Simulation analysis and experimental research on static performance of water-hydraulic pressure difference control valve

被引:0
|
作者
Yang, Yong [1 ]
Zhang, Zengmeng [1 ,2 ]
Jia, Yunrui [1 ]
Geng, Tingyu [1 ]
Xu, Weiling [1 ]
Zhang, Kang [1 ,3 ]
机构
[1] Dalian Maritime Univ, Coll Naval Architecture & Ocean Engn, Dalian, Peoples R China
[2] Dalian Maritime Univ, Liaoning Prov Key Lab Rescue & Salvage Engn, Dalian, Peoples R China
[3] Dalian Maritime Univ, Int Joint Res Ctr Subsea Engn Technol & Equipment, Dalian, Peoples R China
基金
中国国家自然科学基金;
关键词
Pressure difference control; Water-hydraulic system; Control valve; CFD; Experimental research; FLOW FORCES; SEAT VALVE; ACTUATOR;
D O I
10.1016/j.flowmeasinst.2024.102723
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Many hydraulic tools, like hydraulic cylinders and hydraulic artificial muscle joints are operated by adjusting pressure differences between different zones. Typically, the method employed to change the pressure difference is establishing hydraulic bridges and adjusting liquid resistance. While effective, this method's drawback is complex structures. To address this issue, a water-hydraulic pressure difference control valve, integrating two hydraulic bridges, was designed. The static performances including the output pressure difference, the flow rate and the force acting on the valve core were analyzed using AMESim and computational fluid dynamics simulations. Based on the simulation results, a prototype of voice coil motor direct drive pressure difference control valve was manufactured and the corresponding experiments were carried out. The computational fluid dynamics simulation results show that the internal leakage and the through-flow capacity difference between throttling grooves affect the flow field characteristics of the valve. When the pump pressure is 3 MPa and the valve opening is at the middle position, the internal leakage increases the flow rate from 2.25 L/min to 2.38 L/min, and the through-flow capacity difference reduces the control port pressure from the theoretical analysis of 1.5 MPa-1.41 MPa. Furthermore, combined with the analysis of the external liquid resistance, the AMESim model of the pressure difference control valve is modified. When the pump pressure is 3 MPa, the pressure difference and flow rate average deviations between the modified AMESim model and the experiment are 0.021 MPa and 0.048 L/ min. Finally, a rotational angle experiment for a water hydraulic artificial muscle joints showed satisfactory control effects, suggesting the valve's application in controlling hydraulic tools and actuators.
引用
收藏
页数:20
相关论文
共 50 条
  • [41] Experimental validation of the lifetime performance of a proportional 4/3 hydraulic valve operating in water
    Majdic, F.
    Pezdirnik, J.
    Kalin, M.
    TRIBOLOGY INTERNATIONAL, 2011, 44 (12) : 2013 - 2021
  • [42] Design and Analysis of Slide Valve Used in Water Hydraulic Servo Valve Based on Flow Field Simulation
    Wang Xinhua
    Zheng Jian
    Li Wei
    Sun Shuwen
    MECHANICAL ENGINEERING AND GREEN MANUFACTURING, PTS 1 AND 2, 2010, : 1279 - 1283
  • [43] Research on Chilled Water Pressure Difference of the Model Reference Adaptive Control
    Jiang, Hongmei
    Cai, Dongdong
    Nian, Yugui
    Ren, Qingchang
    PROCEEDINGS OF 2013 CHINESE INTELLIGENT AUTOMATION CONFERENCE: INTELLIGENT AUTOMATION, 2013, 254 : 531 - 539
  • [44] Hydraulic Pressure Control System Simulation and Performance Test of Lower Extremity Exoskeleton
    Li, Xingxing
    Guo, Qing
    Zhang, Lulu
    Zhou, Hong
    Zhang, Xianggang
    ADVANCED MANUFACTURING TECHNOLOGY, PTS 1-4, 2012, 472-475 : 2548 - +
  • [45] An experimental research and analysis of control valve in variable displacement compressor
    Chang, D.
    Dou, C.
    Hu, S.
    Jiang, Y.
    Qiche Gongcheng/Automotive Engineering, 2001, 23 (01): : 37 - 40
  • [46] Experimental research on the dynamic instability and water hammer effect of pressure relief valve
    Ma W.
    Pan T.
    International Journal of Fluid Machinery and Systems, 2020, 13 (01) : 150 - 159
  • [47] Optimal Design and Experimental Research of the Anti-Cavitation Structure in the Water Hydraulic Relief Valve
    Xu, He
    Wang, Haihang
    Hu, Mingyu
    Jiao, Liye
    Li, Chang
    JOURNAL OF PRESSURE VESSEL TECHNOLOGY-TRANSACTIONS OF THE ASME, 2018, 140 (05):
  • [48] Characteristic analysis of a water hydraulic pilot-operated pressure-reducing valve
    Mao, Xuyao
    Hu, Junhua
    Wu, Chao
    Liu, Yiou
    Liu, Yinshui
    3RD INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY, ENVIRONMENT AND CHEMICAL ENGINEERING, 2017, 69
  • [49] Investigation on the Dynamic Characteristics of a New High-Pressure Water Hydraulic Flow Control Valve
    Liu, Wenchao
    Tian, Jie
    Wang, Hongyao
    Li, Junshi
    Zhou, Rulin
    Cao, Yu
    MACHINES, 2024, 12 (09)
  • [50] Phenomenon of labyrinth weal with Low static pressure difference and large clearancePrediction of performance and experimental result
    K. Shimada
    K. Kimura
    H. Ohta
    K. Aoki
    Journal of Visualization, 2003, 6 : 395 - 405