Simulation analysis and experimental research on static performance of water-hydraulic pressure difference control valve

被引:0
|
作者
Yang, Yong [1 ]
Zhang, Zengmeng [1 ,2 ]
Jia, Yunrui [1 ]
Geng, Tingyu [1 ]
Xu, Weiling [1 ]
Zhang, Kang [1 ,3 ]
机构
[1] Dalian Maritime Univ, Coll Naval Architecture & Ocean Engn, Dalian, Peoples R China
[2] Dalian Maritime Univ, Liaoning Prov Key Lab Rescue & Salvage Engn, Dalian, Peoples R China
[3] Dalian Maritime Univ, Int Joint Res Ctr Subsea Engn Technol & Equipment, Dalian, Peoples R China
基金
中国国家自然科学基金;
关键词
Pressure difference control; Water-hydraulic system; Control valve; CFD; Experimental research; FLOW FORCES; SEAT VALVE; ACTUATOR;
D O I
10.1016/j.flowmeasinst.2024.102723
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Many hydraulic tools, like hydraulic cylinders and hydraulic artificial muscle joints are operated by adjusting pressure differences between different zones. Typically, the method employed to change the pressure difference is establishing hydraulic bridges and adjusting liquid resistance. While effective, this method's drawback is complex structures. To address this issue, a water-hydraulic pressure difference control valve, integrating two hydraulic bridges, was designed. The static performances including the output pressure difference, the flow rate and the force acting on the valve core were analyzed using AMESim and computational fluid dynamics simulations. Based on the simulation results, a prototype of voice coil motor direct drive pressure difference control valve was manufactured and the corresponding experiments were carried out. The computational fluid dynamics simulation results show that the internal leakage and the through-flow capacity difference between throttling grooves affect the flow field characteristics of the valve. When the pump pressure is 3 MPa and the valve opening is at the middle position, the internal leakage increases the flow rate from 2.25 L/min to 2.38 L/min, and the through-flow capacity difference reduces the control port pressure from the theoretical analysis of 1.5 MPa-1.41 MPa. Furthermore, combined with the analysis of the external liquid resistance, the AMESim model of the pressure difference control valve is modified. When the pump pressure is 3 MPa, the pressure difference and flow rate average deviations between the modified AMESim model and the experiment are 0.021 MPa and 0.048 L/ min. Finally, a rotational angle experiment for a water hydraulic artificial muscle joints showed satisfactory control effects, suggesting the valve's application in controlling hydraulic tools and actuators.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] EXPERIMENTAL STUDY ON PRESSURE TRANSIENTS WITH CAVITATION IN LOW PRESSURE WATER-HYDRAULIC PIPELINE
    Jiang, Dan
    Ren, Cong
    Guo, Qing
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER MEETING, 2018, VOL 2, 2018,
  • [2] Simulation and experiment on static characteristic of water hydraulic proportional pressure relief valve
    Zhang, Zeng-Meng
    Zhou, Hua
    Gao, Yuan-An
    Chen, Ying-Long
    Meitan Xuebao/Journal of the China Coal Society, 2009, 34 (11): : 1569 - 1573
  • [3] Simulation analysis and experimental research on mechanical properties of water hydraulic ball poppet valve
    Yang, Yong
    Zhang, Zeng-Meng
    Chen, Ying-Long
    Gong, Yong-Jun
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2023, 45 (01)
  • [4] Simulation analysis and experimental research on mechanical properties of water hydraulic ball poppet valve
    Yong Yang
    Zeng-Meng Zhang
    Ying-Long Chen
    Yong-Jun Gong
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2023, 45
  • [5] Research on control characteristic and compensation of water hydraulic proportional pressure relief valve
    Zhang Z.-M.
    Zhou H.
    Chen Y.-L.
    Gao Y.-A.
    Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2010, 44 (11): : 2093 - 2099
  • [6] Theoretical and Experimental Research on a Pressure-Reducing Valve for a Water Hydraulic Vane Pump
    Luo, Liang
    He, Xiaofeng
    Den, Ben
    Huang, Xing
    JOURNAL OF PRESSURE VESSEL TECHNOLOGY-TRANSACTIONS OF THE ASME, 2014, 136 (02):
  • [7] Static experimental research on a water hydraulic trial system
    Tang, XY
    Lin, XQ
    Yuan, ZR
    Proceedings of the Sixth International Conference on Fluid Power Transmission and Control, 2005, : 199 - 203
  • [8] Theoretical and Experimental Research on a Three-Way Water Hydraulic Pressure Reducing Valve
    He, Xiaofeng
    Zhao, Daoxin
    Sun, Xiao
    Zhu, Bihai
    JOURNAL OF PRESSURE VESSEL TECHNOLOGY-TRANSACTIONS OF THE ASME, 2017, 139 (04):
  • [9] Simulation and experimental research of hydraulic pressure and intake valve lift on a fully hydraulic variable valve system for a spark-ignition engine
    Chen, Fei
    Chang, Yingjie
    Xie, Zongfa
    Zhang, Kaiyu
    Sun, Tingting
    Li, Xiaorui
    Huang, Yuzhen
    ADVANCES IN MECHANICAL ENGINEERING, 2018, 10 (05):
  • [10] Simulation and experimental study of pilot operated water hydraulic pressure relief valve with diaphragm seal
    Zhu, Bihai
    He, Wei
    He, Xiaofeng
    Liu, Yinshui
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2012, 48 (02): : 179 - 185