Influence of the Outflow Graft Angular Position on the Outcomes in Patients With a Left Ventricular Assist Device

被引:0
|
作者
Zijderhand, Casper F. [1 ]
Peek, Jette J. [1 ]
Sjatskig, Jelena [1 ]
Manintveld, Olivier C. [2 ]
Bekkers, Jos A. [1 ]
Bogers, Ad J. J. C. [1 ]
Caliskan, Kadir [2 ]
机构
[1] Univ Med Ctr Rotterdam, Erasmus MC, Dept Cardiothorac Surg, Thoraxctr, Rotterdam, Netherlands
[2] Univ Med Ctr Rotterdam, Erasmus MC, Dept Cardiol, Thoraxctr, Dr Molewaterpl 40, NL-3015 GD Rotterdam, Netherlands
关键词
left ventricular assist device; mechanical circulatory support; outflow graft; thromboembolic events; CT scan; NATIVE AORTIC-VALVE; FLOW; INSUFFICIENCY; SUPPORT; FUSION;
D O I
10.1097/MAT.0000000000002189
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study aimed to explore the potential impact of the angular position of the outflow graft on thromboembolic events and aortic valve regurgitation in people with a left ventricular assist device (LVAD). We analyzed contrast computed tomography (CT) data of patients with LVAD implantation between 2016 and 2021. Three-dimensional reconstructions of the outflow graft and aortic arch were performed to calculate the horizontal (azimuth) angle and vertical (polar) angle, as well as the relative distance between the outflow graft, aortic valve, and brachiocephalic artery. Among 59 patients (median age 57, 68% male), a vertical angle >= 107 degrees correlated significantly with increased cerebrovascular accidents (hazard ratio [HR]: 5.8, 95% confidence interval [CI]: 1.3-26.3, p = 0.022) and gastrointestinal bleeding (HR: 3.4, 95% CI: 1.0-11.2, p = 0.049) during a median 25 month follow-up. No significant differences were found between the vertical angle and aortic valve regurgitation or survival. The horizontal angle and relative distance did not show differences regarding clinical adverse events. This study emphasizes the importance of the LVAD outflow graft angular position to prevent life-threatening thromboembolic events. This study suggests the need for prospective research to further validate these findings.
引用
收藏
页码:861 / 867
页数:7
相关论文
共 50 条
  • [41] Alarms and Their Outcomes in Left Ventricular Assist Device Patients
    Lim, Zi Z.
    Robson, Desiree
    Muthiah, Kavitha
    Jansz, Paul
    Macdonald, Peter S.
    Hayward, Christopher S.
    ASAIO JOURNAL, 2021, 67 (12) : 1284 - 1293
  • [42] Left Ventricular Assist Device Performance Under Pressure Troubleshooting Outflow Graft Dysfunction
    Belkin, Mark N.
    Venturini, Joseph
    Nathan, Sandeep
    Grinstein, Jonathan
    CIRCULATION-HEART FAILURE, 2020, 13 (07)
  • [43] Resolution of sudden left ventricular assist device failure due to outflow graft narrowing
    Montalto, Andrea
    Stio, Rocco
    Feccia, Mariano
    Comisso, Marina
    Pantanella, Romina
    Musumeci, Francesco
    ANNALS OF CARDIOTHORACIC SURGERY, 2021, 10 (03) : 405 - 407
  • [44] COMPLEX DECISIONS IN MANAGEMENT OF SEVERE LEFT VENTRICULAR ASSIST DEVICE OUTFLOW GRAFT OBSTRUCTION
    Cai, Janet
    Pepe, Russell
    Soliman, Fady K.
    Sunagawa, Gengo
    Takebe, Manabu
    Lemaire, Anthony
    Russo, Mark J.
    Ikegami, Hirohisa
    Grewal, Jagpreet
    Huang, Michael
    Dulnuan, Kenneth
    Iyer, Deepa Balasubramanian
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 83 (13) : 3616 - 3616
  • [45] Percutaneous endovascular stenting to treat left ventricular assist device outflow graft stenosis
    Litvak, Aaron
    Desai, Kshitij
    Narins, Craig
    Mix, Doran
    JOURNAL OF VASCULAR SURGERY CASES INNOVATIONS AND TECHNIQUES, 2024, 10 (02):
  • [46] LEFT VENTRICULAR ASSIST DEVICE OUTFLOW GRAFT STENOSIS TREATED WITH PERCUTANEOUS TRANSCATHETER STENTING
    Gilge, Jasen Lee
    Ball, Kevin
    Kelkhoff, Aaron
    Bigelow, Brian
    Ravichandran, Ashwin
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 2211 - 2211
  • [47] Left ventricular assist device outflow graft obstruction development in the original bend relief
    Kawabori, Masashi
    Nordan, Taylor
    Arkun, Knarik
    Couper, Gregory S.
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2020, 58 (06) : 1313 - 1313
  • [48] The effect of occlusive polytetrafluoroethylene outflow graft protectors in left ventricular assist device recipients
    Dimitrov, Kamen
    Kaider, Alexandra
    Granegger, Marcus
    Gross, Christoph
    Angleitner, Philipp
    Wiedemann, Dominik
    Riebandt, Julia
    Schaefer, Anne-Kristin
    Schloeglhofer, Thomas
    Laufer, Gunther
    Zimpfer, Daniel
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2022, 41 (12): : 1850 - 1857
  • [49] Left Ventricular Assist Device Implantation With Outflow Graft Tunneling Through the Transverse Sinus
    Hanke, Jasmin S.
    Rojas, Sebastian V.
    Poyanmehr, Reza
    Deniz, Ezin
    Avsar, Murat
    Berliner, Dominik
    Shrestha, Malakh
    Cebotari, Serghei
    Haverich, Axel
    Schmitto, Jan D.
    ARTIFICIAL ORGANS, 2016, 40 (06) : 610 - 612
  • [50] Outflow graft stenosis after left ventricular assist device implantation: the rotterdam experience
    Jahangiri, P.
    Sjatskig, J.
    Wilschut, J.
    Peek, J.
    Constantinescu, A.
    Manintveld, O.
    Brugts, J.
    Attrach, M.
    Budde, R. P. J.
    Kluin, J.
    Caliskan, K.
    EUROPEAN HEART JOURNAL, 2024, 45