PV Degradation; PV Electrical Characteristics; Tropical Climate; SDGs; SOLAR PHOTOVOLTAIC MODULES; SILICON; SI; TECHNOLOGIES; CRACKS;
D O I
10.1016/j.ecmx.2024.100719
中图分类号
O414.1 [热力学];
学科分类号
摘要
Performance degradation is a prevalent phenomenon in solar photovoltaic systems globally, with varying aging profiles and effects depending on environmental and climatic conditions. This paper presents an extensive investigation of the electrical performance, aging mechanisms, and degradation analysis of field-aged PV modules under the tropical climate of Malaysia. Utilizing a combination of visual inspection, I-V curve measurement, and thermal imaging techniques, this research provides a comprehensive assessment of the electrical and thermal properties of field-aged PV modules from two locations in Malaysia over extended periods (8 years at UMPSA and 10 years at Pasir Mas). The multi-faceted approach of the study allows for a deeper understanding of the degradation process, offering insights into the causes and effects of higher current and lower voltage in aged modules. The study found the average annual degradation rates at UMPSA were 0.3% for open circuit voltage (Voc), 0.23% for short circuit current (Isc), 0.81% for maximum power (Pmax), and 0.35% for fill factor (FF) and at Pasir Mas, the average annual degradation rates were 1.124% for Voc,-0.166% for Isc, 1.276% for Pmax, and 0.43% for FF. The study also found that monocrystalline silicon (m-Si) panels experienced an average power degradation of 6.48%, while polycrystalline silicon (p-Si) panels showed a higher degradation of 12.76%. However, Thermal imaging revealed significant temperature variations across the modules, with hotspots reaching up to 11.2 degrees C above cooler areas in UMPSA panels and an even more pronounced 26.1 degrees C difference in Pasir Mas modules. These temperature disparities highlight the uneven heat distribution and potential performance issues in the panels. This research contributes to the understanding of PV module degradation in tropical climates and aligns with sustainable development, climate change mitigation efforts, and SDG 7 by promoting sustainable energy solutions.
引用
收藏
页数:24
相关论文
共 50 条
  • [21] The Results of Performance Measurements of Field-aged Crystalline Silicon Photovoltaic Modules
    Skoczek, Artur
    Sample, Tony
    Dunlop, Ewan D.
    PROGRESS IN PHOTOVOLTAICS, 2009, 17 (04): : 227 - 240
  • [22] Comparative Performance Testing of Photovoltaic Modules in Tropical Climates of Indonesia
    Rosyid, Oo Abdul
    2ND PADJADJARAN INTERNATIONAL PHYSICS SYMPOSIUM 2015 (PIPS-2015): MATERIALS FUNCTIONALIZATION AND ENERGY CONSERVATIONS, 2016, 1712
  • [23] Analysis of the Long-Term Performance Degradation of Crystalline Silicon Photovoltaic Modules in Tropical Climates
    Luo, Wei
    Khoo, Yong Sheng
    Hacke, Peter
    Jordan, Dirk
    Zhao, Lu
    Ramakrishna, Seeram
    Aberle, Armin G.
    Reindl, Thomas
    IEEE JOURNAL OF PHOTOVOLTAICS, 2019, 9 (01): : 266 - 271
  • [24] Optical degradation of long-term, field-aged c-Si photovoltaic modules
    Parretta, A
    Bombace, M
    Graditi, G
    Schioppo, R
    SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2005, 86 (03) : 349 - 364
  • [25] Field Degradation and Failures of Aged Crystalline Silicon PV modules in Mexico
    Martinez Escobar, D.
    Sanchez-Perez, P. A.
    de la luz Santos Magdaleno, Rocio
    Ortega Cruz, Jose
    Tatapudi, Sai
    Sanchez Juarez, Aaron
    TamizhMani, GovindaSamy
    2017 IEEE 44TH PHOTOVOLTAIC SPECIALIST CONFERENCE (PVSC), 2017, : 1959 - 1964
  • [26] Investigation of the degradation and stabilization of EVA-based encapsulant in field-aged solar energy modules
    Klemchuk, P
    Ezrin, M
    Lavigne, G
    Holley, W
    Galica, J
    Agro, S
    POLYMER DEGRADATION AND STABILITY, 1997, 55 (03) : 347 - 365
  • [27] Comparative Reliability Analysis of PV Modules under tropical conditions
    Majumdar, Debasish
    Pal, Sudipta Basu
    Ganguly, Rajiv
    2021 INNOVATIONS IN ENERGY MANAGEMENT AND RENEWABLE RESOURCES(IEMRE 2021), 2021,
  • [28] Analysis and prediction of the performance and reliability of PV modules installed in harsh climates: Case study Iraq
    Hameed, Mohammed Adnan
    Kaaya, Ismail
    Al-Jbori, Mudhafar
    Matti, Qais
    Scheer, Roland
    Gottschalg, Ralph
    RENEWABLE ENERGY, 2024, 228
  • [29] Investigation of dominant degradation mode in field-aged photovoltaic modules using novel differential current-voltage analysis approach
    Meena, Roopmati
    Kumar, Manish
    Gupta, Rajesh
    PROGRESS IN PHOTOVOLTAICS, 2022, 30 (11): : 1312 - 1324
  • [30] Activation Energy for Solder Bond Degradation: Thermal Cycling of Field-aged Modules at Multiple Upper Temperatures
    Gopalakrishna, Hamsini
    Sinha, Archana
    Jordan, Dirk
    Tamizhmani, Govindasamy
    2019 IEEE 46TH PHOTOVOLTAIC SPECIALISTS CONFERENCE (PVSC), 2019, : 1955 - 1960