Development of a closed-loop controller for functional electrical stimulation therapy plus visual feedback balance training for standing balance training

被引:0
|
作者
Lee, Jae W. [1 ,2 ]
Grabke, Emerson [1 ,2 ]
Chow, Kelvin [1 ,2 ]
Musselman, Kristin E. [2 ,3 ,4 ]
Masani, Kei [1 ,2 ]
机构
[1] Univ Toronto, Inst Biomed Engn, 164 Coll St, Toronto, ON M5S 3G9, Canada
[2] Univ Hlth Network, Toronto Rehabil Inst, KITE, 520 Sutherland Dr, Toronto, ON M4G 3V9, Canada
[3] Univ Toronto, Temerty Fac Med, Dept Phys Therapy, 500 Univ Ave, Toronto, ON M5G 1V7, Canada
[4] Univ Toronto, Rehabil Sci Inst, Temerty Fac Med, 500 Univ Ave, Toronto, ON M5G 1V7, Canada
关键词
Balance training; Visual feedback training; Functional electrical stimulation; Neurorehabilitation; Spinal cord injury; ANKLE STIFFNESS; QUIET; STABILITY; TORQUE;
D O I
10.1016/j.medengphy.2024.104238
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Individuals with incomplete spinal cord injury (iSCI) demonstrate impaired upright balance, resulting in increased fall risk. Task-specific visual feedback balance training (VFBT) has previously been shown to improve upright balance. In addition, therapies using functional electrical stimulation (FES) have been shown to improve various motor functions. Combining VFBT with FES therapy (FES+VFBT) may synergistically improve balance control for those with iSCI. Here we developed the FES+VFBT system that delivered physiologically relevant electrical stimulations to soleus (SOL) and tibialis anterior (TA) muscles during VFBT. Ten young able-bodied individuals participated. Kinematic, kinetic, SOL and TA electromyography (EMG) data during quiet standing and limits-of-stability test were used to design the controller for the FES+VFBT system. To evaluate the performance of the designed controller, the controller outputs, which represented stimulation intensities, were compared with the recorded SOL and TA EMG during the four tasks associated with VFBT (i.e., bullseye, hunting, colour-matching, and ellipse tasks). Except for the bullseye task, the designed controller outputs were highly correlated with the recorded EMG, suggesting that the controller could generate electrical stimulations in a physiological manner. We expect that the addition of FES therapy to VFBT could contribute to improving standing balance for individuals with iSCI.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Perspectives of individuals with chronic spinal cord injury following novel balance training involving functional electrical stimulation with visual feedback: a qualitative exploratory study
    Houston, David J.
    Unger, Janelle
    Lee, Jae W.
    Masani, Kei
    Musselman, Kristin E.
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2021, 18 (01)
  • [22] The Effects of Functional Electrical Stimulation on Balance of Stroke Patients in the Standing Posture
    Kim, Mee-Young
    Kim, Ju-Hyun
    Lee, Jeong-Uk
    Yoon, Na-Mi
    Kim, Bokyung
    Kim, Junghwan
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2012, 24 (01) : 77 - 81
  • [23] Paraplegia: Prolonged standing using closed-loop functional electrical stimulation and Andrews ankle-foot orthosis
    Davis, R
    Houdayer, T
    Andrews, B
    Barriskill, A
    ARTIFICIAL ORGANS, 1999, 23 (05) : 418 - 420
  • [24] Mechanomyography based closed-loop Functional Electrical Stimulation cycling system
    Woods, Billy
    Subramanian, Mahendran
    Shafti, Ali
    Faisal, A. Aldo
    2018 7TH IEEE INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB2018), 2018, : 179 - 184
  • [25] A closed-loop electrical stimulation system triggered by EOG for acupuncture therapy
    Yuan, Ding
    Li, Yurong
    Wang, Tian
    Chen, Jianguo
    Chen, Dongyi
    Lin, Dong
    Yang, Yuan
    SYSTEMS SCIENCE & CONTROL ENGINEERING, 2020, 8 (01) : 128 - 140
  • [26] Combined effects of functional task training with electrical stimulation on motor abilities and balance in children with diplegia
    Randa A. Mousa
    Eman E. Elhadidy
    Walaa M. Ali
    Bulletin of Faculty of Physical Therapy, 29 (1)
  • [27] Development and Validation of a Closed-Loop Functional Electrical Stimulation-Based Controller for Gait Rehabilitation Using a Finite State Machine Model
    Hayami, Naoki
    Williams, Heather E.
    Shibagaki, Koshi
    Vette, Albert H.
    Suzuki, Yasuyuki
    Nakazawa, Kimitaka
    Nomura, Taishin
    Milosevic, Matija
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2022, 30 : 1642 - 1651
  • [28] Dynamic balance training with sensory electrical stimulation in chronic stroke patients
    Worms, Georg
    Matjacic, Zlatko
    Gollee, Henrik
    Cikajlo, Imre
    Goljar, Nika
    Hunt, Kenneth J.
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 4458 - +
  • [29] EARLY INPATIENT TRAINING WITH REGYS-I COMPUTERIZED CLOSED-LOOP ELECTRICAL-STIMULATION BICYCLE ERGOMETRY
    SIPSKI, ML
    SCHWEER, SA
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1988, 69 (09): : 764 - 764
  • [30] Development Of A Visual Anticipatory Training And Balance Evaluation System For Elderly
    Chen, Po-Jung
    Wei, Shun-Hwa
    Sung, Wen-Hsu
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 : 399 - 399