Direct Transient Stability Assessment of Grid-Connected Voltage Source Converters: A Transient Energy Functions Perspective

被引:0
|
作者
Poulose, Albert [1 ]
Kim, Soobae [1 ]
机构
[1] Kyungpook Natl Univ, Sch Elect & Elect Engn, Dept Elect Engn, Daegu 41566, South Korea
来源
IEEE ACCESS | 2024年 / 12卷
关键词
Power system stability; Transient analysis; Stability criteria; Numerical stability; Grid forming; Grid following; Voltage control; Lyapunov methods; Renewable energy sources; Direct transient stability; grid-forming; grid-following; Lyapunov functions; power system stability; transient stability; transient energy functions; renewable penetrated systems; voltage source converters; VIRTUAL SYNCHRONOUS GENERATORS; POWER-SYSTEMS; SYNCHRONIZATION;
D O I
10.1109/ACCESS.2024.3450316
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The integration of renewable energy sources ( RES ) into the grid predominantly utilizes voltage source converters ( VSC ) with a grid-following ( GFL ) connection strategy. This approach, however, often faces instability issues in low-inertia grid regions. To enhance grid resilience in renewable-dominated power systems, grid-forming ( GFM ) connection strategies have been introduced, with the virtual synchronous machine ( VSM ) technique based on GFM control being particularly prevalent. Consequently, transient stability investigations of power systems employing both GFL and GFM connection techniques have gained increasing relevance. This paper proposes an innovative fast direct transient stability analysis ( DTSA ) approach that leverages Lyapunov's direct method to assess the transient stability of a GFM with VSM control technique, incorporating the influence of parallel-connected VSC with GFL control strategy. The proposed DTSA approach models the GFL as a current source with parallel internal reactance and the GFM as a voltage source with series internal reactance. Detailed analytical derivations of the DTSA approach using transient energy functions, along with the DTSA criterion for the interconnected system, are presented to determine the critical clearing time ( CCT ) of the GFM-employed VSC. . Furthermore, Matlab/Simulinkbased electromagnetic transient ( EMT ) time-domain ( t - d) ) simulation responses are utilized to validate the accuracy and computational effectiveness of the proposed fast DTSA approach. In addition, the proposed DTSA approach offers considerable benefits for efficiently assessing and managing power systems that heavily rely on RES in terms of operational planning and contingency management.
引用
收藏
页码:133545 / 133556
页数:12
相关论文
共 50 条
  • [31] Optimal Model Predictive Controller for Grid-Connected Voltage Source Converters
    Mardani, Mohammad Mehdi
    Mijatovic, Nenad
    Dragicevic, Tomislav
    2022 IEEE 31ST INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2022, : 7 - 11
  • [32] Unified Impedance Model of Grid-Connected Voltage-Source Converters
    Wang, Xiongfei
    Harnefors, Lennart
    Blaabjerg, Frede
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (02) : 1775 - 1787
  • [33] A Model Predictive Resonant Controller for Grid-Connected Voltage Source Converters
    Yoo, Dae Keun
    Wang, Liuping
    IECON 2011: 37TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2011,
  • [34] A simulation method of grid-connected wind farm on transient stability
    Han, Xiaoning
    Lei, Qiaohong
    Shi, Yan
    Han, Xiaoqing
    2007 CONFERENCE PROCEEDINGS IPEC, VOLS 1-3, 2007, : 955 - +
  • [35] Nonlinear current control strategy for grid-connected voltage source converters
    Sgro, Domenico
    Correia, Wilkley Bezerra
    Leao, Ruth Pastora Saraiva
    Tofoli, Fernando Lessa
    Tiburcio, Silas Alysson Souza
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 142
  • [36] Application of Control Lyapunov Functions to voltage source converters-based high voltage direct current for improving transient stability
    Latorre, H. F.
    Ghandhari, M.
    Soder, L.
    2007 IEEE LAUSANNE POWERTECH, VOLS 1-5, 2007, : 244 - 249
  • [37] Transient Angle Stability Analysis of Grid-Connected Converters with the First-order Active Power Loop
    Wu, Heng
    Wang, Xiongfei
    THIRTY-THIRD ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2018), 2018, : 3011 - 3016
  • [38] Design-Oriented Transient Stability Analysis of Grid-Connected Converters: A Comparative Study of Analysis Methods
    Liu, Chao Charles
    Tse, Chi K.
    Huang, Meng
    Wu, Zhenxi
    Han, Hua
    Yang, Jingxi
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2025, 40 (01) : 749 - 763
  • [39] Application of SFCL to Improve the Transient Voltage Stability of Grid-Connected Wind Farm with DFIG during Grid Faults
    Ou, Ran
    Xiao, Xian Yong
    Zou, Zhi Ce
    Li, Chang Song
    Wu, Dan Yue
    2015 IEEE International Conference on Applied Superconductivity and Electromagnetic Devices (ASEMD), 2015, : 240 - 241
  • [40] Dominant Transient Unstable Characteristics of PLL-based Grid-connected Converters
    Zhang Y.
    Zhan M.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2023, 43 (23): : 9285 - 9296