Determination of Column Efficiency of True Boiling Point Distillation Apparatus by Gas Chromatography

被引:0
|
作者
Wang, Xin [1 ]
Fan, Dengli [1 ]
Wang, Xiaowei [1 ]
Zhang, Yiwei [1 ]
Zhang, Qundan [1 ]
机构
[1] SINOPEC Research Institute of Petroleum Processing Co.,Ltd., Beijing,100083, China
来源
Shiyou Xuebao, Shiyou Jiagong/Acta Petrolei Sinica (Petroleum Processing Section) | 2024年 / 40卷 / 03期
关键词
Aromatic hydrocarbons - Boiling point - Column chromatography - Efficiency - Gas chromatography - Heptane;
D O I
10.3969/j.issn.1001-8719.2024.03.027
中图分类号
学科分类号
摘要
The good separation performance of the true boiling point (TBP)distilation apparatus is the key to ensuring the accuracy and reliability of crude oil evaluation data. However, the current refractive index (RI) method for measurement of the column efficiency faces problems such as complicated process and vulnerability to aromatic interference.To improve the measurement efficiencyand accuracy, this paper studies the feasibility of gas chromatography (GC) method to evaluate the column efficiency of TBP distilation apparatus.Comparative analysis shows that the theoretical plate number measured by GC is lowered by 1 as compared with that measured by RI. The relative deviation of n-heptane mole fraction measured by GC and RI method is within ±3%. GC can effectively eliminate the impact of aromatic hydrocarbons on the system, and meets the need for long-term stable monitoring of column efficiency. © 2024 Editorial Office of Acta Petrolei Sinica. All rights reserved.
引用
收藏
页码:820 / 826
相关论文
共 50 条
  • [31] RETENTION TEMPERATURE AND COLUMN EFFICIENCY IN PROGRAMMED TEMPERATURE GAS CHROMATOGRAPHY
    HABGOOD, HW
    HARRIS, WE
    ANALYTICAL CHEMISTRY, 1960, 32 (04) : 450 - 453
  • [32] Dependence of the efficiency of a capillary column in gas chromatography on the relative pressure of the carrier gas
    A. A. Korolev
    V. E. Shiryaeva
    T. P. Popova
    A. A. Kurganov
    Journal of Analytical Chemistry, 2011, 66 : 184 - 188
  • [33] Dependence of the efficiency of a capillary column in gas chromatography on the relative pressure of the carrier gas
    Korolev, A. A.
    Shiryaeva, V. E.
    Popova, T. P.
    Kurganov, A. A.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 66 (02) : 184 - 188
  • [34] Application of dividing wall column in azeotropic distillation with intermediate boiling-point heteroazeotrope: Simulation and optimization
    Wang, Mingmei
    Song, Erwei
    Li, Lin
    Zhang, Yaochang
    Wang, Erqiang
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2023, 189 : 384 - 400
  • [35] METHODS AND EXAMPLES FOR THE DETERMINATION OF EFFICIENCY FACTORS OF INDUSTRIAL COLUMN PLATES FOR FRACTIONAL DISTILLATION
    SCHOBER, G
    CHEMISCHE TECHNIK, 1982, 34 (04): : 183 - 186
  • [36] DETERMINATION OF VOLATILES IN SOLIDS AND HIGH-BOILING LIQUIDS BY GAS CHROMATOGRAPHY
    RICE, DD
    TROWELL, JM
    ANALYTICAL CHEMISTRY, 1967, 39 (02) : 157 - &
  • [37] DETERMINATION OF CYCLOPENTOLATE BY CAPILLARY COLUMN GAS-LIQUID-CHROMATOGRAPHY
    ANDERMANN, G
    RICHARD, A
    JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1984, 7 (03): : 144 - 146
  • [38] Headspace gas chromatography with capillary column for urine alcohol determination
    Corrêa, CL
    Pedroso, RC
    JOURNAL OF CHROMATOGRAPHY B, 1997, 704 (1-2): : 365 - 368
  • [39] Do the True Boiling-Point Distillation Yields of Crude Oil Blends Obey the Additive Blending Rule?
    Stratiev, Dicho
    Shishkova, Ivelina
    Dinkov, Rosen
    Sotirov, Sotir
    Sotirova, Evdokia
    Atanassov, Krassimir
    Ribagin, Simeon
    Nikolova, Radoslava
    Veli, Anife
    Palichev, Georgi
    Stratiev, Danail D.
    PROCESSES, 2023, 11 (07)
  • [40] DETERMINATION OF MELISSYL ALCOHOL BY CAPILLARY COLUMN GAS-CHROMATOGRAPHY
    LIU, G
    XIN, Z
    CHROMATOGRAPHIA, 1990, 30 (5-6) : 267 - 270