Developing a method for calculating the mean outdoor radiant temperature for thermal stress in Guangzhou

被引:1
|
作者
Zhou, Xiaoqing [1 ]
Tang, Tianwei [1 ]
Feng, Xiwen [1 ]
Gao, Naiping [2 ]
Yang, Yanping [1 ]
Fang, Zhaosong [1 ]
机构
[1] Guangzhou Univ, Sch Civil Engn & Transportat, Guangzhou 510006, Peoples R China
[2] Tongji Univ, Sch Mech Engn, Shanghai 200092, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
mean radiant temperature; outdoor thermal environment; solar radiation; ground-cover surface; six-direction integral method; GLOBAL SOLAR-RADIATION; SUPPORT VECTOR MACHINE; SUNSHINE DURATION; EMPIRICAL-MODELS; URBAN SPACES; COMFORT; MICROCLIMATE; UTCI; AIR; HOT;
D O I
10.1007/s12273-024-1168-8
中图分类号
O414.1 [热力学];
学科分类号
摘要
Cities around the world are exposed to increasing heat stress as a result of the heat island effect exacerbated by extreme weather events, population growth and increased urbanization. To promote outdoor activities and protect human health, there is an urgent need for a tool to assess the outdoor thermal environment. While the air temperature (Ta) and relative humidity (RH) are usually available from weather stations, but the mean radiant temperature (MRT) cannot. The MRT is a key variable in determining outdoor thermal comfort. Therefore, it is necessary to develop a simple and accurate method for calculating MRT, in order to compute the corresponding thermal indices, which can be used to assess the thermal environment more accurately. This study was conducted at a university in Guangzhou, China. Four different ground-cover surfaces (concrete, asphalt, lawn, and granite) were selected for study. The Ta, black-globe temperature (Tg), long-wave (L), and short-wave (K) radiation in six directions, and wind speeds (Va) were measured under unshaded conditions. The MRT obtained by the six-direction integral method was used as the base value and regression analyses were performed with Ta, K down arrow (downward short-wave), and Va. In addition, the six indices-significance (P), linear regression coefficient (R2), consistency index (d), root mean square error (RMSE), mean bias error (MBE), and mean absolute error (MAE)-were used for quantitative analysis to explore the feasibility of this method. This study compared five calculation models on MRT: MRTSDIM (six-direction integral method), MRTBGTM-Va-0.1Hz (black-globe thermometer method, 0.1 Hz wind speed measurement frequency), MRTBGTM-Va-10Hz (black-globe thermometer method, 10 Hz wind speed measurement frequency), MRTBGTM-P (polynomial regression based on black-globe thermometer method), and MRTSDIM-P (polynomial regression based on six-direction integral method). The MRTSDIM was used as a baseline value, and the values obtained by other four methods were discussed and validated separately. The results show that the calculation model about MRTSDIM-P has a relatively minimal error with the values <= 5 degrees C, which satisfies the accuracy requirements for thermal stress. Finally, the data from each area weather station were substituted into the model and compared with the actual measurement days, and the monthly mean and maximum universal thermal climate index (UTCI) were calculated for the entire Guangzhou daytime in 2022. The results obtained from the weather station data calculations fit well with the measured data. Consequently, this study provides a simple method of calculation for outdoor mean radiant temperature. Further, based on the calculated thermal indices, recommendations can be provided for outdoor work and activities.
引用
收藏
页码:1989 / 2006
页数:18
相关论文
共 50 条
  • [31] Dynamic estimation of urban heat exposure for outdoor jogging: Combining individual trajectory and mean radiant temperature
    Liu, Yong
    Zhang, Guangyu
    Yang, Wei
    URBAN CLIMATE, 2024, 55
  • [32] Influence Analysis of Mean Radiant Temperature of Sky on Power Flows and Temperatures of Outdoor Electric Power Appliances
    Musalek, Lubomir
    Melichar, Jan
    Kyncl, Jan
    PROCEEDINGS OF THE 13TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2012, VOLS 1 AND 2, 2012, : 837 - 840
  • [33] Estimation of mean radiant temperature across diverse outdoor spaces: A comparative study of different modeling approaches
    Jia, Siqi
    Wang, Yuhong
    Wong, Nyuk Hien
    Tan, Chun Liang
    Chen, Shisheng
    Weng, Qihao
    Mak, Cheuk Ming
    ENERGY AND BUILDINGS, 2024, 310
  • [34] Investigating an accurate method for measuring the outdoor mean radiation temperature
    Fang, Zhaosong
    He, Huiyu
    Mao, Yudong
    Feng, Xiwen
    Zheng, Zhimin
    Guo, Zhisheng
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2023, 188
  • [35] Optimization of energy saving with adaptive setpoint temperatures by calculating the prevailing mean outdoor air temperature
    Bienvenido-Huertas, David
    Sanchez-Garcia, Daniel
    Perez-Fargallo, Alexis
    Rubio-Bellido, Carlos
    BUILDING AND ENVIRONMENT, 2020, 170
  • [36] Analysis on the impact of mean radiant temperature for the thermal comfort of underfloor air distribution systems
    Chung, Jae Dong
    Hong, Hiki
    Yoo, Hoseon
    ENERGY AND BUILDINGS, 2010, 42 (12) : 2353 - 2359
  • [37] Face Temperature as an Indicator of Thermal Stress in Outdoor Work Environments
    Hastings, Scott
    Kim, Se Woong
    Brown, Robert D.
    ATMOSPHERE, 2020, 11 (06)
  • [38] Observational studies of mean radiant temperature across different outdoor spaces under shaded conditions in densely built environment
    Lai, Alan
    Maing, Minjung
    Ng, Edward
    BUILDING AND ENVIRONMENT, 2017, 114 : 397 - 409
  • [39] On the effects of the mean radiant temperature evaluation in the assessment of thermal comfort by dynamic energy simulation tools
    Alfano, Francesca Romana d'Ambrosio
    Pepe, Daniela
    Riccio, Giuseppe
    Vio, Michele
    Palella, Boris Igor
    BUILDING AND ENVIRONMENT, 2023, 236
  • [40] An analytical thermal resistance model for calculating mean die temperature of a typical BGA packaging
    Luo, Xiaobing
    Mao, Zhangming
    Liu, Jv
    Liu, Sheng
    THERMOCHIMICA ACTA, 2011, 512 (1-2) : 208 - 216